Ọrọ Iṣaaju
The Tripp Lite SRCOOL24K is a portable spot cooler air conditioner designed to provide 24,000 BTU/h (7 kW) of cooling capacity. This self-contained AC unit is suitable for primary cooling in small network closets, backup cooling in medium server rooms, or hot rack spot cooling in large data centers. It helps prevent equipment shutdowns and failures caused by overheating and temperature fluctuations by filtering and dehumidifying the air.
This manual provides essential information for the safe and efficient setup, operation, and maintenance of your SRCOOL24K unit.
Alaye Aabo pataki
Read all instructions before operating the unit. Failure to follow these instructions may result in property damage, serious injury, or death. Keep this manual for future reference.
- Ensure the unit is connected to a standard 208/240V 20A AC outlet with a NEMA L6-20P plug.
- Ma ṣe ṣisẹ ẹyọ naa ti okun tabi plug ba bajẹ.
- Ensure proper ventilation and exhaust routing to prevent hot air recirculation.
- This product is not for sale in California, USA.
Eto ati fifi sori
The SRCOOL24K unit is designed for easy installation and portability.
Unpacking ati ayewo
Carefully unpack the unit and inspect for any shipping damage. Retain the packaging for future transport or storage.
Awọn irinše to wa
- SRCOOL24K SmartRack 24,000 BTU 208/240V Portable Air Conditioning Unit
- 2 Gray exhaust ducts
- 2 Black cooling ducts
- 2 Exhaust duct adapters
- 2 Adjustable exhaust panels
- 4 Awọn skru ti ara ẹni
- Dual cooling duct adapter
- Louvered vent insert (preinstalled)
- 2 Drainage plugs (preinstalled)
- ENVIROSENSE environmental sensor
- SNMP configuration cable
- Itọsọna eni
Ipo
Roll the unit into place using its built-in casters. It fits into a 2 x 2-ft. (0.61 m) section of floor space. Position the unit to effectively cool the target area, such as a rack enclosure or equipment hot spot.

Figure 1: Tripp Lite SRCOOL24K Portable Air Conditioner with cooling and exhaust ducts.
Fifi sori ẹrọ iho
Attach the cooling ducts to direct cold air to specific hot spots. Use the exhaust kit to remove hot air from the room, routing it through a drop ceiling, window, or return duct. The unit includes all necessary parts for duct setup.
Asopọ agbara
Connect the 6.5-ft. (1.98 m) power cord with the NEMA L6-20P plug to a standard 208/240V 20A AC outlet.
Awọn ilana Iṣiṣẹ
The SRCOOL24K features a user-friendly control panel and advanced network management capabilities.
Ibi Iṣakoso igbimo
The unit is equipped with an easy-to-read control panel that includes a digital display and diagnostic LEDs for local management. Adjust settings such as temperature and fan speed directly from this panel.
Aifọwọyi isẹ
The SRCOOL24K supports unattended shutdown and startup, including automatic restarts after power failures, ensuring continuous operation in critical environments.
Network Management
The unit comes with a preinstalled Network Management Card (SRCOOLNET2LX) for remote monitoring and control. This card allows you to monitor temperatures, receive alerts, view logs, and adjust control settings from anywhere via SNMP, web aṣàwákiri, SSH, tabi Telnet.
An ENVIROSENSE remote sensor is included to monitor temperature and humidity up to 12-ft. (3.66 m) away, providing accurate environmental data for effective cooling management.
Itoju
The SRCOOL24K is designed for minimal maintenance.
- Fifọ́ àlẹ̀: Regularly check and clean the air filters to ensure optimal airflow and cooling efficiency. Refer to the detailed instructions in the owner's manual for filter removal and cleaning procedures.
- Ìṣàkóso Ìtútù: The built-in evaporator expels condensation through the exhaust tube, eliminating the need for a floor drain or water collection tank. Ensure the exhaust tube is clear and unobstructed.
- No Professional Maintenance Required: This unit does not require external condenser, refrigerant piping, or professional maintenance for standard operation.
Laasigbotitusita
If the unit is not operating as expected, perform the following basic checks:
- Ko si Agbara: Verify the power cord is securely plugged into a functional 208/240V 20A AC outlet. Check the circuit breaker.
- Itutu agbaiye ti ko to: Ensure all cooling and exhaust ducts are properly installed and unobstructed. Check that the air filters are clean. Verify the ambient temperature is within the unit's operating range.
- Awọn koodu aṣiṣe: Consult the owner's manual for a list of diagnostic LED codes and their corresponding troubleshooting steps.
- Titiipa eto: If the control panel is unresponsive, check if the system-lock function is enabled. This feature disables other buttons to prevent accidental input.
For persistent issues or advanced diagnostics, please contact Tripp Lite technical support.
Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Brand | TRIPP LITE |
| Nọmba awoṣe | SRCOOL24K |
| Agbara Itutu | 24,000 British Thermal Units (7 kW) |
| Voltage | 208/240 Folti |
| Orisun agbara | AC (NEMA L6-20P plug) |
| Awọn iwọn Ọja (D x W x H) | 21.7"D x 20.5"W x 38.2"H |
| Iwọn Nkan | 79550 giramu |
| Ariwo Ipele | 65 Decibels |
| Firiji | R 410A |
| Iru fifi sori ẹrọ | Gbigbe |
| Ọna Iṣakoso | App (via Network Management Card) |
| Pataki Ẹya | Portable, Network Management Card Preinstalled |
Alaye atilẹyin ọja
This Tripp Lite SRCOOL24K unit is covered by a Atilẹyin ọja fun Olupese Ọdun 1. Please refer to the warranty documentation included with your product for full terms and conditions. Keep your proof of purchase for warranty claims.
Oluranlowo lati tun nkan se
For technical assistance, troubleshooting, or warranty inquiries, please contact Eaton's expert technical support team. Support is available via phone, web, and email. Refer to the contact information provided in your product packaging or on the official Tripp Lite webojula.