1. Ifihan
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Schneider Electric CCT16364 Acti 9 Analog Timer. Please read these instructions carefully before use and retain them for future reference.
The CCT16364 is a 24-hour analog time switch designed for controlling electrical circuits based on a programmed schedule. It features a daily program with a maximum of 48 ON and 48 OFF switching operations.
2. Alaye Aabo
IKILO: Ewu ti ina mọnamọna
- Fifi sori ẹrọ ati itọju gbọdọ jẹ nipasẹ oṣiṣẹ ti o peye nikan.
- Disconnect power supply before installation, wiring, or maintenance.
- Rii daju pe gbogbo onirin ni ibamu pẹlu awọn koodu itanna agbegbe ati ti orilẹ-ede.
- Ma ṣe ṣiṣẹ ẹrọ ti o ba bajẹ.
- A ṣe ẹ̀rọ yìí fún lílo nínú ilé ní àwọn ibi gbígbẹ.
Ikuna lati tẹle awọn ilana wọnyi le ja si iku, ipalara nla, tabi ibajẹ ohun elo.
3. Ọja Ipariview
The Schneider Electric CCT16364 Acti 9 Analog Timer is a compact device designed for precise time-based control. Key features include:
- 24-hour analog dial for daily programming.
- Up to 48 ON and 48 OFF switching segments.
- Manual override switch.
- High measurement precision of +/- 1 second per day at 20°C.
- DIN rail mountable for easy integration into electrical panels.

olusin 1: Iwaju view of the Schneider Electric CCT16364 Acti 9 Analog Timer. Shows the 24-hour dial with segments for programming and the manual override switch.
4. Eto ati fifi sori
4.1 Iṣagbesori
The CCT16364 timer is designed for DIN rail mounting. Ensure the DIN rail is securely fastened within an appropriate enclosure.
- Hook the top edge of the timer onto the DIN rail.
- Press the bottom edge of the timer firmly until it clicks into place on the rail.
- Verify the timer is securely mounted and does not wobble.
4.2 Onirin
The timer uses pressure spring terminals for electrical connections. Refer to the wiring diagram typically found on the side or back of the device for specific connection points (e.g., L, N, Load). Ensure correct polarity and load capacity.
Note on Terminals:
The pressure spring terminals are designed for solid or stranded conductors. When using flexible cables, especially 1.5mm², termination can be challenging. Ensure the cable is properly stripped and inserted fully into the terminal for a secure connection. Ferrules may not be compatible with this terminal type.
- Connect the incoming phase (L) and neutral (N) to the designated input terminals.
- Connect the load (e.g., light, pump) to the output terminals, ensuring the timer's contact rating is not exceeded.
- Ṣàyẹ̀wò gbogbo àwọn ìsopọ̀ lẹ́ẹ̀mejì fún wíwà ní ìdúró àti títọ́ kí o tó dá agbára padà.
4.3 Aago Ibẹrẹ
After wiring and power-up, set the current time:
- Rotate the 24-hour dial clockwise until the current time aligns with the time marker (usually a small arrow or line on the housing).
- The dial typically has markings for hours and possibly 15-minute intervals.
5. Awọn ilana Iṣiṣẹ
5.1 Programming ON/OFF Periods
The 24-hour dial is surrounded by small segments. Each segment typically represents a specific time interval (e.g., 15 minutes). To program:
- Láti ṣètò àkókò ON kan: Push the segments corresponding to the desired ON time outwards towards the edge of the dial.
- Láti ṣètò àkókò PÁ: Leave the segments corresponding to the desired OFF time in their inward position.
- The timer will switch the connected load ON when the dial reaches an outward segment and OFF when it reaches an inward segment.
You can set up to 48 ON and 48 OFF switching operations within a 24-hour cycle.
5.2 Afowoyi danu
The timer includes a manual override switch, usually a small lever or button, which allows you to temporarily change the output state regardless of the programmed schedule.
- Position I (ON): Forces the output to be continuously ON.
- Position O (OFF): Forces the output to be continuously OFF.
- Automatic (Clock Symbol): Returns the timer to operate according to the programmed schedule.
Always return the switch to the automatic (clock symbol) position for scheduled operation.
6. Itọju
The Schneider Electric CCT16364 timer requires minimal maintenance.
- Ninu: Disconnect power before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
- Ayewo: Periodically inspect the wiring connections for any signs of loosening or damage. Ensure the timer is free from dust and debris.
- This device does not contain user-serviceable parts or require battery replacement.
7. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Timer not switching load ON/OFF. |
|
|
| Timer runs but load does not switch. |
|
|
| Difficulty with wiring terminals. | Pressure spring terminals can be challenging with flexible cables. | Ensure proper stripping of cable. Twist flexible strands tightly before insertion. Consider using solid core wire if possible for easier termination. |
8. Awọn pato
| Nọmba awoṣe | CCT16364 |
| Brand | Schneider Electric |
| Iru | Analog Time Switch (24H) |
| Awọn iwọn (H x W x D) | 90mm x 54mm x 66mm |
| Iwọn | 180 g |
| Itọkasi | +/- 1 s/day at 20°C |
| Max. Switching Operations | 48 NIPA / 48 PA |
| Àwọ̀ | Funfun |
| Awọn batiri ti a beere | Rara |