1. Ifihan
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your NOVY 245999 separated chimney motor. This motor is designed for use with compatible extractor hoods, offering efficient air extraction with integrated noise reduction.
2. Alaye Aabo
- Ka gbogbo awọn itọnisọna ni pẹkipẹki ṣaaju fifi sori ẹrọ ati lo.
- Installation must be performed by a qualified technician in accordance with local regulations and electrical codes.
- Always disconnect the power supply before performing any installation, maintenance, or cleaning.
- Rii daju pe ipese itanna baamu voltage specified on the product label (230 Volt).
- Do not modify the appliance. Any modifications may void the warranty and create safety hazards.
- Jeki awọn ohun elo apoti kuro ni arọwọto awọn ọmọde.
3. Ọja Ipariview
The NOVY 245999 is a separated motor unit designed to be installed remotely from the extractor hood, contributing to quieter operation. It features a robust construction and an integrated silencer.

This image displays the NOVY 245999 separated chimney motor, a black rectangular unit with a circular exhaust port on top and electrical connections visible at the bottom. The design incorporates a silencer for reduced noise operation.
4. Eto ati fifi sori
The NOVY 245999 motor is intended for remote installation, typically in an attic, false ceiling, or an adjacent room, to minimize noise in the kitchen area. Professional installation is strongly recommended.
4.1. Iṣagbesori
- Choose a stable, vibration-free location for mounting the motor.
- Ensure adequate space around the motor for ventilation and future maintenance access.
- Secure the motor firmly using appropriate fasteners for the mounting surface.
4.2. Ducting Asopọ
- Connect the motor's inlet to the extractor hood's ducting system.
- Connect the motor's outlet to the external exhaust ducting.
- Use rigid, smooth-walled ducting with the recommended diameter to ensure optimal airflow and minimize noise.
- Ensure all ducting connections are airtight to prevent air leakage and maintain efficiency.
4.3. Asopọ Itanna
- Rí i dájú pé a ti ge agbára ìpèsè àkọ́kọ́ kúrò kí a tó ṣe àwọn ìsopọ̀ iná mànàmáná.
- Connect the motor to a dedicated electrical circuit as per local electrical codes.
- Rii daju pe voltage and frequency of the power supply match the motor's requirements (230 Volt).
- All wiring must be properly insulated and secured.
5. Awọn ilana Iṣiṣẹ
The NOVY 245999 motor is controlled via the connected extractor hood's control panel. Refer to your extractor hood's manual for specific operating instructions.
- Titan/Apapa: The motor will activate when the extractor hood is turned on.
- Eto Iyara: The motor offers 3 speed settings, which are typically selected via the extractor hood's control panel to adjust extraction power.
- Lilo to dara julọ: For best results, activate the extractor hood a few minutes before cooking and allow it to run for a short period after cooking to clear residual odors and steam.
6. Itọju
Regular maintenance ensures the longevity and optimal performance of your NOVY 245999 motor.
6.1. Ninu
- Before any cleaning, ensure the motor is disconnected from the main power supply.
- Wipe the exterior surfaces of the motor with a soft, damp asọ. Ma ṣe lo awọn afọmọ abrasive, nkanmimu, tabi awọn kẹmika lile.
- Rí i dájú pé omi kò wọ inú ilé ọkọ̀.
6.2. Ayewo
- Periodically inspect the ducting connections for any signs of leakage or damage.
- Check electrical connections for security and integrity.
- If any unusual noises or vibrations occur, disconnect power and consult a qualified technician.
7. Laasigbotitusita
Ṣaaju ki o to kan si atilẹyin alabara, tunview Awọn iṣoro ti o wọpọ ati awọn solusan wọnyi:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Mọto ko bẹrẹ | No power supply; Faulty wiring; Extractor hood control issue | Check power connection; Verify circuit breaker; Consult extractor hood manual; Contact technician |
| Reduced extraction performance | Ducting blockage; Air leakage in ducting; Incorrect speed setting | Inspect ducting for obstructions; Check ducting connections for leaks; Select higher speed setting |
| Ariwo dani tabi gbigbọn | Loose mounting; Obstruction in fan; Damaged motor component | Ensure motor is securely mounted; Disconnect power and check for obstructions; Contact technician |
8. Awọn pato
Technical data for the NOVY 245999 separated chimney motor:
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Brand | NOVY |
| Nọmba awoṣe | 245999 |
| Àwọ̀ | Dudu |
| Awọn iwọn Ọja (L x W x H) | 30.9 x 28 x 27.3 cm |
| Iwọn | 7.98 kg |
| Voltage | 230 folti |
| Nọmba ti Awọn iyara | 3 |
| Ipele Ohun | 57 Decibels |
| Olupese | NOVY |
9. Atilẹyin ọja ati Support
For warranty information, please refer to the documentation provided with your purchase or contact your retailer. For technical support or service, please contact NOVY customer service or your authorized service provider. Ensure you have your model number (245999) and proof of purchase available when seeking support.