KKmoon KKM828

KKmoon KKM828 2-in-1 Digital Multimeter with Oscilloscope User Manual

Model: KKM828

1. Ifihan

The KKmoon KKM828 is a versatile 2-in-1 device combining the functionalities of a digital multimeter and an oscilloscope. Designed for efficiency and accuracy, it features a 2.4-inch color display, a 1MHz bandwidth for AC voltage, and a 2.5Msps real-time sampling rate. This manual provides essential information for safe and effective operation of your KKM828 device.

2. Alaye Aabo

Please read and understand all safety instructions before using the device. Failure to follow these instructions may result in electric shock, fire, or damage to the device or other equipment.

  • Always ensure the device is in good working condition and free from damage before use.
  • Maa ko waye voltage or current that exceeds the maximum limits specified in the technical specifications.
  • Lo iṣọra nigbati o ba n ṣiṣẹ pẹlu voltages above 24V, as they pose a shock hazard. The device will emit an audible warning if the input voltage koja 24V.
  • Rí i dájú pé a yan iṣẹ́ àti ìwọ̀n tó yẹ kí a tó ṣe àwọn ìwọ̀n.
  • Rọpo awọn batiri ni kiakia nigbati ifihan batiri kekere ba han lati rii daju pe o peye awọn kika.
  • The device is equipped with double fuses (500mA/250V and 10A/250V) for protection. Do not bypass or use incorrect fuse types.
  • Do not operate the device in wet environments or explosive atmospheres.
  • Refer to the "Maintenance" section for proper cleaning and storage procedures.

3. Ọja Ipariview

The KKmoon KKM828 integrates a digital multimeter and an oscilloscope into a compact, handheld unit. Key components and features are detailed below.

3.1 Key Awọn ẹya ara ẹrọ

  • 2-in-1 Iṣẹ-ṣiṣe: Combines a digital multimeter and an oscilloscope.
  • Ifihan: 2.4-inch 320x240 LCM color screen for clear readings and waveform display.
  • Oscilloscope Performance: 1MHz ACV bandwidth, 2.5Msps real-time sampoṣuwọn ling.
  • Àwọn Iṣẹ́ Multimeter: Awọn iwọn AC/DC voltage, agbara AC/DC, resistance, capacitance, igbohunsafẹfẹ, iyipo iṣẹ, diode, ati ilosiwaju.
  • Ibi ipamọ data: Stores up to 100 sets of data and 10 waveforms.
  • Atẹlu olumulo: Silicone buttons and a pressure-sensitive dial for precise function selection.
  • Ergonomics: Integrated back bracket for a 60° viewigun igun.
  • Aabo: Double fuse protection (500mA/250V, 10A/250V) and input voltage ìkìlọ.

3.2 Device irinše

Wo aworan ni isalẹ fun atunyẹwoview of the device's main components.

KKmoon KKM828 Product Details: showing HD screen, function dial, and back bracket

Figure 1: KKM828 Product Details. This image highlights the device's HD color screen (01), the function dial for accurate gear changes (02), and the back bracket (03) for easy viewing.

  • Iboju HD: 2.4-inch color screen for clear display of measurements and waveforms.
  • Ṣiṣe ipe iṣẹ: Rotary switch for selecting measurement functions (voltage, current, resistance, etc.) and oscilloscope mode.
  • Buttons (F1-F4, R, S): Used for navigating menus, selecting ranges, holding data, and other specific functions.
  • Awọn Jacks ti nwọle: Terminals for connecting test leads for various measurements (e.g., VΩHz, mA, 10A, COM).
  • Àkọ́ ẹ̀yìn: Foldable stand for propping up the device at a 60° angle for convenient viewing.

4. Eto

4.1 Fifi sori batiri

The KKM828 requires three AA batteries for operation. Ensure the device is powered off before installing or replacing batteries.

  1. Wa ideri iyẹwu batiri ni ẹhin ẹrọ naa.
  2. Open the battery compartment cover by sliding or unscrewing it (if applicable).
  3. Insert three AA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  4. Pa ideri batiri naa ni aabo.

4.2 Titan / Pa a

To power on the device, rotate the function dial from the "OFF" position to any desired measurement function. To power off, rotate the dial back to the "OFF" position.

5. Awọn ilana Iṣiṣẹ

5.1 Multimeter Awọn iṣẹ

The KKM828 offers a comprehensive range of multimeter measurement capabilities. Always connect test leads correctly to the appropriate input jacks (e.g., COM, VΩHz, mA, 10A) for the selected function.

  • AC/DC Voltage Iwọn: Rotate the dial to the 'V~' or 'V=' position. Connect test leads in parallel with the circuit.
  • AC/DC Wiwọn lọwọlọwọ: Rotate the dial to the 'mA~', 'mA=', '10A~', or '10A=' position. Connect test leads in series with the circuit.
  • Iwọn Atako: Rotate the dial to the 'Ω' position. Ensure the circuit is de-energized before measuring resistance.
  • Iwọn Agbara: Rotate the dial to the 'mF' position. Discharge capacitors before measurement.
  • Iwọn Igbagbogbo ati Iwọn Iṣẹ: Rotate the dial to the 'Hz%' position.
  • Idanwo Diode: Rotate the dial to the 'Diode' position. Connect leads across the diode to check forward voltage ju.
  • Idanwo Ilọsiwaju: Rotate the dial to the 'Continuity' position. The device will beep if resistance is below approximately 50Ω.
KKmoon KKM828 Multimeter Functions: showing frequency, duty cycle, diode test, and continuity test

Figure 2: Multimeter Measurement Examples. This image illustrates the display during Frequency, Duty Cycle, Diode Test, and Continuity measurements, demonstrating the device's various multimeter functions.

5.2 Àwọn Iṣẹ́ Oscilloscope

The KKM828 features a convenient one-button oscilloscope for waveform analysis.

  1. Rotate the function dial to the 'Graphical' (oscilloscope) mode.
  2. Connect the test leads to the circuit where you wish to observe the waveform.
  3. The device will automatically display the waveform. Use the secondary display at the bottom to view parameters such as Peak-to-Peak voltage (VP-P), average value, RMS value, frequency, time base, and amplitude.
  4. Measurement modes include 'Normal' and 'Automatic'. The device can quickly and accurately measure and display waveforms.
KKmoon KKM828 Waveform Display: showing various electrical waveforms on the oscilloscope screen

Figure 3: Oscilloscope Waveform Display. This image shows examples of different electrical waveforms (sine, square, pulse, complex) as displayed on the KKM828's oscilloscope screen, along with key measurement parameters.

5.3 Data Ibi ati ÌRÁNTÍ

The KKM828 can store up to 100 sets of measurement data and 10 waveforms for later review.

  • Specific instructions for saving and recalling data are typically accessed via the function buttons (e.g., 'S' for Save, 'R' for Recall) in relevant measurement modes. Refer to the on-screen prompts for detailed operation.
  • The device allows for simultaneous display of historical records and real-time data for easy comparison and analysis.

6. Itọju

6.1 Ninu

To clean the device, wipe the casing pẹlu ipolowoamp cloth and a mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any circuits before cleaning. Do not allow moisture to enter the device.

6.2 Batiri Rirọpo

When the low battery indicator appears on the display, replace the three AA batteries as described in the "Battery Installation" section (4.1). Always use fresh batteries of the same type.

6.3 Ibi ipamọ

When not in use for extended periods, remove the batteries to prevent leakage. Store the device in a cool, dry place within the specified storage environment: -10°C to 60°C, with relative humidity less than 90% RH.

7. Laasigbotitusita

This section addresses common issues you might encounter with your KKM828 device.

IsoroOwun to le FaOjutu
Ẹrọ naa ko ṣiṣẹ.Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ.Ṣayẹwo polarity batiri ki o rọpo pẹlu awọn batiri AA tuntun.
A kò fi kíkà tàbí "OL" (Overload) hàn.Incorrect range selected, open circuit, or input exceeds maximum limit.Select appropriate range, check test lead connections, ensure circuit is closed. Verify input does not exceed specifications.
Awọn wiwọn ti ko pe.Low battery, incorrect connection, or environmental factors.Replace batteries, re-check test lead connections, ensure operating environment is within specified range.
Oscilloscope waveform is unstable or absent.Poor connection, signal too weak/strong, or incorrect mode.Ensure secure test lead connection. Adjust amplitude or time base if available (though KKM828 is mostly auto-ranging). Verify signal source.
Device beeps continuously.Iwọn titẹ siitage exceeds 24V (safety warning).Immediately disconnect the device from the circuit and verify the voltage level. Do not proceed if voltage ga ju.

8. Awọn pato

The following table details the technical specifications of the KKmoon KKM828.

ParamitaIye
AwoṣeKKM828
Ifihan2.4-inch 320 x 240 LCM Color Screen
Input Resistance10 MΩ
Batiri Iru3 x AA batiri (ko si)
Agbara agbaraIsunmọ. 80 mA
Operating Time (low brightness)Isunmọ. wakati meji 5
Ibi ipamọ data100 data sets / 10 waveforms
Ayika ti nṣiṣẹ0 ~ 40 °C, <75% RH
Ibi ipamọ Ayika-10 ~ 60 °C, <90% RH
Bandwidth (ACV)1 MHz
Bandwidth (ACA)5 kHz
Max. Real-time SampOṣuwọn ling2.5 Ms
Multimeter Range (DC Voltage)400mV / 4V / 40V / 400V / 1000V (Accuracy: 0.75% rdg + 10dgt)
Multimeter Range (AC Voltage)400mV / 4V / 40V / 400V / 750V (Accuracy: 1.0% rdg + 10dgt)
Multimeter Range (DC Current)40mA / 400mA / 4A / 10A (Accuracy: 1.2% rdg + 10dgt)
Multimeter Range (AC Current)40mA / 400mA / 4A / 10A (Accuracy: 1.5% rdg + 10dgt)
Multimeter Range (Resistance)400.0 Ω ~ 40.00 MΩ (Accuracy: 1.0% rdg + 5dgt)
Multimeter Range (Capacitance)0.1nF ~ 100, 10.00mF (Accuracy: 2.0% rdg + 10dgt)
Multimeter Range (Frequency)5Hz ~ 10MHz (Accuracy: 1.0% rdg + 5dgt)
Multimeter Range (Duty Cycle)0.1 % ~ 99.9 % (Accuracy: 1.0% rdg + 5dgt)
Idanwo DiodeVoltage approx. 5V, Test current approx. 1.5mA
Igbeyewo IlọsiwajuÀwọn ìró Buzzer tí resistance bá < 50Ω
Awọn pato fiusi500mA / 250V, 10A / 250V
Awọn iwọn160 x 83 x 32 mm
Iwọn195 g

© 2023 KKmoon. All rights reserved.