The Oumefar Timer Relay Module is a versatile time delay relay converter designed for various applications, including automotive control systems and general electrical equipment. It features adjustable on-time and off-time settings, supports both mon (single) and cycle modes, and includes reverse input protection.
Awọn ẹya pataki pẹlu:
- Iṣẹ Idaabobo: Supports reverse input protection.
- Trigger Button Switch: For initiating the timing sequence.
- Adjustable Time: Both "on" and "off" times are adjustable.
- Awọn ọna meji: Mon mode (single trigger) and Cycle mode (continuous operation).
- Ohun elo jakejado: Suitable for timer operating equipment, robotics, automation, PLC development, smart home systems, and electronic development.
Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Brand | Oumefar |
| Nọmba awoṣe | Oumefarpw47ecz0iy38625-05 |
| Max lọwọlọwọ | 10A |
| Awọn iwọn (Itosi.) | 70mm (Ipari) x 20mm (Iwọn) x 18mm (Iga) |

Image: Dimensions of the Oumefar Timer Relay Module.
| Iṣagbewọle Voltage | Adijositabulu Time Range |
|---|---|
| DC 5V | 0-30 Minutes, 0-24 Hours |
| DC 12V | 0-120 Minutes, 0-24 Hours |
| DC 24V | 0-15 Minutes, 0-30 Minutes |

Image: Available voltage options and their respective time adjustment ranges.
Eto ati fifi sori
Carefully follow these steps for proper setup and installation of the timer relay module.
- Ṣe idanimọ Awọn eroja: Familiarize yourself with the module's components as shown in the diagram below.
- Asopọ Ipese Agbara: Connect the power supply to the module. Ensure correct polarity to utilize the reverse input protection. The module supports DC 5V, 12V, or 24V depending on the specific model.
- Asopọmọra fifuye: Connect your load to the relay's output terminals (NC, COM, NO). Refer to the wiring diagram for proper connection.
- Time Range Selection: Use the jumper to select the time range.
- When the jumper is on "T", the time is normal.
- When the jumper is on "T/10", the time is divided by 10 (e.g., 10 minutes becomes 1 minute).
- Aṣayan Ipo Ṣiṣẹ: Use the jumper to select the desired working mode.
- When the jumper is on "Cycle", the module operates in infinite cycle mode.
- When the jumper is on "Mon", the module operates in single (monostable) mode.

Image: Labeled components of the timer relay module, showing potentiometers for 'on' and 'off' time adjustment, power indicator LED, and switch indicator LED.

Image: Detailed wiring diagram illustrating how to connect the module's power, load, and optional start button. It emphasizes not reversing the power supply polarity.

Image: Close-up of the module showing the jumpers for selecting time range and working mode.
Isẹ
Operating the Oumefar Timer Relay Module involves setting the desired time delays and triggering the module.
- Adjusting Delay Times: Use the two potentiometers on the module to adjust the "on" time and "off" time. Rotate them clockwise to increase the time and counter-clockwise to decrease it.
- Triggering the Module:
- Mon Mode (Single): After powering on, press the trigger switch (start button) once. The load will turn on, and after the set "on" delay time, it will turn off.
- Ipo Yipo: After powering on, press the trigger switch once. The load will cycle on and off according to the set "on" and "off" times. Press the trigger switch again to stop the cycle.
- Ipo Abojuto: The module includes a power indicator and a switch indicator LED to show its operational status.

Image: Potentiometers for fine-tuning the "on" and "off" delay periods.
Itoju
The Oumefar Timer Relay Module is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure longevity:
- Jeki mimọ: Ensure the module is free from dust and debris. Use a soft, dry cloth for cleaning.
- Awọn ipo Ayika: Operate the module within its specified temperature and humidity ranges. Avoid exposure to extreme conditions or corrosive environments.
- Awọn isopọ to ni aabo: Lokọọkan ṣayẹwo gbogbo awọn asopọ onirin lati rii daju pe wọn wa ni aabo ati ominira lati ipata.
- Rirọpo Ẹka: If longer delay times are required beyond the adjustable range, it may be possible to replace the capacitor or potentiometer with components of higher values. This should only be performed by qualified personnel.
Laasigbotitusita
If you encounter issues with your Oumefar Timer Relay Module, refer to the following common problems and solutions:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Module ko ni agbara lori. | Ipese agbara ti ko tọ voltage or polarity; loose connections. | Daju igbewọle voltage matches module requirements (5V, 12V, or 24V). Check power supply polarity. Ensure all power connections are secure. |
| Load does not activate/deactivate. | Incorrect load wiring; faulty load; incorrect mode selection; trigger not activated. | Check load wiring against the diagram (NC, COM, NO). Test the load independently. Confirm jumper settings for "Mon" or "Cycle" mode. Ensure the trigger button is pressed. |
| Timing is inaccurate or not adjustable. | Incorrect time range jumper setting; faulty potentiometer. | Verify the time range jumper is set correctly (T or T/10). Ensure potentiometers are rotated within their limits. |
| Module cycles continuously in Mon mode. | Jumper incorrectly set to "Cycle" mode. | Adjust the working mode jumper to "Mon" for single operation. |
Atilẹyin ọja ati Support
Oumefar products are manufactured to high-quality standards. For specific warranty information, please refer to the product packaging or the retailer's policy where the product was purchased. For technical support or inquiries, please contact Oumefar customer service through their official channels or the retailer.
You can visit the Oumefar store for more information: Oumefar Store on Amazon.