1. Ifihan
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your CombiSteel 500L 3-Door Refrigerated Back Bar Cooler, Model 7489.5275. Please read these instructions thoroughly before installation and use to ensure proper function and longevity of the appliance. Retain this manual for future reference.
2. Awọn ilana aabo
Observe the following safety precautions to prevent injury and damage to the appliance:
- Rii daju pe ohun elo naa ti sopọ si iṣan agbara ti ilẹ pẹlu fol to petage (230V, 50Hz).
- Maṣe ṣiṣẹ ohun elo pẹlu okun agbara ti bajẹ tabi pulọọgi.
- Jeki awọn šiši fentilesonu kuro ninu awọn idena.
- Ma ṣe fi awọn nkan ibẹjadi pamọ gẹgẹbi awọn agolo aerosol pẹlu itọka ina ninu ohun elo yii.
- Àwọn òṣìṣẹ́ tó ní ìmọ̀ nìkan ló yẹ kí wọ́n ṣe àtúnṣe tàbí ìtọ́jú.
- Ge asopọ agbara agbara ṣaaju ṣiṣe mimọ tabi ṣiṣe.
- This appliance uses R290 refrigerant. Handle with care and ensure proper ventilation during servicing.
3. Eto ati fifi sori
3.1 Ṣiṣii silẹ
Carefully remove all packaging materials. Inspect the appliance for any shipping damage. Report any damage immediately to the carrier and supplier.
3.2 Ibi
Position the cooler on a firm, level surface capable of supporting its weight (approximately 160 kg when empty, more when loaded). Ensure adequate air circulation around the unit, especially at the rear where the condenser is located. Maintain a minimum clearance of 10 cm (4 inches) from walls or other obstructions to allow for proper ventilation and heat dissipation. Avoid direct sunlight or proximity to heat sources.

Aworan 1: Iwaju view of the CombiSteel 500L 3-Door Refrigerated Back Bar Cooler. This image shows the overall appearance of the unit with its three black doors and control panel on the right side.

Image 2: Technical drawing illustrating the dimensions of the CombiSteel 500L 3-Door Refrigerated Back Bar Cooler. Key measurements include width (1940mm), depth (550mm), and height (950mm), along with internal shelf dimensions.
3.3 Itanna Asopọ
Connect the appliance to a dedicated 230V, 50Hz power supply. Ensure the circuit is protected by a suitable fuse or circuit breaker. Do not use extension cords or multi-plugs.
3.4 Ni ibẹrẹ Cleaning
Before first use, clean the interior and exterior of the cooler with a mild detergent and warm water. Rinse thoroughly and dry completely. Do not use abrasive cleaners or solvents.
3.5 Ibẹrẹ Ibẹrẹ
After placement and cleaning, allow the unit to stand for at least 2 hours before plugging it in. This allows the refrigerant to settle. Once plugged in, allow the cooler to run empty for several hours (e.g., 4-6 hours) to reach its operating temperature range of -2°C to +8°C before loading products.
4. Awọn ilana Iṣiṣẹ
4.1 otutu Iṣakoso
The cooler features an electronic temperature control system. The desired temperature can be set within the range of -2°C to +8°C. Refer to the control panel instructions for specific temperature adjustment procedures. The display shows the current internal temperature.
4.2 Loading Guidelines
Load products evenly on the six provided shelves. Do not overload the shelves or block the internal air circulation vents. Overloading can impair cooling efficiency. Ensure bottles or containers do not obstruct the door closure.
4.3 Ìyọ́kúrò Àìfọwọ́ṣe
This appliance is equipped with an automatic defrosting system. Frost buildup on the evaporator will be periodically melted and the water evaporated. Do not attempt to manually defrost with sharp objects.
5. Itọju
Regular maintenance ensures optimal performance and extends the lifespan of your cooler.
5.1 Ninu ilohunsoke
Clean the interior regularly with a mild, non-abrasive detergent and warm water. Remove shelves and clean them separately. Rinse and dry thoroughly before replacing. Avoid getting water into electrical components.
5.2 Ninu Ode
Wipe the exterior surfaces with a soft cloth and mild detergent. For stainless steel surfaces, use a specialized stainless steel cleaner. Do not use abrasive pads or cleaners that could scratch the finish.
5.3 Ìmọ́tótó Kondenser
The condenser coil, located at the rear or bottom of the unit, should be cleaned periodically (e.g., every 3-6 months) to maintain cooling efficiency. Disconnect power before cleaning. Use a soft brush or vacuum cleaner to remove dust and debris from the fins. A dirty condenser can lead to increased energy consumption and reduced cooling performance.
5.4 Awọn edidi ilekun
Inspect door seals regularly for damage or wear. Clean them with warm, soapy water. Ensure they form a tight seal when the doors are closed to prevent cold air loss.
6. Laasigbotitusita
Ṣaaju ki o to kan si iṣẹ, tunview Awọn iṣoro ti o wọpọ ati awọn solusan wọnyi:
- Ohun elo ko tutu:
- Ṣayẹwo boya okun agbara ti wa ni edidi ni aabo.
- Ṣe àyẹ̀wò ẹ̀rọ ìfọ́ tàbí fiusi.
- Ensure the temperature setting is correct.
- Check if the condenser coil is clean and not obstructed.
- Confirm doors are closing properly and seals are intact.
- Ariwo nla:
- Rii daju pe ẹyọ naa jẹ ipele ati iduroṣinṣin.
- Check for loose components or items inside the cooler.
- A slight hum from the compressor is normal.
- Omi lori ilẹ:
- Check if the drain pan is correctly positioned or if the drain line is blocked.
- Rii daju pe ẹrọ naa jẹ ipele.
- Awọn ilẹkun ko tii daradara:
- Ṣayẹwo fun awọn idena.
- Inspect door hinges and seals for damage.
Ti awọn iṣoro ba tẹsiwaju lẹhin igbiyanju awọn ojutu wọnyi, kan si onimọ-ẹrọ iṣẹ ti o peye.
7. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Brand | CombiSteel |
| Nọmba awoṣe | 7489.5275 |
| Type of Refrigeration | Agbara afẹfẹ |
| Capacity (Gross) | 500 liters |
| Nọmba ti ilẹkun | 3 |
| Defrost Eto | Laifọwọyi |
| Max ibaramu otutu | 32°C |
| Ọja Line | Laini Pro |
| Ìbú | 1940 mm |
| Ijinle | 550 mm |
| Giga | 950 mm |
| Ohun elo inu inu | Irin alagbara 430 |
| Àwọ̀ | Dudu |
| Iwon girosi | 160 kg |
| Voltage | 230 V |
| Igbohunsafẹfẹ | 50 Hz |
| Itanna Agbara | 0.46 kW |
| Firiji | R290 |
| Iwọn otutu | -2°C si +8°C |
| Number of Grids/Shelves | 6 |
8. Atilẹyin ọja ati Support
Information regarding warranty coverage and availability of spare parts is not provided in the product details. For warranty claims or technical support, please contact your retailer or the manufacturer directly, providing your model number (7489.5275) and purchase date.