Beckett 7218510

Beckett 1250 GPH Submersible Water Pump Instruction Manual

Model: 7218510 | Brand: Beckett

Ọrọ Iṣaaju

This manual provides essential information for the safe and efficient operation of your Beckett 1250 GPH Submersible Water Pump. Please read these instructions carefully before installation and use. Retain this manual for future reference.

The Beckett 1250 GPH Submersible Water Pump is designed for circulating water in fountains, ponds, and waterfalls. This magnetic drive pump features a low water shut-off sensor for protection and is suitable for continuous, submerged operation. It is oil-free, making it safe for aquatic life.

Alaye Aabo pataki

WARNING: To avoid possible electric shock, special care should be taken since water is used in the use of pond equipment. For each of the following situations, do not attempt repairs yourself. Return the appliance to an authorized service facility for service or discard the appliance.

  • Ensure the pump is always fully submerged in water during operation. Running dry will damage the pump and void the warranty.
  • Ma ṣe ṣiṣẹ fifa soke ti okun tabi plug ba bajẹ.
  • Má ṣe yọ ìdènà ilẹ̀ kúrò nínú páálí agbára.
  • Máa yọ fifa omi kúrò nínú ìpèsè agbára kí o tó ṣe ìtọ́jú tàbí ìwẹ̀nùmọ́.
  • Do not lift the pump by its power cord. Use the molded handle provided.
  • This pump is designed for fresh water use only.
  • Ensure the electrical outlet is a grounded, GFCI-protected receptacle.
  • Keep children and pets away from the pump and water feature during operation.

This pump is UL Listed for electrical safety.

Package Awọn akoonu

Daju pe gbogbo awọn paati wa ṣaaju ki o to bẹrẹ fifi sori:

  • Beckett 1250 GPH Submersible Water Pump with 15 ft. power cord
  • 1-inch ID tubing adapter
Beckett 1250 GPH Submersible Water Pump with power cord and adapter

Image: The Beckett 1250 GPH Submersible Water Pump, showing the pump unit, coiled 15-foot power cord, and the included 1-inch ID tubing adapter.

Disassembled Beckett 1250 GPH Submersible Water Pump components

Aworan: Exploded view of the pump components, including the outer casing, pump body, power cord, and tubing adapter.

Eto ati fifi sori

  1. Yan Ibi: Place the pump in the deepest part of your pond or water feature, ensuring it is fully submerged. The pump is designed for continuous submerged operation.
  2. So Tubing: Connect appropriate 1-inch ID (Inner Diameter) tubing to the pump's outlet using the provided adapter. Secure the tubing with a hose clamp (not included) to prevent leaks.
  3. Ipo: Use the molded handle to carefully lower the pump into the water. Ensure the pump is stable and not resting on loose debris.
  4. Asopọmọra itanna: Route the 15-foot power cord to a grounded, GFCI-protected electrical outlet. Ensure the cord is not kinked or pinched. Do not plug in the pump until it is fully submerged.
  5. Fọfu inu omi: Ensure the water level is sufficient to completely cover the pump. The pump features a low water shut-off sensor that will prevent operation if the water level is too low.
  6. Agbara Tan: Once the pump is fully submerged and all connections are secure, plug the pump into the GFCI-protected outlet.
Diagram showing pump specifications for small waterfalls

Image: Diagram illustrating the pump's suitability for small waterfalls, indicating 1250 GPH flow, 115V, 60Hz, 50 watts power requirements, and a 15 ft cord length.

Diagram showing average performance and maximum lift for Beckett pumps

Image: Performance chart showing the relationship between pump height and flow rate, with the 1250 GPH pump (FC1200) reaching a maximum lift of 14.8 ft.

Isẹ

The Beckett 1250 GPH Submersible Water Pump is designed for continuous operation once properly installed and submerged.

  • Ibẹrẹ Ibẹrẹ: After plugging in, the pump should begin circulating water immediately. If it does not, ensure it is fully submerged and the power supply is active.
  • Low Water Shut-off: This pump is equipped with a low water shut-off sensor. If the water level drops below the safe operating threshold, the pump will automatically turn off to prevent damage. It will restart automatically once the proper water level is restored.
  • Ise Tesiwaju: For optimal performance and longevity, ensure the pump remains fully submerged and free from debris.

Itoju

Itọju deedee n ṣe idaniloju iṣẹ ṣiṣe to dara julọ ati gigun igbesi aye fifa rẹ.

  1. Ge Agbara: Máa yọ pọ́ọ̀pù kúrò nínú ihò iná mànàmáná kí o tó ṣe àtúnṣe èyíkéyìí.
  2. Clean Inlet Screen: Periodically inspect and clean the pump's inlet screen to remove any accumulated debris such as leaves, algae, or sediment. A clogged screen can reduce flow and strain the motor.
  3. Ṣe ayẹwo Impeller: If flow is reduced after cleaning the screen, the impeller may be obstructed. Carefully remove the pump casing and clean the impeller and its housing.
  4. Igba otutu: In freezing climates, remove the pump from the water feature before the first freeze. Clean the pump thoroughly and store it in a frost-free location, submerged in a bucket of water if possible, to keep seals moist.
Isalẹ view of Beckett 1250 GPH pump showing inlet screen

Aworan: Underside view of the Beckett 1250 GPH pump, highlighting the large inlet screen designed to protect against debris.

Laasigbotitusita

IsoroOwun to le FaOjutu
Pọ́ọ̀pù kì í bẹ̀rẹ̀ tàbí dúró láìròtẹ́lẹ̀.
  • No power to the pump.
  • Low water level (low water shut-off activated).
  • Clogged inlet screen or impeller.
  • Damaged impeller or motor.
  • Check power connection and GFCI outlet.
  • Add water to the feature until the pump is fully submerged and restarts.
  • Clean the inlet screen and impeller.
  • Contact customer support if pump remains inoperable after cleaning and ensuring power/water.
Dinku sisan omi.
  • Clogged inlet screen.
  • Obstruction in tubing or nozzle.
  • Debris around impeller.
  • Pump operating at too high a lift.
  • Clean the inlet screen.
  • Check and clear tubing/nozzle.
  • Nu impeller.
  • Ensure the pump is not exceeding its maximum lift capacity (14.8 ft).
Fifa ti n pariwo.
  • Idoti ni impeller.
  • Pọ́ọ̀pù náà kò ní omi pátápátá.
  • Worn impeller or bearings.
  • Nu impeller.
  • Ensure pump is fully submerged.
  • Kan si atilẹyin alabara.

Awọn pato

BrandBeckett
Nọmba awoṣe7218510
Oṣuwọn Sisan ti o pọju1250 GPH (20.83 Glọ́ọ̀nù fún ìṣẹ́jú kan)
Iwọn Gbígbé Gbígbé14.8 ft
Wattage50 Wattis
Voltage115 Volts
Igbohunsafẹfẹ60 Hz
Orisun agbaraOkun Itanna
Okun Gigun15 ft
Awọn iwọn Ọja (L x W x H)6.4" x 3.8" x 5.3"
Iwọn Nkan4.3 iwon
Ohun eloCopper 20%, Epoxy 18%, Plastic 47%, Steel 15%
Tubing Compatibility1 inch ID
Ijẹrisi aaboUL Akojọ
Comparison chart for Beckett pump models

Image: Comparison chart detailing specifications for various Beckett pump models, including the 1250 GPH (FC1200/FC1250) model.

Alaye atilẹyin ọja

Beckett Corporation products are manufactured to high-quality standards. For specific warranty details, including duration and coverage, please refer to the documentation included with your purchase or visit the official Beckett Corporation webojula. Jeki ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.

Onibara Support

If you have any questions, require technical assistance, or need to report an issue with your Beckett 1250 GPH Submersible Water Pump, please contact Beckett Corporation customer service.

For the most current contact information, please visit the official Beckett Corporation website or refer to the packaging materials.

Nigbati o ba kan si atilẹyin, jọwọ ni nọmba awoṣe rẹ (7218510) ati ọjọ rira wa.

© 2024 Beckett Corporation. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.