OWON HDS1021MN

OWON HDS1021MN Handheld Digital Storage Oscilloscope and Digital Multimeter User Manual

Model: HDS1021MN

1. Ifihan

The OWON HDS1021MN is a versatile handheld device combining the functionalities of a digital storage oscilloscope and a digital multimeter. It is designed for engineers, technicians, and hobbyists requiring portable and accurate measurement capabilities. This manual provides essential information for the safe and effective operation of your device.

Awọn ẹya pataki:

  • Awoṣe: HDS1021MN
  • Sample Rate (real time): 500MS/s
  • Bandiwidi: 20MHz
  • Horizontal Scale (s/div): 5ns/div to 100s/div, step by 1-2.5-5
  • Ikanni: Nikan
  • Waveform Record & Replay
  • FFT Functions
  • 3.7 inch color TFT display (640 × 480 pixels)

2. Alaye Aabo

Before using the OWON HDS1021MN, please read and understand all safety instructions. Failure to follow these instructions may result in electric shock, fire, or damage to the device or other equipment.

  • Aabo gbogbogbo: Always operate the device within its specified voltage and current limits. Do not use the device if it appears damaged or is not operating correctly.
  • Ibi ti ina elekitiriki ti nwa: Use only the specified power adapter and battery. Ensure the power source matches the device's requirements.
  • Probes and Leads: Use only probes and test leads rated for the voltage and current being measured. Inspect probes and leads for damage before each use.
  • Ayika: Ma ṣe ṣiṣẹ ẹrọ naa ni tutu tabi damp conditions, or in explosive atmospheres. Keep the device away from strong electromagnetic fields.
  • Ṣiṣẹ: Tọkasi gbogbo iṣẹ si awọn oṣiṣẹ iṣẹ ti o peye. Ma ṣe gbiyanju lati ṣii tabi tun ẹrọ naa funrararẹ.

3. Ọja irinše

The standard package for the OWON HDS1021MN typically includes the following items:

  • OWON HDS1021MN Handheld Digital Storage Oscilloscope and Digital Multimeter Unit
  • Oscilloscope Probe (1X/10X)
  • Awọn itọsọna Igbeyewo Multimeter
  • Adapter agbara
  • Okun USB
  • Afowoyi Olumulo (iwe-ipamọ yii)
  • Soft Carrying Case (may vary by region/retailer)
OWON HDS1021MN Handheld Digital Storage Oscilloscope and Digital Multimeter

Iwaju view of the OWON HDS1021MN, showing the display screen, control buttons, and input jacks.

4. Eto

4.1 Batiri sori ati gbigba agbara

  1. Wa ibi ipamọ batiri naa ni ẹhin ẹrọ naa.
  2. Insert the provided Li-ion battery (7.4V) into the compartment, ensuring correct polarity.
  3. Pa ideri batiri naa ni aabo.
  4. Connect the power adapter to the device's charging port and plug it into a suitable AC outlet (100V-240V AC, 50/60Hz). The battery indicator will show charging status.
  5. Allow the device to charge fully before initial use. A full charge provides approximately 6 hours of operation.

4.2 Àwọn Ìwádìí Tó Sopọ̀ àti Àwọn Ìtọ́sọ́nà Ìdánwò

  • Oscilloscope Probe: For oscilloscope functions, connect the BNC connector of the oscilloscope probe to the BNC input port on the device. Ensure the probe's attenuation setting (e.g., 1X or 10X) matches the setting on the oscilloscope menu.
  • Àwọn Ìdánwò Onímílítà Mọ́mbà: For multimeter functions, insert the red test lead into the VΩmA input jack and the black test lead into the COM input jack. For high current measurements (e.g., 20A), use the dedicated current input jack if available and switch the function accordingly.

5. Awọn ilana Iṣiṣẹ

5.1 Agbara Tan / Pa

Press and hold the power button until the display illuminates to turn on the device. To power off, press and hold the power button again until the display shuts down.

5.2 Oscilloscope isẹ

  1. Select Oscilloscope Mode: Use the function selection buttons to switch to oscilloscope mode.
  2. Ìwádìí Sopọ̀: Attach the oscilloscope probe to the circuit under test. Ensure the ground clip is connected to the circuit's ground.
  3. Adjust Vertical Scale (Volts/Div): Use the vertical control knob or buttons to adjust the voltage sensitivity per division, matching the amplitude ti awọn input ifihan agbara.
  4. Adjust Horizontal Scale (Time/Div): Use the horizontal control knob or buttons to adjust the time base per division, suitable for viewing the signal's frequency.
  5. Set Trigger: Use the trigger controls to stabilize the waveform. Common trigger types include Edge, Video, and Alternate. Adjust the trigger level to a point on the waveform to ensure a stable display.
  6. Acquisition Mode: Yan Sample, Peak Detect, or Average mode based on measurement needs.
  7. Waveform Record & Replay: Access the menu to enable waveform recording. Follow on-screen prompts to save and replay captured waveforms.
  8. Iṣẹ́ FFT: Activate the FFT (Fast Fourier Transform) function from the menu to analyze the frequency components of the signal.

5.3 Multimeter isẹ

  1. Select Multimeter Mode: Use the function selection buttons to switch to multimeter mode.
  2. Select Measurement Function: Rotate the rotary switch or press function buttons to select the desired measurement (e.g., VDC, VAC, Current DC, Current AC, Resistance, Diode, Continuity).
  3. So awọn itọsọna idanwo pọ: Connect the red and black test leads to the circuit or component being measured according to the selected function.
  4. Ka Iwọn: The measurement value will be displayed on the screen.
  5. Idanwo Diode: Connect leads across the diode. The forward voltage silẹ yoo han.
  6. Idanwo Ilọsiwaju: Connect leads across the circuit. An audible beep indicates continuity (<50Ω).

6. Itọju

6.1 Ninu

Lati nu ẹrọ naa, lo asọ asọ dampened with mild detergent and water. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from all power sources before cleaning.

6.2 batiri Itọju

  • Gba agbara batiri nigbagbogbo, paapaa ti ẹrọ naa ko ba si ni lilo nigbagbogbo, lati ṣetọju ilera batiri.
  • Yago fun gbigba agbara si batiri ni kikun nigbagbogbo.
  • Tí o bá ń tọ́jú ẹ̀rọ náà fún ìgbà pípẹ́, gba agbára bátìrì náà sí nǹkan bí 50% kí o sì tọ́jú rẹ̀ sí ibi tí ó tutù tí ó sì gbẹ.

6.3 Ibi ipamọ

Store the device in a dry, dust-free environment, away from direct sunlight and extreme temperatures. Use the provided carrying case to protect it from physical damage.

7. Laasigbotitusita

This section addresses common issues you might encounter with your OWON HDS1021MN.

IsoroOwun to le FaOjutu
Ẹrọ naa ko ṣiṣẹLow or dead battery; Power adapter not connected; Device faultCharge the battery; Connect power adapter; Contact support if issue persists
No waveform displayed (Oscilloscope)Probe not connected; Incorrect vertical/horizontal scale; Incorrect trigger settings; No input signalCheck probe connection; Adjust Volts/Div and Time/Div; Adjust trigger level/mode; Verify signal source
Incorrect multimeter readingIncorrect function selected; Test leads improperly connected; Damaged test leads; Out of range measurementSelect correct function; Ensure leads are in correct jacks; Replace damaged leads; Check measurement range
Ifihan ti wa ni baibai tabi flickerLow battery; Environmental factorsCharge battery; Operate in recommended temperature range

8. Awọn pato

Detailed technical specifications for the OWON HDS1021MN.

Àwọn Ìlànà Oscilloscope:

  • Bandiwidi: 20MHz
  • Sample Rate (real time): 500MS/s
  • Horizontal Scale (s/div): 5ns/div to 100s/div, step by 1-2.5-5
  • Rise Time (at input, typical): ≤ 17.5ns
  • Ifihan: 3.7 inch color TFT panel (640 × 480 pixels, 65535 colors)
  • Ikanni: Nikan
  • Imudaniloju igbewọle: 1MΩ ± 2%, in parallel with 20pF ± 5pF
  • Record Length: max 6K points on each channel
  • Interpolation: sin (x) / x
  • Probe Attenuation Factor: 1X, 10X, 100X, 1000X
  • Iṣajọpọ Iṣagbewọle: DC, AC, and GND
  • DC Accuracy (average): average >16 : ±(5% reading + 0.05div) for ΔV
  • Ifamọ inaro: 5mV/div to 5V/div (at input)
  • Vertical Resolution (A/D): 8 bit (awọn ikanni 2 ni igbakanna)
  • Iwọn titẹ sii Voltage: 400V (PK - PK) (DC + AC, PK - PK, 1MΩ input impedance, probe attenuation 10:1), CAT II
  • Iru okunfa: Edge, Video, Alternate
  • Ipo Nfa: Aifọwọyi, Deede, Nikan
  • Ipele okunfa: ±6 divisions from screen center
  • Acquisition Mode: Sample, Peak Detect, and Average
  • Ipeye DC Jèrè: ± 3%
  • Iwọn Aifọwọyi: Vpp, Vavg, Vrms, Freq, Period, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot, Pre-shoot, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay A→B, Delay A→B
  • Iṣiro Ìrísí Wíwọ́-ẹ̀rọ: +, -, ×, ÷, invert, FFT
  • Ibi ipamọ igbi igbi: 4 waveforms
  • Lissajous Figure: Bandwidth full bandwidth, Phase Difference ±3 degrees

Àwọn Ìlànà Onímìtìrà Púpọ̀:

  • Full Scale Reading: 3 ¾ digit (max 4000-count)
  • Diode: 0V-1.5V
  • Imudaniloju igbewọle: 10 MΩ
  • On / Off Test: <50Ω (± 30Ω) beeping
  • Voltage VDC: 400mV, 4V, 40V, 400V, 1000V : ±(1% ± 1 digit); max input : DC 1000V
  • Voltagati VAC: 4V, 40V, 400V : ±(1% ± 3 digits), 750V : ±(2% ± 3 digits); Frequency : 40Hz - 400Hz; max input : AC 750V (virtual value)
  • Current DC: 40mA, 400mA : ±(1.5% ± 1 digit), 20A : ±(3% ± 3 digits)
  • Current AC: 40mA : ±(1.5% ± 3 digits), 400mA : ±(2% ± 1 digit), 20A : ±(5% ± 3 digits)

Awọn Ni pato:

  • Ibaraẹnisọrọ Ibaraẹnisọrọ: USB
  • Ibi ti ina elekitiriki ti nwa: 100V-240V AC, 50/60Hz
  • Batiri Li-ion: 7.4V, 6 hours operation
  • Mefa (W × H × D): 180 × 115 × 40 (mm)
  • Àwọ̀: ọsan

9. Atilẹyin ọja ati Support

OWON products are manufactured to high quality standards. For warranty information, please refer to the warranty card included with your product or visit the official OWON website. For technical support, troubleshooting assistance beyond this manual, or service inquiries, please contact OWON customer support through their official channels.

Olupese: OWON

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.