Jectse Jectseh4tnewb30y-03
Jectse Timer Soft Starter Instruction Manual
Model: Jectseh4tnewb30y-03
1. Ọja Ipariview
The Jectse Timer Soft Starter is a versatile delay relay motor starter designed for efficient motor start control. It features adjustable delay ranges and wide working voltage compatibility, making it suitable for various industrial and scientific applications.

olusin 1: Iwaju view of the Jectse Timer Soft Starter, showing the control knobs and indicator lights.
2. Key Awọn ẹya ara ẹrọ
- Adjustable Start Delay (T1): Range from 0.1 seconds to 10 minutes, set via knob.
- Adjustable Conversion Time (T2): Range from 0.1 seconds to 1 second, set via knob.
- Wide Ṣiṣẹ Voltage: Supports AC/DC 12V to 240V.
- Awọn itọkasi LED: Clearly shows the working status of the relay.
- Apẹrẹ Iwapọ: Super small size, only 18mm wide, designed for 35mm rail mounting.

Figure 2: The soft starter unit highlighting its compact size and adjustable settings.
3. Alaye Aabo
Please read and understand all safety instructions before installing or operating this device. Failure to follow these instructions may result in electrical shock, fire, or serious injury.
- Ensure power is disconnected before any installation or wiring.
- Fifi sori yẹ ki o ṣee ṣe nipasẹ oṣiṣẹ ti o peye nikan.
- Daju pe voltage and current ratings before connecting to a power source.
- Ma ṣe fi ẹrọ naa han si ọrinrin tabi iwọn otutu to gaju.
- Rii daju pe ilẹ ti o tọ ni ibi ti o yẹ.
4. Package Awọn akoonu
Apo naa pẹlu:
- 1 x Jectse Timer Soft Starter
5. Eto ati fifi sori
The Jectse Timer Soft Starter is designed for 35mm DIN rail mounting. Follow these steps for proper installation:
- Ensure all power to the circuit is turned off at the main breaker.
- Mount the soft starter securely onto a standard 35mm DIN rail. The red clips on the side facilitate easy mounting and removal.
- Connect the power supply to terminals A1 and A2. The device supports AC/DC 12-240V.
- Connect the motor control wiring to the output terminals (15, 16, 18, 25, 26, 28) as per your application's wiring diagram. Refer to the diagram on the side of the unit for specific connections.
- Ensure all wiring connections are secure and meet the specified wiring capacity (1x2.5mm² or 2x 1.5mm²).
- Ṣayẹwo gbogbo awọn asopọ lẹẹmeji ṣaaju mimu-pada sipo agbara.

olusin 3: Isunmọ view of the wiring terminals and the integrated wiring diagram on the unit.

olusin 4: Apa view illustrating the red clips for DIN rail mounting.
6. Awọn ilana Iṣiṣẹ
Once installed and powered, the Timer Soft Starter operates based on its configured delay settings.
- Setting Start Delay (T1): Use the knob labeled 'T1' to adjust the initial start delay from 0.1 seconds to 10 minutes. This delay determines how long the soft starter waits before initiating the motor start sequence.
- Setting Conversion Time (T2): Use the knob labeled 'T2' to set the conversion time from 0.1 seconds to 1 second. This time is crucial for the smooth transition during the motor's soft start phase.
- Awọn itọkasi LED:
- A green LED indicates the power status (Un).
- A red LED indicates the relay's working status (R).
Fidio 1: Ipariview of the Jectse Timer Soft Starter, demonstrating its features and appearance.
7. Itọju
The Jectse Timer Soft Starter is designed for long-term reliability with minimal maintenance. However, regular checks can ensure optimal performance:
- Ṣe àyẹ̀wò àwọn ìsopọ̀ wáyà lẹ́ẹ̀kọ̀ọ̀kan fún wíwú àti àmì wíwú tàbí ìbàjẹ́.
- Keep the unit clean and free from dust and debris. Use a dry, soft cloth for cleaning.
- Rii daju pe agbegbe iṣẹ wa laarin iwọn otutu ti a sọ ati awọn sakani ọriniinitutu.
- Do not attempt to open or repair the unit yourself. Refer to qualified service personnel.
8. Laasigbotitusita
If you encounter issues with your Timer Soft Starter, consider the following common problems and solutions:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Unit not powering on (Green LED off) | No power supply; Incorrect wiring; Faulty unit. | Check power source; Verify A1/A2 wiring; Contact support if power is present and wired correctly. |
| Motor not starting after delay | Incorrect output wiring; Relay not activating; Motor issue. | Check output terminals (15, 16, 18, 25, 26, 28) connections; Observe red LED for relay status; Test motor independently. |
| Delay times are inaccurate | Knob settings incorrect; Environmental factors. | Re-adjust T1 and T2 knobs carefully; Ensure stable operating environment. |
If the problem persists after attempting these solutions, please contact Jectse customer support.
9. Awọn pato
| Paramita | Iye |
|---|---|
| Iru | AC/DC 12V~240V |
| Rated Control Power Supply Voltage | AC/DC 12-240V (50/60Hz) |
| Agbara agbara | AC 0.7-3VA / DC 0.5-1.7W |
| Starting Delay (T1) | 0.1s - 10min |
| Conversion Delay (T2) | 0.1-orundun-1s |
| Eto Yiye | 5% |
| Tun Yiye Tun | 0.2% |
| Abajade | Two sets of conversion contacts 16A/AC250VAC |
| Minimum Switching Power | 500mW |
| Igbesi aye ẹrọ | 1 x 10,000,000 cycles |
| Electrical Life (Load) | 1,000,000 iyipo |
| Tun Aago | 200ms ti o pọju |
| Ṣiṣẹ Ayika otutu | -20°C ~ 55°C |
| Ibi ipamọ ati Gbigbe Iwọn otutu | -35°C ~ 75°C |
| Fifi sori ẹrọ | 35mm iṣinipopada iṣagbesori |
| Ipele Idaabobo | IP20 |
| Fifi sori Giga | 2000 mita |
| Idoti Ipele | 2 |
| Agbara onirin | 1x2.5mm² or 2x 1.5mm² |
| Awọn iwọn | 90 x 18 x 64mm (3.5 x 0.7 x 2.5in) |
| Ni ibamu si Standard | GB14048.5.IEC/EN 60255-1 |
| Iwọn | Isunmọ 96g (3.4oz) |
10. Atilẹyin ọja ati Support
For warranty information or technical support, please contact Jectse customer service. Keep your purchase receipt for any warranty claims.
Olupese: Jectse
Nọmba awoṣe: Jectseh4tnewb30y-03
Ọjọ Akọkọ Wa: Oṣu Karun ọjọ 4, Ọdun 2019
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.