This manual provides detailed instructions for the Keenso 2-Channel Relay Module. This module is designed for controlling various electrical devices with a low-level trigger signal, making it suitable for integration with microcontrollers like Arduino, Raspberry Pi, 8051, AVR, PIC, DSP, ARM, and MSP430. It features optocoupler isolation for stable performance and offers flexible voltage awọn aṣayan.

Aworan 1.1: Pariview of the Keenso 2-Channel Relay Module.
2. Awọn ẹya Ọja
- Humanized Interface Design: All interfaces can be directly connected via terminal cables for convenience.
- Fifi sori Rọrun: Equipped with four fixed screw holes for simple mounting.
- Microcontroller Compatibility: Standard interface directly controllable by microcontrollers (e.g., Arduino, Raspberry Pi, 8051, AVR, PIC, DSP, ARM, MSP430, TTL logic).
- Iṣe Iduroṣinṣin: Utilizes high-quality relays with normal interface and a maximum load of AC 250V/10A, DC 30V/10A.
- Optocoupler Isolation: SMT optocoupler isolation provides strong driving capability and stable performance.
- Low Trigger Current: Trigger current is 5mA.
- Flexible Trigger Levels: Modules can be activated by setting high or low levels via jumpers.
- Error-Tolerant Design: Ensures the relay remains stable even if the control line is interrupted.
- Awọn Atọka Ipo Features a green power indicator and two red relay status indicators.
- Ọpọ Voltage Awọn aṣayan: Available in 5V, 12V, and 24V operating voltages.
- Iwapọ ati Gbẹkẹle: Designed for easy integration into projects with high-quality components for reliable and long-lasting performance.
3. Awọn pato
| Sipesifikesonu | Iye |
|---|---|
| Ṣiṣẹ Voltage | 5V, 12V, 24V (Optional) |
| O pọju fifuye | AC 250V/10A; DC 30V/10A |
| Awọn ikanni | 2 |
| Ọja Mefa | 50 x 41 x 18.5 mm (2 x 1.6 x 0.7 inches) |
| Imọlẹ Atọka Agbara | Alawọ ewe |
| Relay Status Light | Pupa |
| Awọ Board | Pupa |
| Ohun elo olubasọrọ | Aluminiomu |
| Ti won won Lọwọlọwọ | 10 Ampere |
| Iṣagbesori Iru | PCB òke |
| Asopọmọra Iru | Dabaru ebute |
| Ipo Iṣiṣẹ | Laifọwọyi |
| Coil Voltage | 24 Volt (DC) - Note: Product is available in 5V, 12V, 24V versions. This specific model is 12V. |
| Kere Yipada Voltage | 5 folti |
Akojọ akopọ: 1 * Keenso 2-Channel Relay Module

Image 3.1: Keenso 2-Channel Relay Module with key dimensions.
4. Idanimọ paati
4.1. Relay Output Terminals

Aworan 4.1: alaye view of relay output terminals.
- NO1: Normally Open interface for Channel 1 relay. The relay is open before activation and short-circuited with COM1 after activation.
- COM1: Common interface for Channel 1 relay.
- NC1: Normally Closed interface for Channel 1 relay. It is short-circuited with COM1 before relay activation and open after activation.
- NO2: Normally Open interface for Channel 2 relay. The relay is open before activation and short-circuited with COM2 after activation.
- COM2: Common interface for Channel 2 relay.
- NC2: Normally Closed interface for Channel 2 relay. It is short-circuited with COM2 before relay activation and open after activation.
4.2. Power and Control Input Terminals

Aworan 4.2: alaye view of power and control input terminals.
- S1: Jumper for high/low-level trigger selection for Channel 1 relay.
- S2: Jumper for high/low-level trigger selection for Channel 2 relay.
- DC+: Connect to the positive pole of the power supply.
- DC-: Connect to the negative pole of the power supply.
- IN1: Signal trigger terminal for Channel 1. Can be set for high or low-level control for relay activation.
- IN2: Signal trigger terminal for Channel 2. Can be set for high or low-level control for relay activation.
5. Eto ati Wiring
Before connecting the module, ensure all power sources are disconnected to prevent electrical shock or damage to components.
5.1. Asopọ Ipese Agbara
- Sopọ awọn DC+ terminal to the positive (+) output of your power supply (e.g., 12V DC for this model).
- Sopọ awọn DC- terminal to the negative (-) output (ground) of your power supply.
- The green power indicator LED will illuminate when power is correctly supplied.
5.2. Load Connection
Each relay channel has three terminals: Normally Open (NO), Common (COM), and Normally Closed (NC). Choose the appropriate connection based on your application requirements.
- Normally Open (NO) Configuration: For a device that should be OFF when the relay is inactive and ON when the relay is activated, connect one side of your load to the RARA terminal and the other side to your power source. Connect the COM terminal to the other side of your power source.
- Normally Closed (NC) Configuration: For a device that should be ON when the relay is inactive and OFF when the relay is activated, connect one side of your load to the NC terminal and the other side to your power source. Connect the COM terminal to the other side of your power source.
5.3. Iṣakoso ifihan agbara Asopọ
- Connect your microcontroller's output pin to the IN1 terminal for Channel 1 or IN2 for Channel 2.
- Ensure the microcontroller's ground is connected to the relay module's DC- terminal for common ground reference.
6. Awọn ilana Iṣiṣẹ
6.1. Trigger Level Selection (S1, S2 Jumpers)
The module supports both high-level and low-level trigger modes, selected via the S1 and S2 jumpers for each channel.
- High-Level Trigger: When the jumper is set to 'High' (usually by connecting the jumper to the 'H' pin), the relay will activate when a high voltage signal (e.g., 3.3V or 5V, depending on your microcontroller's logic level) is applied to the IN terminal.
- Low-Level Trigger: When the jumper is set to 'Low' (usually by connecting the jumper to the 'L' pin), the relay will activate when a low voltage signal (e.g., 0V or ground) is applied to the IN terminal.
Pataki: Always ensure the trigger level selected by the jumper matches the output logic of your controlling device (microcontroller).
6.2. Relay Activation
- Once power and control signals are connected, apply the appropriate trigger signal (high or low, as configured) to the IN1 or IN2 terminal.
- The red relay status LED for the corresponding channel will illuminate when the relay is activated.
- You should hear a distinct click sound as the relay switches state.

Aworan 6.1: Example of a relay module used in an industrial control environment.
7. Itọju
- Jeki mimọ: Regularly inspect the module for dust or debris. Use a soft, dry brush or compressed air to clean.
- Awọn ipo Ayika: Operate the module within its specified temperature and humidity ranges. Avoid exposure to moisture, extreme temperatures, or corrosive environments.
- Iduroṣinṣin asopọ: Periodically check all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to intermittent operation or damage.
- Iduroṣinṣin Ipese Agbara: Ensure a stable and clean power supply. Voltage fluctuations can affect performance and lifespan.
8. Laasigbotitusita
- Relay Ko Ṣiṣẹ:
- Check power supply: Ensure the correct voltage (5V, 12V, or 24V, matching your module) is applied to DC+ and DC-.
- Verify trigger level: Confirm the S1/S2 jumper setting (high or low) matches the signal from your microcontroller.
- Check control signal: Use a multimeter to verify that the IN1/IN2 pins are receiving the expected trigger signal.
- Common ground: Ensure the ground of your control device is connected to the DC- terminal of the relay module.
- Power LED Not On:
- Check power connections: Ensure DC+ and DC- are correctly wired and receiving power.
- Verify power supply: Test your power supply to ensure it is providing the correct voltage.
- Relay Clicking Continuously/Erratic Behavior:
- Signal noise: Ensure your control signal is clean and free from electrical noise. Add a capacitor across the power lines if necessary.
- Incorrect trigger level: Double-check the S1/S2 jumper setting.
- Load Not Switching:
- Check load wiring: Ensure the load is correctly connected to the NO/COM or NC/COM terminals.
- Verify relay activation: Confirm the red status LED illuminates and you hear the click when the relay is triggered.
- Load compatibility: Ensure the load's voltage and current do not exceed the relay's maximum ratings (AC 250V/10A; DC 30V/10A).
9. Alaye Aabo
- Ewu Itanna: This module deals with electrical currents. Always disconnect power before making or changing any connections.
- Voltage ibamu: Rii daju pe iṣẹ voltage of the module (5V, 12V, or 24V) matches your power supply. Using an incorrect voltage le ba module.
- Awọn ifilelẹ fifuye: Maṣe kọja iwọn lọwọlọwọ ati voltage ratings of the relays (AC 250V/10A, DC 30V/10A). Overloading can cause damage, overheating, or fire.
- Proper Insulation: Rii daju pe gbogbo iwọn-gigatage connections are properly insulated to prevent short circuits and electrical shock.
- Fifi sori Ọjọgbọn: If you are unfamiliar with electrical wiring, seek assistance from a qualified electrician or electronics professional.
- Jeki kuro lati omi: Do not expose the module to water or high humidity.
10. Awọn ohun elo ọja
The Keenso 2-Channel Relay Module is versatile and can be used in various applications, including:
- Awọn ọna ṣiṣe adaṣe ile
- Industrial control systems
- DIY electronics projects
- Robotik
- Awọn ohun elo adaṣe
- Iṣakoso ina

Aworan 10.1: Examples of product applications in industrial and electronic settings.
11. Atilẹyin ọja ati Support
Keenso products are manufactured to high-quality standards. For warranty information or technical support, please refer to the seller's policy on the purchase platform or contact Keenso customer service directly through their official channels. Please have your product model number (B07PY7LF9Z) and purchase details ready when seeking support.