BMC E-20A-H

BMC RESmart GII Auto CPAP E-20A-H with Humidifier User Manual

Model: E-20A-H

1. Ifihan

This manual provides essential information for the safe and effective operation, setup, and maintenance of your BMC RESmart GII Auto CPAP System E-20A-H with Humidifier. Please read this manual thoroughly before using the device and retain it for future reference. This device is intended for the treatment of Obstructive Sleep Apnea (OSA).

2. Alaye Aabo

Awọn ikilọ Abo pataki:

  • Always disconnect the device from the power supply before cleaning or performing any maintenance.
  • Ma ṣe fi ẹrọ naa bọ omi tabi omi miiran.
  • Use only accessories and parts recommended by BMC.
  • Keep the device away from direct sunlight, heat sources, and sharp objects.
  • Consult your physician or healthcare provider if you experience any unusual symptoms or discomfort during use.
  • Ẹrọ yii kii ṣe ipinnu fun atilẹyin igbesi aye.

3. Ọja Ipariview

The BMC RESmart GII Auto CPAP System E-20A-H is an intelligent device designed for the treatment of Obstructive Sleep Apnea. It features an integrated humidifier for enhanced comfort.

Awọn eroja pataki:

  • Ẹka akọkọ: Houses the motor, control electronics, and display.
  • Ọririnrin: Integrated unit with dual water chambers for efficient humidification.
  • Ifihan LCD 3.5-inch: Provides real-time information and access to settings.
  • Iṣakoso Knob: Fun awọn akojọ aṣayan lilọ kiri ati ṣatunṣe eto.
  • Oju-afẹfẹ: Connects to the CPAP tubing.
  • Iwọle agbara: Fun sisopọ ohun ti nmu badọgba agbara.
  • Iho kaadi SD: For compliance data storage and retrieval (iCode II).
  • SpO2 Kit Port (Optional): For real-time blood oxygen saturation and pulse rate monitoring.
BMC RESmart GII Auto CPAP System with Humidifier

An image showing the BMC RESmart GII Auto CPAP device, featuring its main unit, control knob, and integrated humidifier. The device is black with a clear humidifier chamber visible.

4. Eto

4.1 Ṣiṣii silẹ

  1. Ni ifarabalẹ yọ gbogbo awọn paati kuro ninu apoti.
  2. Inspect the device and accessories for any signs of damage. Do not use if damaged.

4.2 Nsopọ Agbara

  1. Connect the power adapter to the power inlet on the back of the device.
  2. Pulọọgi okun agbara sinu iṣan itanna to dara.

4.3 Filling the Humidifier

  1. Open the humidifier chamber by sliding or lifting the cover.
  2. Fill the water chamber with distilled water up to the maximum fill line. Do not overfill.
  3. Pa iyẹwu humidifier naa ni aabo.

4.4 Connecting Tubing and Mask

  1. Connect one end of the CPAP tubing to the air outlet on the device.
  2. Connect the other end of the tubing to your prescribed CPAP mask.
  3. Fit the mask comfortably and securely according to its own instructions.

5. Awọn ilana Iṣiṣẹ

5.1 Starting Therapy

  1. Ensure the device is properly set up and connected.
  2. Fi boju-boju rẹ wọ.
  3. Press the Start/Stop button (usually the control knob) to begin therapy. The device will automatically start delivering air.

5.2 Siṣàtúnṣe Eto

Use the control knob to navigate the menu on the 3.5-inch LCD display. Press the knob to select an option and rotate to adjust values.

  • Ibiti titẹ: 4-20 cm H2O (Auto CPAP adjusts automatically within this range).
  • Ramp Àkókò: Adjusts the time (0-60 minutes) for the pressure to gradually increase to the prescribed level.
  • Humidification Level: Select from Off or levels 1-5 to control the humidity output.
  • Reslex: Pressure relief feature (Off/1/2/3) for exhalation comfort.
  • Tan/Pa a laifọwọyi: Can be enabled or disabled (Off by default).

5.3 Stopping Therapy

Press the Start/Stop button again to end therapy. The device will power down.

5.4 iCode II Data Retrieval

Compliance data is encoded by a QR code displayed on the device's screen. Use a compatible application to scan the QR code for quick data retrieval and monitoring.

6. Itọju

Regular cleaning and maintenance are crucial for the optimal performance and longevity of your device.

6.1 Daily Cleaning

  • Humidifier Water Chamber: Empty any remaining water and rinse with distilled water. Allow to air dry.
  • Boju: Wipe down the mask cushion with a damp cloth or specialized CPAP wipes.

6.2 osẹ Cleaning

  • Humidifier Water Chamber: Wash with mild soap and warm water. Rinse thoroughly and allow to air dry completely.
  • CPAP Tubing: Wash with mild soap and warm water. Rinse thoroughly and hang to air dry.
  • Asẹ afẹfẹ: Inspect the reusable air filter (if applicable). If dirty, rinse under running water and allow to air dry. Replace disposable filters as recommended.

6.3 Itọju Gbogbogbo

  • Mu ese ita ti ẹrọ naa pẹlu ipolowoamp cloth. Do not use abrasive cleaners or immerse the device.
  • Replace air filters regularly as per manufacturer recommendations or if visibly dirty.

7. Laasigbotitusita

Ti o ba pade awọn ọran, tọka si awọn iṣoro ti o wọpọ ati awọn ojutu wọnyi:

IsoroOwun to le FaOjutu
Ko si agbaraA ti ge okùn agbara kuro; A ti ge agbara outageCheck power connections; Restore power supply
Air leak from maskMask not fitted correctly; Mask worn outAdjust mask straps; Replace mask cushion or mask
Dry mouth/throatHumidifier off or set too low; Water chamber emptyIncrease humidification level; Refill water chamber
Ohun elo jẹ alariwoAir filter dirty or blocked; Device on an uneven surfaceClean or replace air filter; Place device on a stable, flat surface
Pressure feels too high/lowIncorrect pressure setting; Ramp feature activeConsult your physician for pressure adjustments; Wait for ramp lati pari

If the problem persists, contact your healthcare provider or the manufacturer's customer support.

8. Awọn pato

Ẹya ara ẹrọSipesifikesonu
AwoṣeE-20A-H
IpoCPAP / Auto
Ibiti titẹ4-20 cm H2O
Pressure Increment0.5 cm H2O
Ramp Akoko0-60 iṣẹju
ReslexPaa / 1/2/3
Ipele Ohun<30 dBA
Awọn Ipele RirọPaa / 1-5
Ifihan3.5-inch LCD
Awọn iwọn (LxWxH)170x196x118mm (device) / 290x196x134mm (with H60 humidifier)
Iwọn<1.5kg (device) / <2.5kg (with H60 humidifier)
Ibi ti ina elekitiriki ti nwaInput Range 100-240V AC, 50/60 Hz, 2.0 A max
Ibi ipamọ dataSD Card (iCode II)
Ilu isenbaleChina

9. Atilẹyin ọja ati Support

For warranty information, please refer to the documentation provided with your purchase or contact your retailer. For technical support, service, or questions regarding your BMC RESmart GII Auto CPAP System, please contact the seller or the manufacturer directly.

© 2023 BMC. All rights reserved. This manual is for informational purposes only.