1. Ifihan
Thank you for choosing the Legrand 077014 Mosaic Pull Cord Switch. This product is designed for reliable control of lighting or other electrical circuits. It features a 2-module design, rated for 10AX and 250V, and comes in a white finish. This manual provides essential information for the safe installation, operation, and maintenance of your switch.

Image of the Legrand 077014 Mosaic Pull Cord Switch, showing its white finish and pull cord mechanism.
2. Alaye Aabo
IKILO: Electrical installation should only be performed by a qualified electrician. Failure to follow these instructions can result in electric shock, fire, or serious injury.
- Always disconnect power at the main circuit breaker or fuse box before attempting any electrical work.
- Daju pe agbara wa ni pipa nipa lilo voltage tester ṣaaju ki o to kan eyikeyi onirin.
- Rii daju pe gbogbo awọn asopọ onirin wa ni aabo ati ni ibamu pẹlu awọn koodu itanna agbegbe.
- Maa ko koja volum pàtótage (250V) or current (10A) ratings of the switch.
- Pa ọja naa kuro ninu omi ati ọrinrin.
- Ọja yii jẹ ipinnu fun lilo inu ile nikan.
3. Package Awọn akoonu
Jọwọ ṣayẹwo package fun awọn nkan wọnyi:
- 1 x Legrand 077014 Mosaic Pull Cord Switch
- 1 x Cord (approximately 1.5 meters in length)
4. fifi sori
This section provides general guidance for installing the Legrand 077014 Pull Cord Switch. For detailed wiring diagrams and specific installation requirements, consult a qualified electrician and refer to local electrical codes.
4.1 Igbaradi
- Ge Agbara: Turn off the power supply to the circuit at the main breaker.
- Ṣe àyẹ̀wò Pípa Agbára: Lo voltage tester to confirm that the power is completely off at the installation site.
- Awọn irinṣẹ Kojọpọ: You will need basic electrical tools such as screwdrivers, wire strippers, and a voltage idanwo.
4.2 Wiring the Switch
The Legrand 077014 is a two-way (va-et-vient) switch, meaning it can control a light from two different locations when paired with another two-way switch. If used as a simple on/off switch, only two terminals are typically used.
- Identify the live (phase), neutral, and load wires.
- Connect the incoming live wire to the common terminal of the switch.
- Connect the outgoing wire to the light fixture (load) to one of the switching terminals.
- If used as a two-way switch, connect the traveler wires between this switch and the other two-way switch.
- Rii daju pe gbogbo awọn asopọ wa ni wiwọ ati aabo.
4.3 Iṣagbesori Yipada
- Carefully place the wired switch into the flush-mounted box or surface-mounted enclosure.
- Secure the switch using the provided screws.
- Attach the cover plate (if applicable) and ensure it is flush with the wall surface.
4.4 ik Igbesẹ
- Pada Agbara pada: Tan-an agbara pada si ẹrọ fifọ akọkọ.
- Iṣe idanwo: Test the switch by pulling the cord to ensure it operates correctly.
5. Awọn ilana Iṣiṣẹ
The Legrand 077014 Pull Cord Switch is simple to operate:
- To turn on the connected device (e.g., light), gently pull the cord downwards until you hear a click.
- To turn off the connected device, gently pull the cord downwards again until you hear a click.
- The switch operates in an alternating fashion: one pull for ON, the next pull for OFF.
6. Itọju
To ensure the longevity and proper functioning of your Legrand 077014 Pull Cord Switch, follow these simple maintenance guidelines:
- Ninu: Disconnect power before cleaning. Use a soft, dry cloth to wipe the surface of the switch. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the finish or internal components.
- Ayewo: Periodically check the cord for any signs of wear, fraying, or damage. If the cord is damaged, it should be replaced by a qualified technician.
- Avoid Over-pulling: Do not pull the cord with excessive force, as this can damage the internal mechanism.
7. Laasigbotitusita
If you encounter issues with your Legrand 077014 Pull Cord Switch, refer to the table below:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Switch does not operate (no light/power) | No power to the circuit; Loose wiring connection; Faulty bulb/device; Internal switch failure. | Check circuit breaker/fuse. Verify all wiring connections are secure (power off). Test bulb/device. If issues persist, consult a qualified electrician. |
| Cord is stuck or difficult to pull | Ìdènà tàbí ìbàjẹ́ ẹ̀rọ inú. | Do not force the cord. Disconnect power and inspect for visible obstructions. If damaged, replace the switch or consult a qualified electrician. |
| Switch makes unusual noises | Internal component wear or damage. | Disconnect power immediately. This may indicate an internal fault. Replace the switch or consult a qualified electrician. |
If you are unable to resolve the issue after following these steps, please contact Legrand customer support or a qualified electrician.
8. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Nọmba awoṣe | 077014 |
| Iru | Pull Cord Switch (Two-way / Va-et-vient) |
| Awọn modulu | 2 modulu |
| Ti won won Lọwọlọwọ | 10 AX |
| Oṣuwọn Voltage | 250 V |
| Àwọ̀ | Funfun |
| Ohun elo | Ṣiṣu |
| Awọn iwọn Ọja (L x W x H) | 9.7 x 9.7 x 5.7 cm |
| Iwọn | 40 giramu |
| Okun Gigun | 1.5 m |
| Ni ibamu Awọn alaye | NF |
| Ilu isenbale | Jẹmánì |
9. Atilẹyin ọja ati Support
Legrand products are manufactured to high-quality standards. For information regarding product warranty, please refer to the terms and conditions provided at the point of purchase or visit the official Legrand website. For technical support, spare parts, or further assistance, please contact Legrand customer service through their official channels.