MICRO-AIR EasyStart Breeze 399
MICRO-AIR EasyStart Breeze 399 User Manual
To ti ni ilọsiwaju Soft Starter fun RV Air Conditioners
1. Ifihan
The MICRO-AIR EasyStart Breeze 399 is an advanced soft starter designed to significantly reduce the startup current of your RV air conditioner or refrigeration compressor. This device enables the use of smaller generators or limited power sources to operate your RV's air conditioning system, enhancing comfort and efficiency.

Figure 1.1: The EasyStart Breeze 399 unit shown with its comprehensive installation kit, including wires, connectors, and mounting hardware.
2. Key Awọn ẹya ara ẹrọ
- Ibamu gbooro: Designed for RV air conditioners with capacities up to 13k–15k BTU. Supports RV AC soft start systems and works with 2200-watt generators. Capable of running two air conditioners with a total amperage of less than 30 amps on a 30-amp okun agbara.
- Quieter Start-ups: Reduces compressor startup noise for a more comfortable RV environment.
- Apẹrẹ Iwapọ: Features a small footprint for easier installation and efficient space utilization.
- Reduced Starting Current: Lowers the inrush current of your RV air conditioner or refrigeration compressor by up to 75%. Compatible with inverter generators.
- Easy Installation & Versatile Use: Includes detailed installation guides and video tutorials. Suitable for RV camper air conditioners and heat pumps, enhancing fault detection and protection.

Olusin 2.1: Pariview of the EasyStart Breeze 399's performance optimization features, including its compact size and significant current reduction capabilities.
3. Imọ ni pato
| Sipesifikesonu | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Awoṣe | EasyStart Breeze 399 |
| Brand | MICRO-AIR |
| Voltage | 100-120 VAC |
| Ti isiyi Rating | 30 Amps |
| Compressor Compatibility | Up to 13k-15k BTU RV AC units |
| Awọn iwọn (L x W x H) | 5.75 x 3.5 x 2 inches (isunmọ.) |
| Iwọn Nkan | 1.43 iwon |
| Iṣagbesori Iru | Oke Oke |
| Ipo Isẹ | Laifọwọyi |
| Ohun elo olubasọrọ | Ejò |
| UPC | 850049469210 |

Figure 3.1: Physical dimensions of the EasyStart Breeze 399 unit, illustrating its compact size for installation.
4. Eto ati fifi sori
Installation of the EasyStart Breeze 399 involves connecting the unit to your RV's air conditioner compressor. It is recommended that installation be performed by a qualified technician if you are not familiar with electrical wiring.
4.1. Atokọ fifi sori ẹrọ tẹlẹ
- Ensure all power to the RV and AC unit is disconnected at the source.
- Gather necessary tools: screwdriver set, wire strippers, multimeter, mounting hardware (included).
- Review the detailed installation guide provided with your kit.
4.2. Fifi sori Igbesẹ
- Remove AC Unit Cover: Carefully remove the cover of your RV's AC unit to access the compressor and wiring.
- Mount EasyStart: Securely mount the EasyStart Breeze 399 unit in a suitable location near the AC compressor, ensuring it is protected from elements.
- So awọn onirin: Follow the wiring diagram in the provided installation guide to connect the EasyStart unit to the compressor and power supply. Use the included Wago quick connectors for secure connections.
- Activate and Run Learning Sequence: Once wired, restore power and initiate the EasyStart's learning sequence. This process allows the unit to adapt to your specific compressor, optimizing its soft start performance. Refer to the detailed guide for specific activation steps.

Figure 4.1: Visual guide to the installation process, from mounting the unit to activating the learning sequence.


Nọmba 4.2: Alaye view of wire connections and the Wago connectors provided for a secure installation.
5. Awọn ilana Iṣiṣẹ
Once installed and the learning sequence is complete, the EasyStart Breeze 399 operates automatically. It intelligently manages the power supplied to your AC compressor during startup.
5.1. Isẹ deede
When your RV's thermostat calls for cooling, the EasyStart will engage. You may notice a slightly delayed and quieter startup of the compressor compared to its previous operation. This is normal and indicates the soft start technology is functioning correctly, reducing the initial current draw.
5.2. Generator Use
The primary benefit of the EasyStart is its ability to allow your RV AC to run on smaller generators. Ensure your generator meets the minimum wattage requirements for your AC unit with the EasyStart installed. The reduced starting current prevents generator overload and allows for more stable operation.

Figure 5.1: Benefits of using the EasyStart Breeze 399, including quieter operation and compatibility with portable generators.
6. Itọju
The MICRO-AIR EasyStart Breeze 399 is designed for minimal maintenance. Regular inspection of the unit and its connections is recommended.
- Ayewo Igbakọọkan: Annually, or before extended trips, visually inspect the EasyStart unit and its wiring for any signs of wear, damage, or loose connections.
- Jeki mimọ: Ensure the unit's exterior is free from excessive dust or debris. Use a soft, dry cloth for cleaning. Do not use harsh chemicals or abrasive materials.
- Idaabobo Ayika: While the unit is weatherproof, ensure its mounting location provides reasonable protection from direct, prolonged exposure to extreme weather conditions.
7. Laasigbotitusita
If you encounter issues with your EasyStart Breeze 399, refer to the following common troubleshooting steps. For complex issues, contact customer support.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| AC not starting or tripping breaker |
|
|
| Ẹka ti ko ni agbara lori |
|
|
| AC still loud on startup |
|
|
8. Atilẹyin ọja ati Support
The MICRO-AIR EasyStart Breeze 399 comes with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your product or visit the official MICRO-AIR webojula.
8.1. Onibara Support
For technical assistance, installation questions, or troubleshooting beyond this manual, please contact MICRO-AIR customer support. Contact information can typically be found on the product packaging or the official brand webojula.
O tun le ṣàbẹwò awọn MICRO-AIR Store on Amazon fun afikun oro ati ọja alaye.
Awọn iwe aṣẹ ti o jọmọ - EasyStart Breeze 399
![]() |
EasyStart FLEX Quick Installation Guide Installation guide for the Micro-Air EasyStart FLEX soft starter, covering wire identification, wiring procedures, and system learning. |
![]() |
EasyStart Troubleshooting: System Not Cooling Guide A comprehensive troubleshooting guide for Micro-Air EasyStart systems when the air conditioning is not cooling. Includes initial steps, LED diagnostics, voltage checks, and further resources. |
![]() |
Micro-Air EasyStart Home AC Wiring Installation Guide Comprehensive guide for installing the Micro-Air EasyStart system in various home air conditioning units. Covers safety precautions, system identification, component identification, wiring instructions for different system types (including Comfort Alert and Emerson Comfort Control), and troubleshooting. |
![]() |
Ìwé Ìtọ́sọ́nà Fífi Sílẹ̀ EasyStart 364 & 368 Soft Starter | Micro-Air Ìwé ìtọ́sọ́nà ìfisílé gbogbogbò fún àwọn ohun èlò ìbẹ̀rẹ̀ onírọ̀rùn Micro-Air EasyStart 364 (tón 3) àti 368 (tón 6). Ó ní àwọn ìtọ́ni àtúnṣe, àwòrán wáyà, ètò ìfọ́mọ́ra, ìṣòro, àti ìwífún nípa fiusi. |
![]() |
Micro-Air EasyStart Bluetooth Manual User manual and diagnostic guide for the Micro-Air EasyStart Bluetooth soft starter, covering app connectivity, system status, fault control, and firmware updates. |
![]() |
Itọsọna Fifi sori ẹrọ Awọn Waya AC EasyStart Home Ìtọ́sọ́nà ìfisílé gbogbogbò fún Micro-Air EasyStart ASY-364 àti ASY-368, àlàyé àwọn ìṣọ́ra ààbò, ìdámọ̀ àwọn ẹ̀yà ara, àwọn ìlànà wáyà ìgbésẹ̀-ní-ìgbésẹ̀, àti àwọn ìlànà pàtó fún àwọn ìṣètò ètò onírúurú. |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.





