This manual provides detailed instructions for the installation, operation, and maintenance of the COMAP FLEXODESIGN Thermostatic Valve, model L234006001. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Apejuwe ọja

The COMAP FLEXODESIGN Thermostatic Valve is designed for central connection to towel dryer radiators without integrated fittings, utilizing a two-pipe connection system. This valve is adaptable for various configurations, allowing connection from the floor or wall. It is compatible with copper, mild steel, stainless steel, PER, and multi-layer pipes using appropriate 3/4" Eurocone compression fittings.

COMAP FLEXODESIGN Thermostatic Valve installed on a towel dryer radiator in a modern bathroom.

Figure 1: COMAP FLEXODESIGN Thermostatic Valve installed on a towel dryer radiator.

3. Key Awọn ẹya ara ẹrọ

  • Apẹrẹ Iyipada: Can be configured for straight or angled connections without the need for tools.
  • Fifi sori ẹrọ Rọ: The thermostatic head can be installed on either the right or left side.
  • Reversible Flow: The product is reversible, allowing it to function correctly even if the flow direction is inverted.
  • Integrated Kit: Includes the thermostatic head, body, and cover for a cohesive design with decorative towel dryers.
  • Iwọn Iwapọ: Features a reduced footprint for discreet integration.
Diagram showing the COMAP thermostatic valve with arrows indicating reversible flow direction.

Figure 2: The valve's reversible flow capability.

4. Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Nọmba awoṣeL234006001
BrandCOMAP
Àwọ̀Funfun
Dimensions (Thermostatic Head)M30 x 1.5
FọọmuOrientable (Straight or Angled)
Ijinna aarin50 mm
Asopọmọra IruRight or Left / Wall or Floor
Radiator ConnectionMale 1/2"
Pipe Asopọ3/4" Eurocone (with adapted compression fittings)
Ipa ti o pọju10 igi
Iwọn Iyatọ Iyatọ ti o pọju0.6 igi
Maximum Temperature (Permanent)110°C
Maximum Temperature (Peak)130°C
Agbara IruHydraulic Force Powered
Awọn irinše to wa1 thermostatic àtọwọdá

5. Eto ati fifi sori

The COMAP FLEXODESIGN valve is designed for easy installation on towel dryer radiators. It can be configured for various pipe connections (copper, mild steel, stainless steel, PER, multi-layer) using appropriate 3/4" Eurocone compression fittings.

5.1. Iṣeto ni Aw

  • Straight or Angled: The valve can be transformed from a straight to an angled configuration without tools to suit your installation needs.
  • Ipo Ori: The thermostatic head can be mounted on either the right or left side of the valve body.
  • Pipe Entry: The valve supports pipe connections coming from the floor or the wall.
Image showing the COMAP thermostatic valve installed on a radiator with pipes coming from the wall.

Olusin 3: Example of wall-mounted pipe connection.

5.2. Connection to Radiator and Pipes

  1. Ensure the heating system is depressurized and drained before beginning installation.
  2. Connect the valve's Male 1/2" connection to the radiator.
  3. Attach the appropriate 3/4" Eurocone compression fittings to your copper, mild steel, stainless steel, PER, or multi-layer pipes.
  4. Connect the pipes to the valve using the compression fittings. Ensure all connections are tight to prevent leaks.
  5. The valve is reversible; if the flow direction is inverted, the product will still function correctly.
Close-up image of the COMAP thermostatic valve showing its connections.

Nọmba 4: Alaye view of valve connections.

6. Awọn ilana Iṣiṣẹ

The COMAP FLEXODESIGN thermostatic valve automatically regulates the flow of hot water to the radiator based on the ambient room temperature and the setting on the thermostatic head.

6.1. Ṣiṣeto iwọn otutu

  • Rotate the thermostatic head to the desired temperature setting. The head typically has numerical or symbolic markings corresponding to different temperature levels.
  • A higher number or symbol generally indicates a warmer setting, while a lower number or symbol indicates a cooler setting.
  • The valve will then adjust the hot water flow to maintain the selected room temperature.
Close-up of the COMAP thermostatic head with temperature settings.

Figure 5: Thermostatic head with adjustable settings.

7. Itọju

The COMAP FLEXODESIGN thermostatic valve requires minimal maintenance. Regular checks can help ensure its longevity and efficient operation.

  • Ninu: Wipe the exterior of the valve and thermostatic head with a soft, damp asọ. Ma ṣe lo abrasive ose tabi epo.
  • Ṣayẹwo iṣẹ ṣiṣe: Periodically rotate the thermostatic head through its full range of settings to ensure it moves freely and is not stuck.
  • Ayẹwo ti o jo: Regularly check all connections for any signs of water leakage. Address any leaks immediately.

8. Laasigbotitusita

This section addresses common issues you might encounter with your thermostatic valve.

IsoroOwun to le FaOjutu
Radiator not heating or heating insufficiently.Thermostatic head set too low.
Valve pin stuck.
Air in the radiator.
Increase the setting on the thermostatic head.
Remove the thermostatic head and gently press the valve pin to ensure it moves freely. If stuck, it may require professional attention.
Bleed the radiator to release trapped air.
Radiator is too hot despite low setting.Thermostatic head faulty or incorrectly installed.
Valve pin stuck open.
Check if the thermostatic head is properly seated. If the issue persists, the head may need replacement.
Remove the thermostatic head and check if the valve pin is fully retracted when the head is removed.
Jíjá omi láti inú àwọn ìsopọ̀.Loose awọn isopọ.
Damaged seals/fittings.
Tighten connections carefully. Do not overtighten.
Replace damaged seals or compression fittings. Ensure proper sealing tape or compound is used during installation.

9. Atilẹyin ọja ati Support

Information regarding spare parts availability is not provided in the product details. For warranty claims or technical support, please contact your COMAP retailer or the official COMAP customer service. Keep your purchase receipt as proof of purchase.

Note: The product details indicate "Batterie(s) / Pile(s) incluse(s): Oui" and "Batterie(s) / Pile(s) requise(s): Oui" and "Composition de la pile: Alcaline". This seems contradictory for a hydraulic valve. It is assumed this is an error in the source data, and the valve operates purely on hydraulic force as stated in "Type d'alimentation: Alimenté par Force Hydraulique". No batteries are expected for this type of mechanical thermostatic valve.

© 2024 COMAP. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.