ZL-7918A Multifunction Automatic Temperature Humidity Controller

Afowoyi Itọsọna olumulo

1. Ifihan

The LILYTECH ZL-7918A is an advanced intelligent temperature and humidity controller designed for precise environmental management. It offers stable and reliable performance, making it ideal for applications such as incubators, climate chambers, and warehouses. This manual provides comprehensive instructions for the installation, operation, and maintenance of your ZL-7918A controller.

LILYTECH ZL-7918A controller with temperature and humidity sensors

Figure 1: LILYTECH ZL-7918A controller with connected temperature and humidity sensors, showing the main unit and external probes.

2. Key Awọn ẹya ara ẹrọ

The ZL-7918A controller is equipped with a range of features to ensure optimal environmental control:

  • Iṣakoso iwọn otutu: Precise management of heating elements.
  • Iṣakoso ọriniinitutu: Accurate regulation of humidity levels.
  • Iṣakoso ina: Manages illumination cycles.
  • Alapapo Iranlọwọ: Supports an additional heating output.
  • Egg Turning Control: Configurable periods and durations for automatic egg turning (left and right).
  • Timing Ventilation Control: Schedules ventilation cycles.
  • Iṣakoso Itaniji: Alerts for deviations from set parameters.
  • Iwọn otutu ati Iwọntunwọnsi ọriniinitutu: Allows for sensor calibration to maintain accuracy.
  • Hatching Day Display: Tracks and displays the number of hatching days (up to 99 days).

3. Eto ati fifi sori

3.1 Device Mefa ati fifi sori

The ZL-7918A controller has a device size of 160x80x95 mm. The recommended installation drilling size for mounting is 151.5x76.5 mm.

3.2 Awọn itọnisọna Wiring

Proper wiring is crucial for the safe and correct operation of the controller. Refer to the wiring diagram below for connections. Ensure all connections are secure and follow local electrical codes.

Pada view of ZL-7918A controller showing wiring terminals

olusin 2: Ẹyìn view of the ZL-7918A controller, displaying the terminal block for electrical connections.

Wiring diagram for ZL-7918A controller

Figure 3: Detailed wiring diagram for the ZL-7918A controller, illustrating connections for power supply, sensors, and output loads.

Ibi ti ina elekitiriki ti nwa: Connect AC100~240V 50/60Hz to terminals L and N (13 and 14).

Awọn sensọ:

  • Sensọ ọriniinitutu: Connect the Red, Yellow, Black, and Orange wires to terminals 1, 2, 3, and 4 respectively.
  • Sensọ iwọn otutu: Connect to terminals 5 and 6.
ZL-SHr05A Humidity Sensor

Figure 4: ZL-SHr05A Humidity Sensor, showing its compact design and connection points. This sensor is designed for accurate humidity measurement within a range of 0-80% RH.

Iṣakoso Ijade: The controller provides 7 output controls. Ensure the load for heaters does not exceed 1500W, illumination does not exceed 100W, and humidity, fan, and egg turning outputs do not exceed 1A/250Vac.

  • Àìpẹ: Terminals 15 (COM) and 16.
  • Egg Turning Left: Terminals 15 (COM) and 17.
  • Egg Turning Right: Terminals 15 (COM) and 18.
  • Ọriniinitutu: Terminals 15 (COM) and 19.
  • Illumination (Lamp): Terminals 15 (COM) and 20.
  • Auxiliary Heater (HEAT2): Terminals 21 and 22.
  • Main Heater (HEAT1): Terminals 23 and 24.

4. Isẹ

4.1 Ifihan Loriview

Iwaju view of ZL-7918A controller display

olusin 5: Iwaju view of the ZL-7918A controller, highlighting the digital display and control buttons for setting parameters.

The controller features a clear digital display showing current temperature (PV TEMP), set temperature (SV TEMP), current humidity (PV WET%), and set humidity (SV WET%). Indicator lights show the status of various outputs (FAN, HEAT1, HEAT2, UP, DOWN, WET, ALARM, L/R for egg turning).

4.2 Eto paramita

Use the "Set" button to enter the parameter setting mode and the arrow keys (Up/Down) to navigate and adjust values. The "Enter" button confirms selections.

  • Ibiti Eto iwọn otutu: 1 ~ 65℃
  • Ibiti Eto Ọriniinitutu: 10 ~ 80% RH
  • Egg-Turning Control:
    • Period: 1~999 minutes
    • Turning Time: 0~999 seconds
    • Turning Times: 0~999 times
  • Iṣakoso Afẹfẹ:
    • Period: 1~999 minutes
    • Ventilating Time: 0~999 seconds
  • Iṣakoso itanna:
    • Period: 1~999 minutes
    • Illuminating Time: 0~999 seconds

Refer to the detailed programming guide (not included in this general manual) for specific parameter codes and advanced settings.

5. Itọju

To ensure the longevity and accuracy of your ZL-7918A controller, follow these maintenance guidelines:

  • Ninu: Regularly wipe the controller's surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Itọju Sensọ: Keep the temperature and humidity sensors clean and free from dust or debris. Avoid exposing sensors to extreme physical shock or moisture beyond their operating limits.
  • Awọn isopọ: Lokọọkan ṣayẹwo gbogbo awọn asopọ onirin lati rii daju pe wọn wa ni aabo ati ominira lati ipata.
  • Iṣatunṣe: If accuracy issues are suspected, perform temperature and humidity calibration as per the advanced settings guide.

6. Laasigbotitusita

This section addresses common issues you might encounter with your ZL-7918A controller. For problems not listed here, please contact customer support.

IsoroOwun to le FaOjutu
Adarí ko ni agbara lori.Kò sí ìpèsè agbára; àwọn wáyà tí kò tọ́.Check power source (AC100~240V). Verify L and N wiring connections.
Awọn kika iwọn otutu / ọriniinitutu ti ko pe.Dirty or faulty sensor; need for calibration.Clean sensors. Perform temperature and humidity calibration. Replace sensor if faulty.
Output (e.g., heater, fan) not activating.Incorrect settings; faulty wiring; overloaded output.Check set parameters. Verify output wiring. Ensure load does not exceed specified limits (e.g., heaters ≤ 1500W).
Alarm constantly active.Parameters outside set limits; alarm threshold too narrow.Adjust set temperature/humidity or alarm thresholds. Ensure environmental conditions are within desired range.

7. Imọ ni pato

ParamitaIye
Ibi ti ina elekitiriki ti nwaAC100 ~ 240V 50/60Hz
Sensọ iwọn otutu1 (L=2M)
Ọriniinitutu Sensọ1 (L=2M)
Ọriniinitutu Eto Ibiti10 ~ 80% RH
Iwọn Eto Eto iwọn otutu1 ~ 65℃
Ọriniinitutu Ifihan Ibiti0 ~ 99% RH
Iwọn Ifihan Iwọn otutu-20 ~ 80 ℃
Humidity Measuring Accuracy±3% (under temperature 20~60℃)
Yiye Iwọn otutu± 1%
Iṣakoso Iṣakoso7 outputs (heater, aux-heater, fan, egg left-turning, egg right-turning, humidity, illumination)
Heater Output Load≤ 1500W
Illumination Output Load≤ 100W
Humidity, Fan, Egg Turning Output Load≤ 1A/250Vac
Hatching Day RecordMax 99 ọjọ
Ayika isẹ-10~45℃, <90%RH without dew
Iwọn Ẹrọ160x80x95 mm
Installation Drilling Size151.5x76.5 mm
Ohun eloṢiṣu
Ifihan IruLCD tabi LED

8. atilẹyin ọja Information

LILYTECH products are manufactured to high quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact LILYTECH customer support directly. Keep your purchase receipt as proof of purchase for any warranty claims.

9. Onibara Support

If you require further assistance or have questions regarding your ZL-7918A controller, please contact LILYTECH customer support. Contact details can typically be found on the product packaging or the official LILYTECH webojula.

For technical inquiries, please have your product model (ZL-7918A) and a detailed description of the issue ready.

© 2024 LILYTECH. All rights reserved.