1. Ifihan
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Gree Multi21+ Dual-Zone Mini Split Air Conditioner Heat Pump. Please read this manual thoroughly before using the unit and retain it for future reference. Proper installation by a state-licensed HVAC contractor is required to ensure warranty validity and safe operation.
The Gree Multi21+ Dual-Zone VIREO 24,000 BTU System is designed to provide both heating and cooling for two separate zones without the need for distribution boxes. It features Gree's G10 inverter-driven compressor and utilizes eco-friendly R410A refrigerant.

Figure 1.1: Dual-zone cooling and heating capability.
2. Alaye Aabo
Nigbagbogbo faramọ awọn iṣọra ailewu atẹle lati ṣe idiwọ ipalara tabi ibajẹ si ẹyọ naa.
- Fifi sori Ọjọgbọn: Installation, maintenance, and repair must be performed by a qualified, state-licensed HVAC technician. Improper installation can lead to electric shock, fire, water leakage, or other hazards.
- Aabo Itanna: Ensure the power supply matches the unit's specifications. Do not operate the unit with wet hands. Disconnect power before any cleaning or maintenance.
- Firiji: The unit uses R410A refrigerant. Do not attempt to handle refrigerant yourself. Contact a qualified technician for any refrigerant-related issues.
- Awọn ifọmọ: Maintain adequate clearances around the indoor and outdoor units for proper airflow and service access.
- Awọn ọmọde ati awọn ohun ọsin: Pa awọn ọmọde ati awọn ohun ọsin kuro ni ẹyọkan, paapaa lakoko iṣẹ ati itọju.
- Awọn ohun elo ina: Má ṣe gbé àwọn ohun èlò tí ó lè jóná tàbí àwọn aerosols sí ẹ̀gbẹ́ ohun èlò náà.
3. Ọja Ipariview
3.1 irinše
The Gree Multi21+ system consists of:
- Ẹrọ ita gbangba: The condenser unit responsible for heat exchange.
- Indoor Units (2): Wall-mounted units that deliver conditioned air to each zone.
- Isakoṣo latọna jijin: For convenient operation of the indoor units.

Figure 3.1: Indoor unit and remote control.
3.2 Key Awọn ẹya ara ẹrọ
- Imọ-ẹrọ Inverter G10: Saves energy, reduces outdoor noise, and maintains stable room temperature by eliminating frequent starts and stops.
- Agbára Agbègbè Méjì: Heats and cools two separate areas independently.
- Firiiji ti o ni ore ayika: Uses R410A refrigerant.
- Agbara Wi-Fi: An optional field-installed Wi-Fi kit (sold separately) allows remote control via a smartphone.
- Apẹrẹ Iwapọ: Wall-mounted indoor units blend with various decors.

Figure 3.2: Product feature icons.
4. Eto ati fifi sori
Pataki: Installation of this Gree Multi21+ system must be performed by a state-licensed HVAC contractor. Failure to do so will void the manufacturer's warranty and may result in unsafe operation.
4.1 Pre-Fifi awọn ibeere
- Line Sets: The system requires specific line sets, which are not included. You will need one 1/4" x 3/8" line set and one 1/4" x 1/2" line set.
- Ipese Itanna: Ensure a dedicated 208/230V electrical circuit is available and properly sized for the unit.
- Ibi Igbesoke: Select appropriate locations for both indoor and outdoor units, considering clearances, drainage, and structural support.
4.2 Wi-Fi Module Installation (Optional)
The unit is Wi-Fi capable. A field-installed Wi-Fi kit accessory is sold separately. Refer to the instructions provided with the Wi-Fi kit for installation and setup procedures. Once installed, this allows for remote control of the unit via a smartphone application.
5. Awọn ilana Iṣiṣẹ
The unit is primarily controlled using the wireless remote control. Ensure the remote has fresh batteries and is pointed towards the indoor unit when sending commands.
5.1 Latọna Iṣakoso Awọn iṣẹ

olusin 5.1: Alailowaya isakoṣo latọna jijin.
- Bọtini TAN/PA: Ṣe agbara ẹrọ naa tan tabi pa.
- Bọtini MODE: Awọn iyipo nipasẹ awọn ipo iṣẹ: Aifọwọyi, Itura, Gbẹ, Ooru, Fan.
- Awọn Bọtini Iṣatunṣe iwọn otutu (▲/▼): Ṣe alekun tabi dinku iwọn otutu ti a ṣeto.
- Bọtini FAN: Ṣe atunṣe iyara àìpẹ (Aifọwọyi, Kekere, Alabọde, Ga).
- Bọtini SWING: Controls the louver's vertical swing direction.
- Bọtini Orun: Activates sleep mode for energy-saving and quiet operation during sleep.
- Bọtini TURBO: Ó ń mú kí ìtútù tàbí ìgbóná yára ṣiṣẹ́ fún ìgbà díẹ̀.
- Bọtini Imọlẹ: Turns the indoor unit's display light on or off.
- Bọtini TIMER: Ó ń ṣètò aago tí a ó máa fi tan/pa.
5.2 Awọn ọna ṣiṣe
- Ipo Itura: Fun itutu agbaiye yara. Ṣeto iwọn otutu ti o fẹ ati iyara afẹfẹ.
- Ipo Ooru: Fun alapapo yara. Ṣeto iwọn otutu ti o fẹ ati iyara afẹfẹ.
- Ipo gbigbẹ: Din ọriniinitutu ninu yara.
- Ipo Ipele: Circulates air lai alapapo tabi itutu.
- Ipo Aifọwọyi: The unit automatically selects the operating mode (Cool, Heat, Fan) based on the room temperature and the set temperature.
6. Itọju
Regular maintenance ensures optimal performance and longevity of your unit. Always disconnect power before performing any maintenance.
6.1 Air Filter Cleaning
Clean the air filters every two weeks, or more frequently depending on usage and air quality.
- Ṣii iwaju iwaju ti ẹyọ inu inu.
- Yọ awọn asẹ afẹfẹ kuro.
- Fọ àwọn àlẹ̀mọ́ pẹ̀lú ẹ̀rọ ìfọṣọ tàbí kí o fi omi gbígbóná àti ọṣẹ díẹ̀ fọ̀ wọ́n.
- Jẹ́ kí àwọn àlẹ̀mọ́ gbẹ pátápátá kí o tó tún fi kún un.
- Pa nronu iwaju ni aabo.
6.2 Ìmọ́tótó Ẹ̀yà Ìta
Periodically check the outdoor unit for debris, leaves, or obstructions around the coils and fan. Gently clean with a soft brush or vacuum. Do not spray water directly onto electrical components.
6.3 Ọjọgbọn Iṣẹ
It is recommended to have a qualified HVAC technician perform an annual inspection and professional cleaning of the entire system.
7. Laasigbotitusita
Ṣaaju ki o to kan si iṣẹ, tunview awọn wọnyi wọpọ oran ati awọn solusan.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹka ko ṣiṣẹ | Ko si ipese agbara Remote control batteries low Iṣẹ aago ṣiṣẹ | Ṣayẹwo Circuit fifọ Rọpo awọn batiri Fagilee eto aago |
| Insufficient itutu / alapapo | Dirty air filters Àwọn fèrèsé/ìlẹ̀kùn ṣí sílẹ̀ Eto iwọn otutu ko tọ Outdoor unit obstructed | Mọ air Ajọ Pa awọn window/awọn ilẹkun Ṣatunṣe iwọn otutu Ko awọn idena kuro |
| Ariwo ti ko wọpọ | Awọn ẹya alaimuṣinṣin Idilọwọ àìpẹ | Contact HVAC technician Check for obstructions (after disconnecting power) |
| Omi jijo lati inu ile kuro | Clogged drain pipe Aibojumu fifi sori | Contact HVAC technician |
If the problem persists after attempting these solutions, please contact a qualified HVAC technician for assistance.
8. Awọn pato
Key technical specifications for the Gree Multi21+ Dual-Zone Mini Split System (Model: MULTI24CVIR201).
- Brand: GREE
- Orukọ awoṣe: MULTI24CVIR201 4000
- Nọmba awoṣe: MULTI24CVIR201
- Agbara: 2 Toonu (24,000 BTU)
- Agbara Itutu: 24,000 British gbona sipo
- Ipin Imuṣiṣẹ Agbara Igba Igba (SEER): 21.2
- Voltage: 230 Volts
- Ipele Ariwo: 56 Decibels (Outdoor Unit)
- Firiji: R 410A
- Okunfa Fọọmu: Mini-Pipin
- Iyipada oluyipada: Has Inverter (G10 Inverter Technology)
- Iru fifi sori ẹrọ: Pin System
- Oriṣi Kọnpiresi: Rotary Scroll
- Outdoor Unit Required: Bẹẹni
- Ọna Iṣakoso: Isakoṣo latọna jijin
- UPC: 841999166618
- GTIN: 841999166618
8.1 Unit Mefa

Figure 8.1: Vireo+ Multi Indoor and Outdoor Unit Measurements.
9. atilẹyin ọja Information
The manufacturer's warranty terms for this Gree Multi21+ system are:
- Awọn ẹya: 5 Odun Atilẹyin ọja Lopin
- Kompasio: 7 Odun Atilẹyin ọja Lopin
Akiyesi pataki: To be eligible for the warranty, installation must be performed by a state-licensed HVAC contractor. Any damage or malfunction resulting from improper installation or unauthorized service will void the warranty.
10. Atilẹyin
For technical assistance, warranty claims, or service inquiries, please contact your installing HVAC contractor or the Gree customer support directly. Ensure you have your model number (MULTI24CVIR201) and purchase date available when contacting support.
For additional resources and product information, you may visit the official GREE website or consult the documentation provided by your installer.