This manual provides essential information for the safe and efficient operation of your WilTec 19L Domestic Autoclave Pump with Pressure Switch, Model 61544. Please read these instructions carefully before installation, operation, or maintenance. Keep this manual for future reference.

This comprehensive system, consisting of a diaphragm tank and a powerful pressure switch pump, is designed for supplying clear water to both your home and garden. It is ideal for domestic water supply using rainwater, wastewater, or groundwater, reducing reliance on tap water for showering, laundry, and toilet use. In the garden, it supports automatic irrigation systems. The system can also be integrated into existing water networks to boost pressure.

It features a 1200W motor, a delivery head of 30m at 3 bar operating pressure, and a maximum pump pressure of 4.8 bar, delivering up to 3400 liters of clear water per hour. The 19-liter pressure tank is made of shock-resistant iron for stability and durability. A convenient handle facilitates easy transport, making it suitable for mobile use. An integrated manometer allows precise monitoring of operating pressure. The pressure switch activates the pump when water pressure drops due to water draw-off and automatically deactivates it once the tank is refilled. Maximum cut-in pressure is 1.5 bar, and maximum cut-out pressure is 3 bar. A larger tank capacity results in less frequent pump activation, leading to reduced energy consumption and electricity costs.

WilTec 19L Domestic Autoclave Pump, main view

Nọmba 1.1: Akọkọ view of the WilTec 19L Domestic Autoclave Pump. This image shows the pump unit mounted on top of the blue 19-liter pressure tank, with the electrical cable and pressure switch visible.

2. Awọn ilana aabo

IKILO: Failure to follow these safety instructions can result in electric shock, fire, serious injury, or death.

  • Always disconnect the pump from the power supply before performing any installation, maintenance, or cleaning tasks.
  • Ensure the electrical supply matches the specifications on the pump's rating plate.
  • The pump must be connected to a properly grounded outlet with a residual current device (RCD) for personal protection.
  • Do not operate the pump with damaged cables or plugs. Have them replaced by a qualified electrician.
  • Dáàbò bo ẹ̀rọ fifa omi náà kúrò lọ́wọ́ òtútù. Fa omi náà kúrò pátápátá tí ó bá wà nínú ewu òtútù.
  • This pump is designed for pumping clear water only. Do not use it for flammable, corrosive, explosive, or abrasive liquids.
  • Never run the pump dry. Ensure the pump is always primed with water before starting.
  • Pa awọn ọmọde ati awọn eniyan ti ko ni aṣẹ mọ kuro ni fifa ẹrọ ti n ṣiṣẹ.
  • Ensure adequate ventilation around the pump during operation.
  • Do not lift or carry the pump by its electrical cable.

3. Eto ati fifi sori

3.1 Unpacking ati ayewo

  • Fi ìṣọ́ra yọ fifa omi náà kúrò nínú àpò rẹ̀.
  • Inspect the pump for any signs of damage that may have occurred during transit. Do not operate a damaged pump.
  • Rii daju pe gbogbo awọn eroja wa.

3.2 Ibi

  • Place the pump on a firm, level, and stable surface to prevent vibration and movement.
  • Position the pump in a dry, well-ventilated area, protected from direct sunlight, rain, and frost.
  • Ensure sufficient space around the pump for ventilation and maintenance access.

3.3 Itanna Asopọ

  • Connect the pump to a standard 230V, 50Hz electrical outlet.
  • Always use a grounded outlet protected by a residual current device (RCD) with a tripping current of no more than 30mA.
  • Ensure the power cable is not stretched, pinched, or exposed to sharp edges.

3.4 Suction Line Connection

  • Connect a non-collapsible, airtight suction hose to the pump's suction inlet. Use thread sealant tape for a secure, leak-free connection.
  • The suction hose should be as short and straight as possible to minimize friction loss.
  • Install a foot valve with a filter at the end of the suction hose in the water source to prevent debris from entering the pump and to maintain prime.
  • Ensure the foot valve is always submerged in water.

3.5 Pressure Line Connection

  • Connect the pressure hose to the pump's pressure outlet.
  • Rii daju pe gbogbo awọn asopọ wa ni wiwọ ati laisi jo.

3.6 Priming fifa soke

  • Before initial startup, the pump housing must be completely filled with water through the priming port (usually located on top of the pump).
  • Open any valves in the pressure line to allow air to escape during priming.
  • Once filled, close the priming port securely.
WilTec 19L Domestic Autoclave Pump, side view

Nọmba 3.1: Apa view of the pump, illustrating the general layout of the motor, pump head, and pressure tank. This view helps in identifying the suction and pressure ports for hose connections.

4. Awọn ilana Iṣiṣẹ

4.1 Ibẹrẹ Ibẹrẹ

  1. Ensure the pump is properly installed and primed as described in Section 3.
  2. Plug the pump into the electrical outlet. The pump will start automatically if the pressure in the tank is below the cut-in pressure.
  3. Monitor the manometer to observe the pressure build-up.
  4. Allow the pump to run until it reaches the cut-out pressure and switches off automatically.

4.2 Iṣiṣẹ Aifọwọyi

  • The integrated pressure switch controls the pump's operation. When water is drawn from the system (e.g., opening a tap), the pressure drops.
  • Once the pressure falls below the set cut-in pressure (approx. 1.5 bar), the pump automatically starts to replenish the tank and supply water.
  • When water draw-off stops and the system pressure reaches the set cut-out pressure (approx. 3 bar), the pump automatically switches off.
  • This automatic start/stop function ensures efficient water supply and reduces energy consumption.

4.3 Abojuto

  • Regularly check the manometer to ensure the system is operating within expected pressure ranges.
  • Fetí sílẹ̀ fún àwọn ìró tàbí ìgbọ̀nsẹ̀ tí kò wọ́pọ̀, èyí tí ó lè fi ìṣòro hàn.

4.4 Tiipa

  • For temporary shutdown, simply unplug the pump from the power outlet.
  • For extended periods of non-use or winterization, follow the maintenance instructions in Section 5.

5. Itọju

Itọju deedee n ṣe idaniloju pe fifa rẹ yoo pẹ to ati pe yoo ṣiṣẹ daradara.

5.1 Gbogbogbo sọwedowo

  • Periodically check all connections for leaks. Tighten as necessary.
  • Ṣayẹwo okun agbara ati pulọọgi fun eyikeyi ibajẹ.
  • Ensure the pump's ventilation openings are clear of debris.

5.2 Suction Filter Cleaning

  • If a foot valve with a filter is used, regularly check and clean the filter to prevent clogging and maintain efficient suction.
  • A clogged filter can lead to reduced pump performance or dry running.

5.3 Diaphragm Tank Pressure Check

  • The air pressure in the diaphragm tank should be checked periodically (e.g., every 6-12 months) when the pump is depressurized and empty of water.
  • The pre-charge pressure should typically be around 1.5 bar (check product specifications for exact value). Adjust with a standard air pump if necessary.
  • Incorrect tank pressure can lead to frequent pump cycling.

5.4 Igba otutu

  • If the pump is stored or used in an area where temperatures may drop below freezing, it must be completely drained to prevent damage from ice expansion.
  • Ge asopọ agbara.
  • Open the drain plug (if available) and disconnect the suction and pressure lines to allow all water to escape.
  • Tọju fifa soke ni ibi gbigbẹ, ti ko ni otutu.

6. Laasigbotitusita

Before contacting support, please refer to the following troubleshooting guide:

IsoroOwun to le FaOjutu
Pump ko bẹrẹKo si ipese agbara
Aṣiṣe iyipada titẹ
Apọju mọto
Check power connection, fuse, RCD
Check pressure switch settings
Allow motor to cool, check for blockages
Pump runs but no water is deliveredFifa ko primed
Afẹfẹ ni laini afamora
Suction line leak
Àtọwọdá ẹsẹ dí
Giga afamora ga ju
Prime the pump completely
Check suction line for leaks, tighten connections
Clean foot valve filter
Reduce suction height or use a pre-filter
Irẹ titẹ kekere tabi sisan sisan ti o dinkuPartial blockage in suction/pressure line
Afẹfẹ ninu eto
Wọ awọn paati fifa
Incorrect tank pressure
Check and clear lines
Re-prime pump, check for leaks
Olubasọrọ iṣẹ
Check and adjust tank pre-charge pressure
Pump cycles frequentlyLeak in pressure system
Insufficient air in pressure tank
Small water draw-off
Check all connections and fixtures for leaks
Check and adjust tank pre-charge pressure
This is normal for very small water draws
Ariwo / gbigbọn daniAfẹfẹ ni fifa
Foreign object in pump
Iṣagbesori alaimuṣinṣin
Re-prime pump
Disconnect power and inspect impeller (if accessible)
Ensure pump is securely mounted

If the problem persists after attempting these solutions, please contact WilTec customer support.

7. Imọ ni pato

WilTec 19L Domestic Autoclave Pump with dimensions

Nọmba 7.1: Dimensions of the WilTec 19L Domestic Autoclave Pump. This image provides key measurements for installation planning, showing length, width, and height in millimeters.

Ẹya ara ẹrọSipesifikesonu
Nọmba awoṣe61544
BrandWilTec
Agbara1200 W
Oṣuwọn Sisan ti o pọju3400 liters fun wakati kan
O pọju Gbe Giga30 Mita
O pọju Pump Titẹ4.8 igi
Cut-in Pressure (approx.)1.5 igi
Cut-out Pressure (approx.)3 igi
Diaphragm Tank Capacity19 liters
Awọn iwọn Ọja (L x W x H)45.5 x 26.5 x 50 cm
Iwọn Nkan11.06 kilo
Ohun eloIrin
Àwọ̀Buluu
Orisun agbaraCable ina
Performance curve for the WilTec pump

Nọmba 7.2: Performance curve (H[m] vs Q[l/h]) for the pump, illustrating the relationship between delivery head and flow rate. This graph helps understand the pump's capabilities under different operating conditions.

8. Atilẹyin ọja ati Support

For warranty information, please refer to the terms and conditions provided at the point of purchase or contact your retailer. In case of technical issues or questions not covered in this manual, please contact WilTec customer support or the seller for assistance.

Jọwọ ni nọmba awoṣe rẹ (61544) ati rira awọn alaye ṣetan nigbati o kan si atilẹyin.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.