Showtec Q4

Showtec Compact Par 7 Q4 7 x 3W RGBW LED Floor PAR Spot User Manual

Awoṣe: Q4

1. Ifihan

This user manual provides comprehensive instructions for the safe and efficient operation of the Showtec Compact Par 7 Q4 7 x 3W RGBW LED Floor PAR Spot. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper use and to prevent damage to the unit or injury to personnel.

The Showtec Compact Par 7 Q4 is a compact RGBW PAR can designed for various lighting applications, offering versatile color mixing and robust performance.

2. Awọn ilana aabo

Máa tẹ̀lé àwọn ìlànà ààbò wọ̀nyí láti dín ewu ìkọlù iná mànàmáná, iná, tàbí ìpalára kù:

  • Rii daju pe ipese agbara voltage ibaamu awọn voltage pato lori kuro.
  • Nigbagbogbo so ẹrọ pọ mọ iṣan agbara ti ilẹ.
  • Ma ṣe ṣiṣẹ ẹyọ naa ti okun ba bajẹ.
  • Disconnect from mains power before cleaning or servicing.
  • Ma ṣe fi ẹrọ naa han si ojo tabi ọrinrin.
  • Maintain adequate ventilation around the unit to prevent overheating.
  • Yago fun ifihan oju taara si orisun ina.
  • Ẹyọ yii wa fun lilo inu ile nikan.

3. Ọja Ipariview

The Showtec Compact Par 7 Q4 features seven 3W RGBW LEDs, providing a wide spectrum of colors. Its compact design makes it suitable for floor standing or truss mounting.

Showtec Compact Par 7 Q4 with red lights

olusin 3.1: Iwaju view of the Showtec Compact Par 7 Q4 with red light output, showcasing its seven powerful RGBW LEDs.

Showtec Compact Par 7 Q4 with white lights

Figure 3.2: The PAR spot emitting a bright white light, demonstrating its full spectrum capabilities.

Showtec Compact Par 7 Q4 with blue lights

Figure 3.3: The PAR spot displaying a vibrant blue light, highlighting its color mixing versatility.

Showtec Compact Par 7 Q4 LEDs off

olusin 3.4: Isunmọ view of the LED array when the unit is off, showing the individual lenses.

Showtec Compact Par 7 Q4 rear view pẹlu awọn asopọ

olusin 3.5: Ẹyìn view of the unit, showing the power input and DMX connections (XLR 3-pin).

Showtec Compact Par 7 Q4 angled view pẹlu imurasilẹ

olusin 3.6: Angled view of the PAR spot, demonstrating the adjustable mounting bracket for floor or truss applications.

4. Eto

4.1 Ṣiṣii silẹ

Carefully unpack the unit and check for any damage during transit. Retain the packaging material for future transport or storage.

4.2 Iṣagbesori

The Compact Par 7 Q4 can be used as a floor spot or mounted to a truss using the integrated bracket. Ensure the mounting surface or truss can support the weight of the fixture. Use appropriate clamps and safety cables when mounting overhead.

4.3 Asopọ agbara

Connect the power cable to the unit's power input and then to a grounded electrical outlet. Verify that the local voltage ibaamu awọn kuro ká ibeere (240 Volts).

4.4 DMX Asopọ (Aṣayan)

For DMX control, connect a DMX cable from your DMX controller to the DMX IN port of the fixture. If connecting multiple units, daisy-chain them by connecting the DMX OUT of the first unit to the DMX IN of the next.

5. Ṣiṣẹ

5.1 Iṣakoso igbimo

The unit features a digital display and control buttons (Menu, Up, Down, Enter) on the rear for setting modes and DMX addresses.

5.2 Awọn ọna ṣiṣe

The Showtec Compact Par 7 Q4 typically offers several operating modes:

  • Ipo DMX: Allows control via an external DMX controller. Set the DMX address using the control panel.
  • Ipo Aifọwọyi: Pre-programmed light shows that run automatically.
  • Ipo Nṣiṣẹ Ohun: The light reacts to sound via a built-in microphone.
  • Ọga/Ipo Ẹrú: Link multiple units where one acts as the master and others as slaves, synchronizing their operation.
  • Ipo Awọ Aimi: Select and display a single static color.

5.3 DMX ikanni Chart

Refer to the specific DMX channel chart in the full product manual for detailed information on controlling each function via DMX. Common channels include Dimmer, Red, Green, Blue, White, Strobe, and Program selection.

6. Itọju

6.1 Ninu

Regular cleaning of the lenses and housing is recommended to maintain optimal light output and extend the unit's lifespan. Use a soft, lint-free cloth and a mild glass cleaner. Do not use abrasive materials.

6.2 Fiusi Rirọpo

If the unit does not power on, check the fuse located near the power input. Replace it with a fuse of the same type and rating only.

6.3 Ibi ipamọ

When not in use, store the unit in its original packaging or a suitable flight case in a dry, dust-free environment.

7. Laasigbotitusita

IsoroOwun to le FaOjutu
Unit ko ni agbara loriNo power supply; Blown fuse; Damaged power cableCheck power connection; Replace fuse; Replace cable
Ko si iṣakoso DMXIncorrect DMX address; Faulty DMX cable; DMX controller issueVerify DMX address; Check/replace DMX cable; Test controller
Àwọn ìmọ́lẹ̀ ń tàn tàbí ń hùwà láìṣeéṣePoor DMX signal; Overheating; Internal faultCheck DMX connections; Ensure proper ventilation; Contact support
Awọn awọ jẹ ti ko tọIncorrect DMX channel values; Internal calibration issueAdjust DMX values; Perform factory reset if available; Contact support

8. Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
BrandShowtec
AwoṣeQ4
Nọmba itọkasiLIG0013729-000
Orisun Imọlẹ7 x 3W RGBW LED
Agbara3 Watts (per LED)
Voltage240 Volts
Orisun agbaraCable ina
Awọn iwọn (L x W x H)31.5 x 31 x 15.5 cm
Iwọn2.73 kilo
ASINB01F04U758

9. Atilẹyin ọja ati Support

Information regarding specific warranty terms and conditions for the Showtec Compact Par 7 Q4 is not available in the provided product details. Please refer to the retailer or manufacturer's official webAaye fun alaye atilẹyin ọja ti o pọ julọ si-ọjọ.

For technical support, service, or spare parts inquiries, please contact your authorized Showtec dealer or the manufacturer directly. Always provide the model number (Q4) and reference number (LIG0013729-000) when seeking support.

© 2024 Showtec. All rights reserved.

Afowoyi yii le yipada laisi akiyesi.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.