Alerton 010338049213
Ìwé Àgbékalẹ̀ Olùlò Aleron VLD-362
Awoṣe: 010338049213
1. Ifihan
The Alerton VisualLogic Display (VLD) is a communicating sensor-controller combination featuring built-in temperature and humidity sensors. It is designed for common applications such as rooftop units, fan-coil units, and heat pumps. This device offers a cost-effective solution for in-room hotel requirements, providing an easy-to-use interface, a clear digital display, and the ability to switch between Celsius and Fahrenheit. The VLD-362W model includes an integrated wireless receiver for communication with various sensors, detecting occupancy and whether doors or windows are open or closed, and reporting this data to the front-end Building Automation System (BAS).
2. Ọja Ipariview

An image showing the Alerton VLD-362 Visual Logic Display Sensor-Controller. The device is white with a green digital display showing 'Inside 72', 'Set To 72', '12:54 pm', and '20% Humidity'. Buttons for 'FAN', 'SYSTEM', 'AUTO', 'SCHED', 'CLOCK', 'SCREEN', and 'MORE' are visible. The brand 'ALERTON' is printed at the bottom.
Awọn ẹya pataki:
- Communicating sensor-controller combination with built-in temperature and humidity sensor.
- Designed for common applications such as rooftop units, fan-coil units, and heat pumps.
- Cost-effective solution for in-room hotel requirements.
- Easy-to-use interface and clear digital display.
- Celsius/Fahrenheit change-over capability.
- Integrated wireless receiver (VLD-362W model) for communication with occupancy, door, and window sensors.
3. Awọn ilana iṣeto
3.1 Iṣagbesori
- Select a suitable indoor location away from direct sunlight, drafts, or heat sources that could affect temperature readings.
- Rí i dájú pé ojú ìfìkọ́lé náà jẹ́ pẹ̀lẹ́pẹ̀lẹ́ àti pé ó dúró ṣinṣin.
- Ṣí ẹ̀rọ náà dáadáa casing to access the mounting holes.
- So ẹrọ naa mọ ogiri nipa lilo awọn skru ati awọn ìdákọ̀ró ti o yẹ.
- Pa casing securely after mounting.
3.2 Onirin
- IKILO: Ensure all power to the HVAC system and the controller is disconnected before beginning wiring.
- Refer to the wiring diagram provided with your specific unit for terminal connections.
- Connect the power supply wires to the designated power terminals.
- Connect the communication wires (e.g., BACnet MS/TP) to the appropriate communication terminals, ensuring correct polarity.
- Connect the control wires to the HVAC equipment (e.g., fan, heating, cooling stages) as per the system design.
- Verify all connections are secure and correctly terminated.
3.3 Ibẹrẹ Agbara-soke
- Restore power to the HVAC system and the Alerton VLD-362.
- The display should illuminate and show initial boot-up information.
- Follow any on-screen prompts for initial configuration, such as date, time, and unit settings (Celsius/Fahrenheit).
4. Awọn ilana Iṣiṣẹ
4.1 Ifihan Lilọ kiri
The VLD-362 features a clear digital display with various buttons for navigation and control. The main screen typically shows current indoor temperature, setpoint, time, and humidity.
4.2 Eto otutu
- Lo awọn Up ati Isalẹ arrow buttons next to the 'Set To' display to adjust the desired temperature setpoint.
- Ifihan naa yoo fi ipo tuntun han bi o ṣe n ṣatunṣe rẹ.
4.3 System Ipo Aṣayan
Tẹ awọn ETO button to cycle through available system modes such as:
- gbigbona: Ó ń mú iṣẹ́ ìgbóná ṣiṣẹ́.
- Itura: Ó ń mú iṣẹ́ ìtútù ṣiṣẹ́.
- LATIO: Automatically switches between heating and cooling based on setpoints.
- PA: Turns off the HVAC system.
4.4 Àṣàyàn Ipò Àfẹ́fẹ́
Tẹ awọn FAN bọtini lati yipo nipasẹ awọn ipo iṣẹ afẹfẹ:
- LATIO: Fan nṣiṣẹ nikan nigbati alapapo tabi itutu agbaiye nṣiṣẹ.
- LATI: Fan nṣiṣẹ lemọlemọfún.
4.5 Scheduling (SCHED)
Tẹ awọn ṢẸJẸ button to access and modify the programmed schedule. Refer to the on-screen prompts for setting daily or weekly schedules for temperature and system modes.
4.6 Clock and Screen Settings
- Tẹ Aago to adjust the current time and date.
- Tẹ Iboju to adjust display brightness or contrast settings.
5. Itọju
5.1 Ninu ẹrọ naa
- Wipe the exterior of the VLD-362 with a soft, damp asọ.
- Má ṣe lo àwọn ohun ìfọṣọ, àwọn ohun olómi, tàbí àwọn ohun ìfọṣọ kẹ́míkà, nítorí pé wọ́n lè ba ìfihàn náà jẹ́ tàbí kí wọ́n ba ìfọṣọ náà jẹ́.asing.
- Ensure no liquid enters the device.
5.2 Sensor Calibration (Advanced)
The temperature and humidity sensors are factory calibrated. If you suspect inaccurate readings, consult a qualified HVAC technician or Alerton support for potential recalibration procedures. Do not attempt to recalibrate without proper tools and knowledge.
5.3 famuwia imudojuiwọn
Periodically check the Alerton official website or consult your system integrator for available firmware updates. Firmware updates can provide performance improvements and new features. Follow the provided instructions carefully when performing updates.
6. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ifihan ti ṣofo tabi ko dahun. | No power; loose wiring; internal fault. | Check power supply to the unit. Verify wiring connections. If problem persists, contact support. |
| Awọn kika iwọn otutu/ọriniinitutu ti ko tọ. | Sensor obstruction; improper mounting location; sensor fault. | Ensure no objects are blocking the sensor vents. Verify the device is mounted in an appropriate location. Contact support if readings remain inaccurate. |
| Ètò HVAC kò dáhùn sí olùdarí. | Incorrect wiring; communication issue; HVAC system fault. | Check all wiring connections between the controller and HVAC system. Verify communication settings. Ensure HVAC system is powered on and functional. |
| Cannot change settings or access menus. | Keypad lockout; system error. | Check if a keypad lockout feature is enabled (refer to advanced settings). Try power cycling the device. |
7. Awọn pato
| Iwa | Iye |
|---|---|
| Brand | Alerton |
| Olupese | Alerton |
| Nọmba awoṣe | 010338049213 |
| Iwọn Nkan | 401 g |
| Package Mefa | 19.3 x 13.9 x 5.3 cm |
| ASIN | B081ZLR83C |
| Ọjọ Akọkọ Wa | Oṣu Kẹta ọdun 10, Ọdun 2020 |
| Apapọ opoiye | 1.0 iṣiro |
8. Atilẹyin ọja ati Support
Alerton products are designed for reliability and performance. For specific warranty information regarding your VLD-362 Visual Logic Display Sensor-Controller, please refer to the warranty card included with your product or visit the official Alerton website. For technical support, troubleshooting assistance beyond this manual, or service inquiries, please contact Alerton customer support or your authorized Alerton dealer. Ensure you have your model number and purchase details ready when contacting support.
Alerton Official Webojula: www.alerton.com
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.