Schneider Electric DPE18U7

Schneider Electric DPE18U7 Easy TeSys IEC Contactor User Manual

Model: DPE18U7

1. Ifihan

This manual provides essential information for the safe and efficient use of the Schneider Electric DPE18U7 Easy TeSys IEC Contactor. This 3-pole contactor is designed for motor control applications up to 18A/690V AC-3, specifically rated for 7.5 HP at 480V. It features a 240V 50/60Hz AC coil and includes 1 normally open (NO) and 1 normally closed (NC) built-in auxiliary contacts. The compact design (45mm width) allows for versatile mounting options, including DIN-rail or screw fixing. The DPE18U7 is certified to multiple standards, including IEC, UL, and CSA.

Schneider Electric Easy TeSys Contactor with text 'Quality you can trust'

Figure 1: Schneider Electric Easy TeSys Contactor, highlighting its robust design and quality.

2. Alaye Aabo

IKILO: Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. This product must be installed and wired in accordance with national and local electrical codes.

  • Nigbagbogbo ge asopọ agbara ṣaaju fifi sori ẹrọ, ṣiṣẹ, tabi yọ olubasọrọ kuro.
  • Rii daju didasilẹ to dara lati ṣe idiwọ mọnamọna itanna.
  • Lo ohun elo aabo ti ara ẹni ti o yẹ (PPE) nigbati o n ṣiṣẹ pẹlu awọn eto itanna.
  • Verify all connections are secure and correctly wired before applying power.
  • Ma ṣe ṣisẹ olubasọrọ ti o ba han pe o bajẹ tabi aiṣedeede.

3. Ọja Ipariview

The DPE18U7 Easy TeSys IEC Contactor is a reliable component for controlling electrical motors in various applications such as HVAC systems, pumps, and compressors. Its compact design and robust construction ensure stable and durable operation, protecting the internal components from dust and environmental elements.

Iwaju view of the Schneider Electric DPE18U7 Contactor showing terminals 1L1, 3L2, 5L3, 13 NO, A1, 14 NO, A2, 2T1, 4T2, 6T3

olusin 2: Iwaju view of the DPE18U7 Contactor, illustrating the main power terminals (1L1, 3L2, 5L3, 2T1, 4T2, 6T3), auxiliary contacts (13 NO, 14 NO), and coil terminals (A1, A2).

Apa view of the Schneider Electric DPE18U7 Contactor showing mounting features

olusin 3: Apa view of the DPE18U7 Contactor, highlighting its compact form factor and DIN-rail mounting capability.

Awọn ẹya pataki:

  • 3-Pole Contactor: Suitable for three-phase motor control.
  • Coil Voltage: 240V AC 50/60Hz for control circuit.
  • Awọn olubasọrọ Iranlọwọ: Integrated 1NO + 1NC contacts for signaling and interlocking.
  • Iṣagbesori: Flexible DIN-rail mounting or screw fixing.
  • Apẹrẹ Iwapọ: 45mm width for space-saving installations.
  • Awọn idiwọn: Conforms to IEC, UL, and CSA standards.
Diagram showing features and benefits of Easy TeSys Contactors including IEC, CSA, UL & cUL approved, IP20 finger-safe, 1 NO aux included, 1M electrical operations, marking plate, easy documentation, easy to install, compact design, coil voltages, panel/DIN rail mount, 45mm wide.

Figure 4: Detailed features and benefits of the Easy TeSys Contactor series.

4. Eto & Fifi sori

Proper installation is crucial for the safe and reliable operation of the contactor. Ensure all power is disconnected before proceeding.

4.1 Iṣagbesori

The DPE18U7 contactor can be mounted on a standard 35mm DIN-rail or secured using screws. Choose a mounting location that is free from excessive vibration, moisture, and extreme temperatures.

  • DIN-Rail iṣagbesori: Snap the contactor onto the DIN-rail by aligning the top clip and pressing down firmly until it clicks into place.
  • Ṣiṣatunṣe skru: Use appropriate screws to secure the contactor through the designated mounting holes on the base.

4.2 Awọn isopọ onirin

The contactor utilizes screw clamp terminals for secure wiring. Refer to the terminal markings on the device for correct connections.

  1. Power Circuit (Main Contacts): Connect the incoming three-phase power lines to terminals 1L1, 3L2, and 5L3. Connect the motor load lines to terminals 2T1, 4T2, and 6T3.
  2. Ìṣàkóṣo Ìṣàkóso (Kóólì): Connect the 240V AC control voltage to terminals A1 and A2. Ensure the correct voltage is applied to the coil.
  3. Awọn olubasọrọ Iranlọwọ: The built-in 1NO (Normally Open) and 1NC (Normally Closed) auxiliary contacts can be used for control logic, signaling, or interlocking. Refer to the markings (e.g., 13 NO, 14 NO) for specific connections.

Ensure all wire insulation is stripped to the correct length and that wires are fully inserted into the terminals before tightening the screws. Over-tightening can damage terminals, while under-tightening can lead to loose connections and overheating.

4.3 ẹya ẹrọ Integration

The DPE18U7 is compatible with various Schneider Electric accessories to enhance functionality:

  • Overload Relay (e.g., DPER16): Essential for motor protection against overcurrent. Mounts directly to the contactor.
  • Manual Motor Starter (e.g., GP2E16): Provides motor protection and manual control.
  • Auxiliary Contact Block (e.g., DPEAN11): For additional auxiliary contacts if needed.
  • Reversing Kit (e.g., LAD9R1): For reversing motor direction.
Schneider Electric Easy TeSys Thermal Overload RelaySchneider Electric DPE18U7 Easy TeSys IEC ContactorSchneider Electric DPEAN11 Auxiliary Contact Block

Olusin 5: Examples of compatible accessories: Thermal Overload Relay, Contactor, and Auxiliary Contact Block.

5. Isẹ

The DPE18U7 contactor operates by energizing its coil, which then closes the main power contacts, allowing current to flow to the connected motor. When the coil is de-energized, the contacts open, interrupting power to the motor.

  • Gbigbe okun: Apply 240V AC to the coil terminals A1 and A2. This will cause the main contacts (1L1-2T1, 3L2-4T2, 5L3-6T3) to close, and the NO auxiliary contacts to close, while the NC auxiliary contacts open.
  • Mimu okun kuro: Remove the 240V AC supply from the coil terminals A1 and A2. This will cause the main contacts to open, and the NO auxiliary contacts to open, while the NC auxiliary contacts close.

The auxiliary contacts can be integrated into control circuits for status indication, interlocking with other devices, or creating start/stop logic.

6. Itọju

Regular maintenance helps ensure the longevity and reliable performance of your DPE18U7 contactor. Always disconnect power before performing any maintenance.

  • Ayewo wiwo: Lorekore ayewo awọn contactor fun eyikeyi ami ti ara bibajẹ, discoloration, tabi alaimuṣinṣin awọn isopọ.
  • Ninu: Keep the contactor free from dust, dirt, and debris. Use a dry, soft cloth or compressed air for cleaning. Do not use liquid cleaners.
  • Titọpinpin: Check the tightness of all screw clamp terminals to ensure good electrical contact. Re-tighten if necessary, but do not over-tighten.
  • Olubasọrọ Wear: While the contacts are designed for long life, excessive arcing or frequent operation under heavy loads can cause wear. If significant pitting or erosion is observed, the contactor may need replacement.

7. Laasigbotitusita

If the contactor is not functioning as expected, perform the following checks:

IsoroOwun to le FaOjutu
Olubasọrọ ko ni agbara (awọn olubasọrọ ko tii)Ko si iṣakoso voltage sí ìkọ́lé (A1-A2)
Vol coil ti ko tọtage
Ìsopọ̀ tó bàjẹ́
Loose onirin awọn isopọ
Verify 240V AC supply to A1-A2
Ensure correct coil voltage ti lo
Test coil resistance; replace contactor if coil is open/shorted
Check and tighten all control circuit wiring
Contactor hums raraLoose laminations
Foreign object in magnet assembly
Vol coil ti ko tọtage
Ropo olubasọrọ
Ṣayẹwo ki o si yọ eyikeyi idena
Verify correct coil voltage
Contactor contacts remain open or closedMechanical abuda
Welded awọn olubasọrọ
Damaged return spring
Inspect for obstructions; replace if binding persists
Ropo olubasọrọ
Ropo olubasọrọ
Overheating at terminalsAwọn isopọ alaimuṣinṣin
Overcurrent condition
Ailokun onirin
Tighten terminal screws
Check motor load and protection devices
Ensure wiring gauge is appropriate for current

8. Awọn pato

Detailed technical specifications for the Schneider Electric DPE18U7 Easy TeSys IEC Contactor:

IwaIye
BrandSchneider Electric
AwoṣeDPE18U7
Awọn ọpá3P (3 Normally Open)
Rated Operational Current (AC-3)18 Amps at <= 690V
Motor Power (AC-3)7.5 HP at 480V
Coil Voltage240V AC 50/60Hz
Awọn olubasọrọ Iranlọwọ1 NO + 1 NC (Built-in)
Iṣagbesori IruDIN-rail or Screw Fixing
Ebute IruDabaru Clamp Awọn ibudo
Awọn iwọn (L x W x H)3.03 x 1.77 x 3.39 inches (77 x 45 x 86 mm)
Iwọn0.35 kilogram (0.77 lbs)
Ohun eloṢiṣu
Awọn ajohunšeIEC, UL, CSA
Table of 3-pole contactor standard power ratings for motors conforming to UL and CSA Standards for North American market, showing single-phase and three-phase HP ratings across various voltages, associated cable types, continuous current, reference, and weight.

Figure 6: Standard power ratings for 3-pole contactors conforming to UL and CSA standards.

9. Atilẹyin ọja & Atilẹyin

The Schneider Electric DPE18U7 Easy TeSys IEC Contactor comes with an Atilẹyin ọja olupilẹṣẹ oṣu mejila láti ọjọ́ tí a rà á. Àtìlẹ́yìn yìí bo àwọn àbùkù nínú àwọn ohun èlò àti iṣẹ́ ọwọ́ lábẹ́ lílo àti iṣẹ́ déédéé.

For technical support, warranty claims, or additional product information, please visit the official Schneider Electric webojula tabi kan si wọn onibara iṣẹ Eka. O tun le ri alaye siwaju sii ati awọn ọja ni awọn Ile itaja ina Schneider lori Amazon.

© 2024 Schneider Electric. Gbogbo awọn ẹtọ wa ni ipamọ.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.