CEM DT-3398B

CEM DT-3398B True RMS AC/DC Clamp Afowoyi olumulo Mita

Model: DT-3398B

1. Ifihan ati Loriview

The CEM DT-3398B Series Professional True RMS Clamp Meter is designed to provide accurate AC and AC/DC current and voltage readings, irrespective of waveform distortions. This instrument is suitable for a wide range of industrial and commercial applications, particularly where non-linear loads may affect current or voltage igbi.

Awọn ẹya pataki pẹlu:

  • AC/DC 2000A Current measurement with a 2-inch (52mm) jaw opening.
  • 6000 counts LCD display for clear readings.
  • True RMS measurements for accurate readings on non-sinusoidal waveforms.
  • Idiwọn Voltage Range: 1000V AC/DC.
  • Measuring Resistance Range: 60MΩ.
  • Measuring Capacitance Range: 10mF.
  • NVC (Non-Contact Voltage) Detection.
  • Built-in Flashlight for illuminated work areas.
  • Bluetooth connectivity for data transmission.
  • Electronic overload protection: CAT IV 1000V.
CEM DT-3398B Clamp Iwaju mita view

olusin 1: Iwaju view of the CEM DT-3398B Clamp Meter, showing the display, rotary dial, and function buttons.

2. Alaye Aabo

Read and understand all safety information before operating this meter. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • CAT IV 1000V Rating: This meter is rated for CAT IV 1000V, indicating its suitability for measurements at the source of the low-voltage fifi sori ẹrọ, gẹgẹ bi awọn mita ina ati awọn ohun elo aabo akọkọ.
  • Ewu Itanna: Always assume that any circuit is live until proven otherwise. Do not touch exposed conductors or circuit components.
  • Lilo daradara: Use the meter only as specified in this manual. Do not exceed the maximum input limits for any function.
  • Ayewo: Kí o tó lo gbogbo ìgbà, ṣe àyẹ̀wò mita náà, dán àwọn ìtọ́sọ́nà wò, àti àwọn ohun èlò míìrán fún ìbàjẹ́ èyíkéyìí. Má ṣe lò ó bí ó bá bàjẹ́.
  • Rirọpo Batiri: Ensure the meter is disconnected from all circuits and powered off before opening the battery compartment.
  • Awọn ipo Ayika: Do not operate the meter in explosive atmospheres or in wet conditions.
  • Ohun elo Idaabobo Ti ara ẹni (PPE): Always wear appropriate PPE, such as safety glasses and insulated gloves, when working with electrical circuits.

3. Awọn ẹya Ọja

The DT-3398B clamp meter offers a comprehensive set of features for professional electrical measurements:

  • Iwọn RMS otitọ: Ó ń pèsè àwọn ìkà tó péye fún àwọn ìgbì AC sinusoidal àti àwọn ìgbì AC tí kì í ṣe sinusoidal.
  • Ṣíṣí Àgbọ̀n Ńlá: 2-inch (52mm) jaw opening accommodates large conductors.
  • Agbara lọwọlọwọ giga: Measures up to 2000A AC/DC current.
  • Voltage Iwọn: Measures up to 1000V AC/DC voltage.
  • Resistance and Capacitance: Includes functions for measuring resistance up to 60MΩ and capacitance up to 10mF.
  • Continuity Buzzer & Diode Check: For quick circuit testing.
  • Data Hold & Peak Hold: Allows freezing of displayed readings and capturing peak values.
  • Ina filaṣi ati ina ẹhin: Enhances visibility in dimly lit environments.
  • MAX/MIN Function: Records maximum and minimum readings over a measurement period.
  • Iwọn Iṣipopada Inrush: Captures transient current surges during motor startup.
  • DCA Zero Function: For accurate DC current measurements.
  • Ṣíṣàwárí NCV: Non-Olubasọrọ Voltage detection for identifying live wires without physical contact.
  • Agbara Aifọwọyi Paa: Nfi aye batiri pamọ.
  • Bluetooth Data Transmission: Enables remote monitoring and data logging via a mobile application.
CEM DT-3398B Clamp Meter with power lines background, highlighting mobile app connectivity

Figure 2: The DT-3398B Clamp Meter, illustrating its capability for AC/DC TRMS measurement and mobile app integration via Bluetooth.

4. Eto

4.1 Fifi sori batiri

The DT-3398B requires one 9V battery for operation. To install or replace the battery:

  1. Ensure the meter is powered off and disconnected from all circuits.
  2. Wa ideri ibi ipamọ batiri naa ni ẹhin mita naa.
  3. Lo ẹ̀rọ ìdènà láti tú ìdè náà tí ó ń so ìbòrí náà mọ́.
  4. Remove the cover and insert a new 9V battery, observing correct polarity.
  5. Rọpo ideri naa ki o si di skru naa mu.

4.2 Nsopọ Awọn itọsọna Igbeyewo

Fun voltage, resistance, capacitance, and diode measurements, connect the test leads to the input jacks:

  • Fi dudu igbeyewo asiwaju sinu COM (Wọpọ) jack.
  • Fi asiwaju igbeyewo pupa sinu VΩCAPHzTemp jaki.
User holding CEM DT-3398B Clamp Meter with test leads connected

Figure 3: User holding the DT-3398B Clamp Meter, demonstrating proper grip and test lead connection points.

5. Awọn ilana Iṣiṣẹ

This section details the operation of various functions of the DT-3398B clamp mita.

5.1 Àṣàyàn Títan/Pápá àti Iṣẹ́

  • To power on the meter, rotate the central rotary dial from the PAA position to the desired measurement function.
  • To power off, rotate the dial back to the PAA ipo.
  • Mita naa ni ẹya kan Agbara Aifọwọyi Paa function to conserve battery life. It will automatically shut down after a period of inactivity.

5.2 Ìwọ̀n Ìṣàn AC/DC (Cl)amp Ẹnu)

  1. Rotate the dial to the A~ (AC Current) tàbí A= (Ipo DC Current).
  2. Tẹ okunfa bakan lati ṣii clamp bakan.
  3. Encircle a single conductor with the clamp àgbọ̀n. Rí i dájú pé àgbọ̀n náà ti sé pátápátá.
  4. Ka awọn ti isiyi iye lori LCD àpapọ.
  5. Fún ìṣàn DC, lo DCA Zero function (if available via a button) to zero the display before measurement to eliminate residual magnetism effects.

5.3 AC / DC Voltage Idiwon

  1. Rotate the dial to the V~ (Ìdìpọ̀ ACtage) tabi V= (DC Voltage) ipo.
  2. So dudu igbeyewo asiwaju si awọn COM jack ati idanwo pupa si asiwaju VΩCAPHzTemp jaki.
  3. Touch the test probes to the circuit points where voltage ni ki won won.
  4. Ka voltage iye lori ifihan LCD.

5.4 Resistance, Continuity, Diode, and Capacitance Measurement

  1. Rotate the dial to the ΩCAP ipo.
  2. So awọn itọsọna idanwo pọ gẹgẹ bi a ti ṣalaye ni Abala 4.2.
  3. Lo awọn MODE button to cycle through Resistance (Ω), Continuity (buzzer icon), Diode (diode symbol), and Capacitance (CAP) functions.
  4. For resistance, connect probes across the component.
  5. For continuity, a beep indicates a continuous circuit.
  6. For diode test, connect probes across the diode.
  7. For capacitance, connect probes across the capacitor (ensure it is discharged).

5.5 NCV (Ti kii ṣe Olubasọrọ Voltage) Wiwa

  1. Rotate the dial to the NCV ipo.
  2. Move the top of the meter near a conductor or outlet.
  3. The meter will emit an audible beep and/or visual indication (e.g., flashing LED) if AC voltage ti ri.

5.6 Special Functions (HOLD, MAX/MIN, Inrush, Flashlight, Bluetooth)

  • MU: Tẹ awọn DIMU bọ́tìnì láti dì kíkà tó wà lórí ìbòjú náà. Tẹ̀ lẹ́ẹ̀kan síi láti tú u sílẹ̀.
  • O pọju/MIN: In a measurement function, press the MAX/MIN button to enter MAX/MIN recording mode. The meter will display the maximum or minimum value recorded. Press again to cycle.
  • Inrush: This function is typically activated by a dedicated button or a specific dial position. It measures the initial surge current when a device (like a motor) starts up.
  • Imọlẹ ina: Press the flashlight button (if dedicated) or hold a specific function button to activate the built-in flashlight.
  • Bluetooth: Activate Bluetooth on the meter (if a dedicated button exists) and pair with a compatible mobile device running the specified application for data logging and remote viewing. Refer to the mobile application's instructions for detailed usage.
CEM DT-3398B Clamp Meter measuring current on a wire, highlighting features like Peak Hold and Inrush Current

Figure 4: The DT-3398B Clamp Meter in use, demonstrating its ability to measure current and highlighting advanced features such as Peak Hold and Inrush Current measurement.

6. Itọju

6.1 Ninu

Fi ìpolówó nu àpótí mita naaamp Aṣọ àti ọṣẹ ìfọṣọ díẹ̀. Má ṣe lo àwọn ohun ìfọṣọ tàbí àwọn ohun tí ó ń yọ́ omi. Rí i dájú pé mita náà gbẹ pátápátá kí o tó lò ó.

6.2 Batiri Rirọpo

Refer to Section 4.1 for instructions on battery replacement. Replace the battery when the low battery indicator appears on the display to ensure accurate measurements.

6.3 Idiwọn

Periodic calibration by qualified personnel is recommended to ensure the meter maintains its accuracy over time. Contact CEM customer support for calibration services.

7. Laasigbotitusita

Isoro Owun to le Fa Ojutu
Mita ko ni agbara lori. Batiri ti ku tabi ti ko tọ. Rọpo batiri 9V, ki o rii daju pe o pe polarity.
Awọn kika ti ko pe. Low battery, incorrect function selected, damaged test leads, external interference. Replace battery, verify function, check test leads for damage, move away from strong electromagnetic fields.
"OL" or "OVER" displayed. Measurement exceeds the meter's range. Select a higher range if available, or ensure the measured value is within the meter's specifications.
No NCV detection. Ko si AC voltage present, or meter not close enough to the source. Verify the presence of AC voltage with another method, ensure the meter's NCV sensor is close to the conductor.
Awọn oran asopọ Bluetooth. Bluetooth not enabled on meter or mobile device, app issues, out of range. Ensure Bluetooth is active on both devices, restart app, move closer to the meter.

8. Awọn pato

The following table outlines the key technical specifications for the CEM DT-3398B Clamp Mita:

Išẹ Iwọn giga Ipilẹ Yiye O pọju. Ipinnu
AC Lọwọlọwọ 2000 A ± (2.5%+5d) 1A
DC Lọwọlọwọ 2000 A ± (2.5%+5d) 1A
AC Voltage 1000V ± (0.8%+2d) 0.1mV
DC Voltage 1000V ± (1.0%+4d) 0.1mV
Atako 60MΩ ± (1.0%+5d) 0.1Ω
Agbara 10mF ± (3.0%+5d) 0.01nF
Electronic Frequency 100 kHz ± (1.2%+3d) 0.01kHz
Iwọn otutu 1000°C/1832°F ± (3.0%+5d) 1°C/°F
Lapapọ ti irẹpọ iparun 99.9% 0.1% ± (3%+10d)
Ti irẹpọ wiwọn iparun 99.9% 0.1% ± (5%+10d)
Agbara Nṣiṣẹ 999.9KW A error x Vreading + Verror x Areading *
Agbara ifosiwewe 1.0 ~ 0.0 ~ 1.0 ± (3%+1d) *
Ayẹwo itesiwaju Buzzer sounds at 50Ω *
Idanwo diode Test current <0.5mA Max 3V *

Awọn Ni pato:

  • Ifihan: 6000 awọn iṣiro LCD
  • Ibẹrẹ Ẹkan: 2 inches (52mm)
  • Ibi ti ina elekitiriki ti nwa: 9V batiri
  • Awọn iwọn (LxWxH): 308mm x 97mm x 47mm
  • Ìwúwo: 732g
  • Iwọn Aabo: Nran IV 1000V
  • Awọn iwe-ẹri: CE, ISO 9001, RoHS
  • Awọn ẹya ara ẹrọ: Test leads, temperature probe (for 3398B/3398W), gift box with carrying case. (Note: 9V battery is required and typically included, contradicting some accessory lists.)
Detailed specifications table for CEM DT-3398B Clamp Mita

Figure 5: Detailed technical specifications for the DT-3398B Clamp Meter, including measurement ranges, accuracy, and resolution.

9. Atilẹyin ọja ati Support

The manufacturer provides a 2-year availability for spare parts. For warranty claims, technical support, or service inquiries, please contact your local distributor or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.