Enersys 0800-0004

Enersys Cyclon 0800-0004 Ilana olumulo Batiri X-Cell

Awoṣe: 0800-0004

Ọrọ Iṣaaju

This manual provides essential information for the safe and effective use of the Enersys Cyclon 0800-0004 X-Cell 2 Volt/5 Amp Hour Sealed Lead Acid Battery. This pure lead sealed lead acid battery is designed for general applications such as emergency lighting, UPS systems, and electronic equipment.

Key features of the Cyclon battery include:

  • Ìwọ̀n Agbara: Offers high-rate power density per unit weight, allowing for more energy-supporting features.
  • Igbesi aye Yiyi: Provides 50% to 200% greater full cycle capability compared to competitive lead products, delivering up to 300 cycles (100% DOD, C/5).
  • Float Life: Designed for a ten-year life at 25°C, C/5, to 80% of rated capacity.
  • High Stable Voltage Delivery: Achieved through low internal resistance, providing a flat discharge voltagati profile similar to Nickel Cadmium.
  • Aabo: Emits minimal to no gassing under normal charging conditions, making it safe for installation in various environments.
Enersys Cyclon 0800-0004 X-Cell Battery

olusin 1: Iwaju view of the Enersys Cyclon 0800-0004 X-Cell battery, showing the brand name, model, and key specifications.

Diagram of Cyclon Single Cell internal design

Figure 2: Diagram illustrating the internal components of a Cyclon Single Cell, including the resealable safety valve, pure lead plates, AGM plate separator, and steel can enclosure.

Eto ati fifi sori

Proper setup is crucial for the optimal performance and longevity of your Enersys Cyclon battery. Follow these guidelines carefully:

1. Ayẹwo akọkọ

Upon receiving the battery, inspect it for any signs of physical damage. Ensure the terminals are clean and free from corrosion. Do not use the battery if it appears damaged.

2. Awọn ipo Ayika

Install the battery in a clean, dry, and well-ventilated area. Avoid locations with extreme temperatures, direct sunlight, or high humidity. The recommended operating temperature range is typically between -65°C to +80°C, but optimal performance and float life are achieved around 25°C.

3. Awọn Itọsọna Asopọmọra

Connect the battery to your equipment using appropriate cables and connectors. Ensure correct polarity: connect the positive (+) terminal of the battery to the positive terminal of your device, and the negative (-) terminal to the negative terminal. Incorrect polarity can damage the battery and connected equipment.

Oke view of Enersys Cyclon battery terminals

olusin 3: Top view of the Enersys Cyclon battery, showing the positive and negative terminals for connection.

4. Gbigba agbara akọkọ

While Cyclon batteries are shipped with a charge, it is recommended to fully charge the battery before its first use, especially if it has been stored for an extended period. Use a charger specifically designed for sealed lead-acid batteries with a 2-volt output. Refer to the charger's instructions for proper charging procedures.

Awọn ilana Iṣiṣẹ

The Enersys Cyclon battery is designed for reliable performance in various applications. Observe the following during operation:

1. Discharge Characteristics

The Cyclon battery provides a high stable voltage delivery due to its low internal resistance. This results in a flat discharge voltagati profile, ensuring consistent power output throughout its discharge cycle. Avoid deep discharges below the recommended voltage levels to maximize battery life.

2. Charging During Operation

For applications requiring continuous power, the battery can be kept on a float charge. Ensure the charging voltage is within the manufacturer's specified range for 2-volt sealed lead-acid batteries to prevent overcharging or undercharging.

3. Awọn iṣọra aabo

Although Cyclon batteries are sealed and non-spillable, always handle them with care. Do not short-circuit the terminals. Avoid exposing the battery to open flames or excessive heat. Ensure proper ventilation if the battery is enclosed, even though gassing is minimal under normal conditions.

Itoju

Enersys Cyclon batteries are maintenance-free due to their sealed, non-spillable design. However, periodic checks can help ensure optimal performance and longevity:

1. Terminal Inspection

Periodically check the battery terminals for cleanliness and tight connections. Clean any dust or dirt with a dry cloth. Do not use abrasive cleaners or solvents.

2. Ibi ipamọ

If the battery is to be stored for an extended period, ensure it is fully charged before storage. Store in a cool, dry place away from direct sunlight and extreme temperatures. Recharge the battery every 6-9 months during storage to prevent self-discharge and maintain capacity.

3. Isonu batiri

Do not dispose of the battery in household waste. Sealed lead-acid batteries contain recyclable materials and should be recycled according to local regulations. Contact your local recycling center for proper disposal instructions.

Laasigbotitusita

This section addresses common issues you might encounter with your Enersys Cyclon battery.

IsoroOwun to le FaOjutu
Batiri ko dani idiyeleUndercharging; End of life; Internal damageEnsure charger is compatible and functioning correctly. Fully charge the battery. If issue persists, battery may need replacement.
Vol kekeretage jadeBattery discharged; Loose connections; OverloadRecharge the battery. Check and tighten all connections. Ensure the load does not exceed battery capacity.
Batiri ko ngba agbaraFaulty charger; Incorrect connection; Battery faultVerify charger functionality with another battery or device. Check polarity and connections. If battery is severely discharged, it may not accept charge.

If you experience issues not listed here or if the suggested solutions do not resolve the problem, please contact Enersys customer support.

Awọn pato

Detailed specifications for the Enersys Cyclon 0800-0004 X-Cell Battery:

  • Nọmba awoṣe: 0800-0004
  • Iru Batiri: Acid Lead Didi (SLA)
  • Voltage: 2 Volts
  • Agbara: 5 Amp Awọn wakati (Ah)
  • Awọn iwọn ọja: 1.75 x 1.75 x 3.21 inches
  • Ìwọ̀n Nkan: 12.8 iwon
  • Olupese: Enerys
  • Ọjọ Akọkọ Wa: Oṣu Kẹfa Ọjọ 18, Ọdun 2004
  • Awọn lilo ti a ṣe iṣeduro: Emergency lighting, UPS systems, electronic equipment

Aabo ati Ikilọ

Please read and understand all safety warnings before handling or using the battery.

Proposition 65 Warning label on Enersys Cyclon battery

Figure 4: Warning label on the Enersys Cyclon battery, including Proposition 65 warning and other safety symbols.

Ilana 65 Ikilọ

IKILO: Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and reproductive harm. Batteries also contain other chemicals known to the State of California to cause cancer. Wash hands after handling.

Gbogbogbo Aabo Awọn iṣọra

  • Risk of fire, explosions or burns. Do not disassemble, heat above 80°C or incinerate.
  • Follow product charging instructions.
  • Do not charge in sealed container.
  • Always wear appropriate personal protective equipment (PPE) such as safety glasses and gloves when handling batteries.
  • Jeki awọn batiri kuro ni arọwọto awọn ọmọde.
  • In case of accidental contact with battery contents, flush with water immediately and seek medical attention.

Atilẹyin ọja ati Support

For warranty information, please refer to the documentation provided with your purchase or contact Enersys directly. The manufacturer's warranty typically covers defects in materials and workmanship under normal use.

Alaye olubasọrọ Olupese:

Enersys Energy Products Inc.
Warrensburg, MO 64093-9301
foonu: (610) 208-1991
Webojula: www.enersys.com

For full list of the warning and precautionary statements and applicable SDS sheet, please visit the Enersys webojula.

© 2023 Enersys. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.