Ọrọ Iṣaaju
This manual provides comprehensive instructions for the installation, operation, and maintenance of the ECOELER YM2106 Wall Switch Vacancy & Occupancy Sensor. This device is designed to automatically control lighting and motor loads based on motion detection, offering energy savings and convenience. It supports both manual-on (vacancy sensor) and automatic-on (occupancy sensor) switching modes.
Alaye Aabo pataki
WARNING: RISK OF ELECTRIC SHOCK. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker before installation or servicing. Installation should be performed by a qualified electrician or in accordance with local electrical codes.
- Ka gbogbo awọn ilana ṣaaju fifi sori ẹrọ.
- Do not install with power on.
- Fun lilo inu ile nikan.
- Rii daju pe awọn asopọ waya wa ni aabo.
- Iwọn iṣẹtage: 120/277Vac, 60Hz.
- Neutral wire is not required for operation.
Package Awọn akoonu
Daju pe gbogbo awọn paati wa ṣaaju ki o to bẹrẹ fifi sori:
- ECOELER YM2106 Sensor Switch
- Awo Odi (1)
- Awọn skru
- Awọn fila onirin
- Installation Instruction Manual (this document)
Awọn pato
| Nọmba awoṣe | YM2106 |
| Voltage | 120/277Vac, 60Hz |
| Erin Awari | PIR (Infurarẹẹdi Palolo) |
| Ibora | 180-degrees; 720-square feet |
| Awọn Eto Idaduro akoko | 5 seconds to 30 minutes (adjustable) |
| Ambient Light Level | Adjustable (holds lighting off when natural light is sufficient) |
| Asopọmọra | Neutral wire not required |
| Fifuye Orisi | Incandescent, Fluorescent, LED, CFL |
| Awọn iwe-ẹri | UL Listed, Title-24 Compliant |
| Awọn iwọn | 4.12 x 1.69 x 1.75 inches |
| Ohun elo | Ṣiṣu & Irin |
Awọn ilana fifi sori ẹrọ
Ṣaaju ki o to bẹrẹ: Turn OFF power at the circuit breaker or fuse box. Ensure the power is completely disconnected before proceeding.
- Mura Waya: Carefully remove the existing wall switch from the electrical box. Identify the LINE (hot), LOAD, and GROUND wires. The ECOELER YM2106 does not require a neutral wire.
- So awọn onirin:
- Sopọ awọn okun waya dudu from the sensor to the LINE (hot) wire from the electrical box. Secure with a wiring cap.
- Sopọ awọn okun waya pupa from the sensor to the LOAD wire (to the light fixture/motor) from the electrical box. Secure with a wiring cap.
- Sopọ awọn alawọ ewe waya from the sensor to the GROUND wire from the electrical box. Secure with a wiring cap.
- Cap off any unused wires in the electrical box, such as a neutral wire, if present.
- Gbe sensọ naa: Gently fold the wires into the electrical box. Insert the sensor into the electrical box and secure it with the provided screws.
- Fi Awo Odi sori ẹrọ: Attach the decorative wall plate over the sensor and secure it.
- Pada Agbara pada: Tan-an agbara ni Circuit fifọ.
- Iṣe idanwo: The green LED indicator light on the sensor will flash when motion is detected, confirming active detection.
Note: If you are unsure about any wiring steps, consult a qualified electrician.
Isẹ
The ECOELER YM2106 sensor supports two primary modes of operation: Vacancy (Manual-On) and Occupancy (Automatic-On).
Vacancy Sensor (Manual-On) Mode
In this mode, the lights/motor will only turn ON when you manually press the switch button. Once ON, the sensor will keep the lights/motor ON as long as motion is detected within its coverage area. The lights/motor will turn OFF automatically after no motion is detected for the set time delay.
Occupancy Sensor (Automatic-On) Mode
In this mode, the lights/motor will turn ON automatically when motion is detected within the sensor's coverage area. The lights/motor will remain ON as long as motion is detected and will turn OFF automatically after no motion is detected for the set time delay.
To switch between modes or adjust settings, refer to the "Configuration and Settings" section.
Iṣeto ni ati Eto
The ECOELER YM2106 sensor features adjustable settings for time delay, sensitivity, and ambient light level. These adjustments are typically made via small dials or switches located on the sensor itself, often behind the wall plate.
- Idaduro akoko: This setting determines how long the lights/motor remain ON after the last detected motion. It is adjustable from 5 seconds to 30 minutes. Adjust clockwise for longer delays, counter-clockwise for shorter delays.
- Ifamọ: This controls the sensor's responsiveness to motion. Higher sensitivity detects smaller movements or movements at greater distances. Lower sensitivity requires more significant motion or closer proximity. Adjust as needed to prevent false triggers or missed detections.
- Ambient Light Level (Photocell): This setting allows the sensor to hold the lights/motor OFF if sufficient natural light is present in the room, even if motion is detected. This feature helps save energy by preventing artificial lighting from turning on unnecessarily. Adjust to your desired light threshold.
Consult the diagrams on the sensor unit itself for the exact location and labeling of these adjustment controls.
Itoju
- Ninu: Máa fi aṣọ rírọrùn gbẹ nu lẹ́ńsì sensọ lẹ́ẹ̀kọ̀ọ̀kan láti mú eruku tàbí ìdọ̀tí tó lè dí ìwádìí lọ́wọ́. Má ṣe lo àwọn ohun èlò ìfọmọ́ tàbí àwọn ohun èlò ìfọ́mọ́ra.
- Ayewo: Regularly check the sensor and wall plate for any signs of damage or loose connections.
- Ko si Awọn apakan Iṣẹ Olumulo: The sensor contains no user-serviceable parts. Do not attempt to open or repair the unit.
Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Lights/Motor do not turn ON. |
|
|
| Lights/Motor turn ON unexpectedly. |
|
|
| Lights/Motor turn OFF too quickly or too slowly. |
|
|
Atilẹyin ọja ati Support
For warranty information or technical support, please contact ECOELER customer service. Retain your proof of purchase for warranty claims.
Contact information is typically found on the product packaging or the manufacturer's official webojula.
Media Alaye