1. Ifihan
This manual provides detailed instructions for the installation, operation, and maintenance of the Sure-Lites CU2-LED Integrated LED Emergency Light. This unit is designed to provide reliable emergency illumination in various commercial and industrial settings.
Figure 1: Sure-Lites CU2-LED Emergency Light, front view. This image shows the compact, white housing of the emergency light with its two integrated LED light heads.
Awọn ẹya pataki:
- Reliable Emergency Lighting: Equipped with long-life LEDs and proprietary optics for optimal illumination during power outages.
- Fifi sori Rọrun: Features a patented EZ Hang design for quick and simplified mounting, reducing installation time.
- Advanced Circuitry: Includes dual voltage AC input (120/277V), a brownout circuit, low voltage disconnect, and overload/short circuit protection.
- Apẹrẹ ti o tọ: Constructed from injection-molded, color-stable, high-impact thermoplastic, suitable for both ceiling and wall mount applications.
- Nickel-Cadmium Battery: Integrated sealed nickel-cadmium battery provides backup power.
- Ibamu: UL924 listed and compliant with most state and local codes, including Damp Location, Life Safety NFPA 101, and NEC/OSHA.
2. Awọn Ilana Aabo pataki
ÌKÌLỌ̀: Ewu ìkọlù iná mànàmáná. Yọ agbára kúrò kí o tó fi sori ẹrọ tàbí kí o ṣe iṣẹ́.
- Read all instructions carefully before installing or servicing this fixture.
- Ensure the main power supply is disconnected at the fuse or circuit breaker before installation or maintenance.
- Fifi sori ẹrọ ati iṣẹ yẹ ki o ṣe nipasẹ oṣiṣẹ ti o peye nikan.
- Maṣe gbe soke nitosi gaasi tabi awọn igbona ina.
- Do not use outdoors. This unit is designed for indoor use in damp awọn ipo.
- Ma ṣe jẹ ki awọn okun ipese agbara fi ọwọ kan awọn aaye ti o gbona.
- Do not block the light output of the LED heads.
- The battery is a sealed nickel-cadmium type. Do not attempt to open or replace with non-approved batteries.
- Ensure all connections are secure and correct to prevent fire or electric shock.
3. Awọn ilana fifi sori ẹrọ
3.1 Unpacking ati ayewo
Carefully unpack the fixture and inspect for any damage. Retain all packing materials in case of return. Ensure all components listed in the packaging are present.
3.2 Iṣagbesori Location
Select a suitable mounting location on a wall or ceiling. The unit is designed for universal J-box mounting patterns and includes keyhole mounting slots. Ensure the location allows for proper illumination of the egress path.
Figure 2: Dimensions of the CU2-LED Emergency Light. The diagram shows the unit's length as 11 1/8 inches (282.6mm), width as 1 3/4 inches (45.0mm), and height as 5 3/8 inches (136.6mm).
3.3 Mounting the Back Plate
- Disconnect AC power to the junction box.
- Separate the front housing from the back plate. The unit is delivered with the mounting plate installed. Use a flat blade screwdriver in the designated slots to carefully pry open the unit.
- Position the back plate over the junction box. The back plate has multiple pre-drilled holes to accommodate various junction box configurations. Select the appropriate holes that align with your junction box.
- Secure the back plate to the junction box using appropriate screws (not included, typically provided with the junction box). Ensure the back plate is firmly attached to prevent movement.
- For hands-free wiring, utilize the EZ Hang feature. The back plate includes a tab and slot mechanism. Carefully insert the tab from the front housing into the corresponding slot on the back plate. This allows the front housing to hang while electrical connections are made.
olusin 3: Ti abẹnu view of the CU2-LED Emergency Light showing wiring and battery. This image displays the circuit board, battery pack, and wiring connections, including the 120VAC input wire.
3.4 Electrical Awọn isopọ
The unit supports dual voltage AC input (120V or 277V). Identify the correct voltage fun fifi sori rẹ.
- Sopọ awọn DUDU waya lati imuduro si awọn 120V AC LINE waya.
- Sopọ awọn ỌSAN waya lati imuduro si awọn 277V AC LINE waya.
- Sopọ awọn FUNFUN waya lati imuduro si awọn ADODO waya.
- Rii daju didasilẹ to dara ni ibamu si awọn koodu itanna agbegbe.
- Use appropriate wire nuts for all connections. Ensure connections are tight and secure.
- After wiring, connect the battery pack to the circuit board. The battery connector is typically a small plug that fits into a corresponding receptacle on the PCB. Ensure it is fully seated.
IMPORTANT: Do not connect both 120V and 277V line wires simultaneously. Cap off the unused line wire with a wire nut.
3.5 ik Apejọ
- Once all electrical connections are made and the battery is connected, carefully tuck all wires into the junction box.
- Align the front housing with the mounted back plate. Gently push the front housing onto the back plate until it snaps securely into place. Ensure there are no gaps between the housing and the mounting surface.
- Restore AC power to the circuit. The charge indicator light (usually an LED on the unit's housing) should illuminate, indicating the battery is charging.
4. Isẹ
4.1 Isẹ ibẹrẹ
Upon initial power-up, allow the unit to charge for a minimum of 24 hours before conducting any tests. This ensures the nickel-cadmium battery reaches its full capacity.
4.2 Iṣiṣẹ Aifọwọyi
The Sure-Lites CU2-LED Emergency Light is designed for automatic operation. When AC power is present, the unit's battery will charge, and the LED heads will remain off. In the event of an AC power failure or a significant voltage drop (brownout circuit activation), the unit will automatically switch to battery backup, illuminating the LED heads to provide emergency lighting.
Awọn kekere voltage disconnect feature protects the battery from deep discharge, extending its lifespan.
4.3 Bọtini idanwo
A test button is located on the unit's housing. Pressing and holding this button simulates an AC power failure, causing the LED heads to illuminate (if the battery is charged). Release the button to return to normal operation. This button is used for routine testing.
5. Itọju
5.1 Routine Testing
Regular testing is crucial to ensure the emergency light functions correctly during an actual power outage. Follow these guidelines:
- Oṣooṣu: Press the test button for at least 30 seconds. The LED heads should illuminate. Release the button; the LED heads should turn off, and the charge indicator should remain lit.
- Ọdọọdún: Disconnect AC power to the unit for a full 90 minutes. The LED heads should remain illuminated for the entire duration. Reconnect AC power; the LED heads should turn off, and the charge indicator should remain lit.
Keep a record of all tests for compliance purposes.
5.2 batiri Alaye
The unit contains a sealed nickel-cadmium battery. This battery requires a full recharge time of 24 hours (max.) at 120/277V or 48 hours at 240V after a discharge event. The battery is designed for long life but will eventually require replacement.
WARNING: Battery replacement should only be performed by qualified service personnel. Use only approved replacement batteries from Sure-Lites to ensure proper operation and safety.
To access the battery for replacement, the front housing must be carefully separated from the back plate using a flat blade screwdriver in the designated slots, similar to the initial installation process. Exercise caution to avoid damaging internal components.
5.3 Ninu
Clean the exterior of the unit periodically with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the housing.
6. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| LED heads do not illuminate during a power outage or when test button is pressed. |
|
|
| Ina Atọka gbigba agbara wa ni pipa. |
|
|
| LED heads blink when test button is pressed, but do not stay on. |
|
|
| Unit does not snap securely onto mounting plate. |
|
|
7. Awọn pato
| Nọmba awoṣe | CU2-LED |
| Brand | Daju-Lites |
| Orisun Imọlẹ | LED ti a ṣepọ |
| Voltage | 120/277 Volts AC (Dual Voltage) |
| Batiri Iru | Sealed Nickel-Cadmium (Ni-Cd) |
| Igba Tunse | 24 hours (max.) at 120/277V; 48 hours at 240V |
| Ohun elo | High-impact Thermoplastic |
| Àwọ̀ | Funfun |
| Iṣagbesori Iru | Oke odi, Oke Oke |
| Awọn iwọn (L x W x H) | 11.13" x 1.75" x 5.37" (282.6mm x 45.0mm x 136.6mm) |
| Iwọn | 1.21 iwon |
| Awọn iwe-ẹri | UL924 Listed, Damp Location, NFPA 101, NEC/OSHA Compliant |
| Olupese | Eaton Lighting Division |
8. atilẹyin ọja Information
The Sure-Lites CU2-LED Emergency Light comes with a five-year limited warranty from the manufacturer, Eaton Lighting Division. This warranty covers defects in materials and workmanship under normal use and service.
For specific warranty terms, conditions, and claim procedures, please refer to the official warranty documentation provided with your product or contact Sure-Lites customer support.
9. Onibara Support
If you encounter any issues or have questions regarding the installation, operation, or maintenance of your Sure-Lites CU2-LED Emergency Light that are not covered in this manual, please contact Sure-Lites customer support or visit their official webaaye fun iranlọwọ siwaju sii.
For the most up-to-date contact information, please refer to the product packaging or the Sure-Lites official webojula.
Awọn orisun Ayelujara: Visit the Sure-Lites Store on Amazon