The MustOOL MT336 is a versatile 2-in-1 True RMS Digital Clamp Meter and Oscilloscope. This device allows for non-contact measurement of AC current waveforms, DC/AC voltage, resistance, capacitance, frequency, and temperature. It features a waveform display for quick analysis and includes functions like diode testing and continuity checks. Designed for safety and efficiency, it is an essential tool for electrical measurements.

MustOOL MT336 Digital Clamp Meter held in hand, displaying '600' on its screen.

Figure 1: MustOOL MT336 Digital Clamp Meter in use, showing its display.

2. Alaye Aabo

Máa tẹ̀lé àwọn ìlànà ààbò nígbà gbogbo nígbà tí o bá ń lo àwọn ohun èlò ìdánwò iná mànàmáná. Àìṣe bẹ́ẹ̀ lè yọrí sí ìkọlù iná mànàmáná, ìpalára, tàbí ìbàjẹ́ sí mita tàbí ohun èlò tí a ń dán wò.

  • Maṣe kọja awọn ifilelẹ titẹ sii ti o pọju fun iṣẹ eyikeyi.
  • Ensure the test leads are in good condition and properly connected before use.
  • Do not use the meter if it appears damaged or if the battery cover is not properly closed.
  • Ṣọra pupọ nigbati o ba n ṣiṣẹ pẹlu voltages loke 60V DC tabi 30V AC RMS.
  • Always disconnect power to the circuit before making resistance, capacitance, or diode measurements.
  • Yọ awọn okun idanwo kuro ninu mita naa ki o to ṣii apoti batiri naa.
Pada view of the MustOOL MT336 clamp meter, showing a warning label about removing test leads before opening the case and battery specifications.

olusin 2: Ẹyìn view of the MT336, highlighting safety warnings and battery information.

3. Ọja irinše

The MustOOL MT336 clamp meter includes the following main components:

  • Clamp Ẹrẹ: For non-contact AC current measurement.
  • Nfa: Ṣii ati tilekun clamp bakan.
  • Ifihan LCD: Shows measurement readings, waveforms, and function indicators.
  • Awọn bọtini iṣẹ: For selecting modes, ranges, and other features.
  • Input Jacks (COM, VΩHz): Fun sisopọ awọn itọsọna idanwo fun voltage, àwọn ìwọ̀n resistance, capacitance, ìgbagbogbo, diode, àti ìtẹ̀síwájú.
  • Temperature Probe Input: For connecting the included temperature probe.
MustOOL MT336 Digital Clamp Mita ti o nfihan cl naaamp àgbọ̀n, ìfihàn, àti àwọn bọ́tìnì ìṣàkóso.

Olusin 3: Pariview of the MT336 clamp meter, showing its main parts.

4. Eto

4.1 Fifi sori batiri

  1. Ensure the meter is powered off and no test leads are connected.
  2. Wa yara batiri ni ẹhin mita naa.
  3. Yọ ideri iyẹwu batiri kuro.
  4. Insert three AAA 1.5V batteries, observing correct polarity.
  5. Rọpo ideri kompaktimenti batiri ki o ni aabo pẹlu dabaru.

4.2 Nsopọ Awọn itọsọna Igbeyewo

Fun voltage, resistance, capacitance, frequency, diode, and continuity measurements:

  • Fi dudu igbeyewo asiwaju sinu COM (Wọpọ) ìsopọ̀ ìtẹ̀wọlé.
  • Fi asiwaju igbeyewo pupa sinu VΩHz Jack input.

For temperature measurements, connect the temperature probe to the designated input ports.

5. Awọn ilana Iṣiṣẹ

5.1 Agbara Tan / Pa

Press the power button to turn the meter on. The meter will automatically shut down after 15 minutes of inactivity to conserve battery life. Press the power button again to turn it off manually.

5.2 AC Wiwọn lọwọlọwọ (Clamp Iṣẹ́)

  1. Select the AC current mode (usually indicated by 'A~' or a similar symbol).
  2. Tẹ okunfa lati ṣii clamp bakan.
  3. Fi adarí kan ṣoṣo (kì í ṣe okùn agbára pẹ̀lú àwọn wáyà púpọ̀) sínú cl náàamp bakan.
  4. Release the trigger to close the jaw securely around the conductor.
  5. Read the AC current value and waveform on the display.
MustOOL MT336 Digital Clamp Meter clamping around a single electrical wire, displaying a waveform on its screen.

Figure 4: Measuring AC current and waveform using the clamp iṣẹ.

5.3 AC / DC Voltage Idiwon

  1. So awọn itọsọna idanwo pọ gẹgẹ bi a ti ṣalaye ni Abala 4.2.
  2. Yan iwọn didun ti o yẹtage mode (DCV or ACV).
  3. Touch the red and black test probes to the points where voltage ni ki won won.
  4. Ka voltage value on the display. For AC voltage, the waveform may also be displayed.
MustOOL MT336 Digital Clamp Meter with test leads connected to a power outlet, displaying an AC voltage igbi.

Àwòrán 5: Wíwọ̀n ìpele ACtage and waveform from a power outlet.

5.4 Resistance, Capacitance, Frequency, Diode, and Continuity

For these functions, ensure the circuit is de-energized before connecting the test leads. Select the desired function using the mode buttons and follow standard measurement procedures for multimeters.

  • Agbára ìdènà (Ω): Measures the electrical resistance of a component.
  • Agbara (F): Measures the capacitance of capacitors.
  • Igbohunsafẹfẹ (Hz): Ó ń wọn ìgbóná ìgbóná ìró AC kan.
  • Idanwo Diode: Checks the forward voltage silẹ ti a ẹrọ ẹlẹnu meji.
  • Idanwo Ilọsiwaju: Indicates if a circuit is complete with a low resistance path (typically with an audible beep).

5.5 Wiwọn iwọn otutu

Connect the temperature probe to the meter's designated input. Select the temperature function and place the probe tip on the object or area to be measured. The temperature will be displayed in Celsius or Fahrenheit.

6. Itọju

6.1 Ninu

Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Keep the input terminals free of dirt and moisture.

6.2 Batiri Rirọpo

When the low battery indicator appears on the display, replace the batteries as described in Section 4.1. Use three new AAA 1.5V batteries.

6.3 Ibi ipamọ

If the meter is not used for an extended period, remove the batteries to prevent leakage and damage. Store the meter in a cool, dry place away from direct sunlight.

7. Laasigbotitusita

IsoroOwun to le FaOjutu
Mita ko ni agbara lori.Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ.Ropo awọn batiri, aridaju ti o tọ polarity.
No reading or "OL" displayed.Open circuit, out of range, or incorrect function selected.Check connections, select appropriate range/function, or ensure circuit is closed.
Awọn kika ti ko pe.Low battery, dirty test leads/terminals, or external interference.Replace batteries, clean leads/terminals, move away from strong electromagnetic fields.
Waveform not displayed correctly.Signal frequency too high/low, or incorrect range.Ensure signal is within 1kHz ACV/ACA. Adjust range if available.

8. Awọn pato

Awọn Ni pato:

  • Ifihan: 128 x 64 LCM with white backlight on black screen (45mm x 35mm)
  • Agbara: 3 x AAA 1.5V awọn batiri
  • Tiipa Aifọwọyi: Approximately 15 minutes of inactivity
  • Ibi ipamọ data: 100 data points, 10 waveforms
  • Awọn iwọn: 78mm x 210mm x 36mm
  • Ìwúwo: 220g (lai awọn batiri)
  • Ayika Ṣiṣẹ: 0°C to 40°C; <75% RH
  • Ayika Ibi ipamọ: -10°C to 60°C; <90% RH
  • Iwọn Aabo: CAT II 600V

Measurement Specifications (Accuracy ±(rdg + dgt)):

IšẹIbiti oYiye
DC Voltage400mV / 4V / 40V / 400V / 600V± (1.5% + 10)
AC Voltage (TRMS)4V / 40V / 400V / 600V± (2.0% + 10)
AC Lọwọlọwọ40A / 400A± (2.5% + 10)
Atako400Ω / 4kΩ / 40kΩ / 400kΩ / 4MΩ / 40MΩ± (1.0% + 5)
Agbara4nF / 40nF / 400nF / 4uF / 400uF / 4mF± (4.0% + 10)
Igbohunsafẹfẹ9.999Hz si 30kHz± (2.0% + 10)
Iwọn otutu-20 ℃ si 250 ℃± (2.0% + 3)
Idanwo DiodeṢii Circuit voltage approx. 3V, max test current approx. 2mAN/A
Igbeyewo IlọsiwajuJudgment resistance approx. 50ΩN/A
Bandiwidi afọwọṣeACV / ACA 1 kHzN/A

9. Atilẹyin ọja ati Support

For warranty information and technical support, please refer to the official MustOOL webojula tabi kan si alagbata rẹ. Tọju iwe-ẹri rira rẹ bi ẹri rira.

The package includes: 1x Clamp Meter, 1x Pair of Test Leads, 1x English User Manual, 1x Temperature Probe.

© 2023 MustOOL. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.