1. Ifihan
The Gima Vega Uno Surgical Aspirator is a compact and reliable medical device designed for the aspiration of liquids such as mucus, phlegm, and blood from nasal, oral, or tracheal passages in both adults and children. This device is suitable for minor surgical procedures and post-operative home care. It features instant suction intensity adjustment and a robust design for professional use.

Image 1.1: The Gima Vega Uno Aspirator is recommended for nasal, oral, or tracheal fluid aspiration in adults or children.
2. Alaye Aabo
Please read all instructions carefully before using the Gima Vega Uno Surgical Aspirator. Failure to follow safety guidelines may result in injury or damage to the device.
- Rí i dájú pé a gbé ẹ̀rọ náà sí orí ilẹ̀ tí ó dúró ṣinṣin nígbà tí a bá ń ṣiṣẹ́.
- Ma ṣe fi ẹya akọkọ sinu omi tabi omi miiran.
- Jeki ẹrọ naa kuro ni awọn orisun ooru ati oorun taara.
- Only use accessories and replacement parts approved by GIMA.
- Regularly inspect all components for damage or wear before each use.
- The electrical and thermal parts of the aspirator are insulated for safety. Do not attempt to open or repair the main unit. Refer servicing to qualified personnel.
- Nigbagbogbo ge asopọ ipese agbara ṣaaju ṣiṣe mimọ tabi ṣiṣe itọju.
- This device is intended for medical use. Consult a healthcare professional for proper usage techniques and medical advice.

Image 2.1: The Gima Vega Uno features insulated and safe electrical parts.
3. Ọja Ipariview
3.1 irinše
The Gima Vega Uno Surgical Aspirator typically includes the following components:
- Aspirator main unit
- Collection container (Makrolon, 1L or 2L)
- Suction tubes (silicone, autoclavable)
- Isọnu isọnu
- Conical connector for catheters
- Ilana itọnisọna

Image 3.1: Diagram of the Gima Vega Uno components and controls.
3.2 Key Awọn ẹya ara ẹrọ
- Silent and High-Flow Pumps: Designed for quiet operation and efficient fluid aspiration.
- Maintenance-Free Pumps: Ensures long-lasting performance without frequent servicing.
- Instant Suction Intensity Adjustment: Allows precise control over aspiration strength.
- Unbreakable Makrolon Container: Durable collection container available in 1L or 2L capacity.
- Autoclavable Components: The collection container and silicone tubes can be sterilized at 121°C.
- Liquid Level Control Valve: Prevents overflow into the main unit.
- Hydrophobic, Antibacterial, Anti-reflux Filter: Provides enhanced hygiene and protection.
- Apẹrẹ Iwapọ: Rọrun lati mu ati fipamọ.

Image 3.2: The aspirator features silent, high-flow, and maintenance-free pumps.

Image 3.3: The filter is hydrophobic, antibacterial, and anti-reflux.
4. Awọn ilana iṣeto
- Yọọ kuro: Fi ìṣọ́ra yọ gbogbo àwọn ohun èlò kúrò nínú àpótí náà. Ṣàyẹ̀wò fún ìbàjẹ́ èyíkéyìí tí ó bá hàn gbangba.
- Assemble Collection Container: Ensure the lid of the collection container is securely fastened.
- Connect Suction Tubes: Attach one end of the silicone suction tube to the 'PATIENT' port on the collection container lid. Connect the other end to the conical connector for the catheter.
- Connect Aspirator to Container: Connect the 'VACUUM' port on the collection container lid to the suction inlet on the main aspirator unit. Ensure all connections are tight to prevent air leaks.
- Fi Ajọ sii: Place the disposable filter between the collection container and the main unit, ensuring it is correctly oriented as per the markings.
- Asopọ agbara: Plug the power cord into a suitable electrical outlet (230 Volt).

Image 4.1: The Gima Vega Uno Aspirator ready for use.
5. Awọn ilana Iṣiṣẹ
- Agbara Tan: Press the ON/OFF switch to turn on the aspirator. The indicator light will illuminate.
- Adjust Suction Intensity: Use the regulation knob to adjust the desired suction intensity. Monitor the vacuum gauge (kPa/Bar) for the current suction level.
- Perform Aspiration: Carefully insert the catheter connected to the suction tube into the patient's nasal, oral, or tracheal passage as instructed by a healthcare professional.
- Monitor Collection Container: Observe the liquid level in the collection container. The integrated valve prevents overflow. Do not allow the container to overfill.
- Agbara Pa: Once aspiration is complete, press the ON/OFF switch to turn off the device.
- Ge asopọ: Yọọ okun agbara lati inu iṣan.
6. Itọju ati Cleaning
Proper maintenance and cleaning are crucial for the longevity and hygienic operation of your Gima Vega Uno Aspirator.
- Ninu ojoojumọ: After each use, empty and clean the collection container. The Makrolon container and silicone tubes are autoclavable at 121°C. Wash them with warm water and a mild detergent, then rinse thoroughly.
- Isọdọmọ: For sterilization, place the cleaned container and tubes in an autoclave at 121°C according to standard sterilization protocols.
- Iyipada Ajọ: The disposable filter should be replaced regularly, or immediately if it becomes wet or visibly soiled. Do not attempt to clean and reuse the filter.
- Àyẹ̀wò Ọpọn Irin: Regularly inspect silicone tubes for any signs of wear, cracks, or blockages. If mold or persistent residue is observed inside the tubes, they should be thoroughly cleaned or replaced.
- Ode Ninu: Mu ese ita ti akọkọ kuro pẹlu asọ, damp asọ. Ma ṣe lo awọn olutọpa abrasive tabi fi omi mọlẹ kuro ninu omi.

Image 6.1: The aspirator features self-cleaning vessels for easy maintenance.
7. Laasigbotitusita
If you encounter issues with your Gima Vega Uno Aspirator, refer to the following common problems and solutions:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ko si afamora tabi afamora alailagbara |
|
|
| Ẹrọ ko ni tan-an |
|
|
| Ariwo dani nigbati isẹ |
|
|
8. Awọn pato
| Sipesifikesonu | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Olupese | CA-MI SRL |
| Nọmba awoṣe | 28209 |
| Iwọn Nkan | 2.2 kilo |
| Ọja Mefa | 25 x 19 x 16.5 cm |
| Volume of Item | 1 Litre (container) |
| Voltage | 230 folti |
| Pataki Awọn ẹya ara ẹrọ | Iwapọ |
| Awọn irinše to wa | Aspirator, manual |
| Awọn batiri ti a beere | Rara |
9. Atilẹyin ọja ati Support
For warranty information, technical support, or to purchase replacement parts, please contact GIMA customer service or your authorized distributor. Keep your purchase receipt as proof of purchase.