1. Ifihan
This manual provides essential information for the safe and efficient operation of your Tbest AT2-1500X Variable Frequency Drive (VFD) speed controller. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper use and prevent potential hazards.
The Tbest AT2-1500X VFD is designed for controlling the speed of single-phase AC motors up to 1.5 kW. It features a unique control method for high torque, precision, and a wide speed regulation range. Its robust design offers good anti-trip performance and adaptability to various environmental conditions, including power fluctuations, temperature, humidity, and dust interference. The VFD incorporates optimized PWM control technology and electromagnetic compatibility for low noise and reduced electromagnetic interference.
2. Awọn iṣọra aabo
IKILO: Failure to follow these safety instructions may result in death, severe injury, or serious damage to the inverter.
- Always ensure the power supply is disconnected before performing any wiring or maintenance on the VFD.
- Do not touch the VFD terminals when power is applied, as this can cause severe damage to the inverter.
- Do not install the VFD in environments with flammable materials to avoid fire hazards.
- The ground terminal of the inverter must be properly and securely grounded.
- Avoid installing the VFD in environments with explosive gases to prevent explosion hazards.
- Only qualified personnel should perform internal inspections or repairs of the VFD. Incorrect procedures can lead to damage or injury.

olusin 1: Iwaju view of the VFD showing the control panel and safety warning label.
3. Awọn ẹya Ọja
- Iṣe to gaju: Utilizes a unique control method to achieve high torque, high precision, and a wide speed regulation range.
- Iduroṣinṣin Imudara: Features good anti-trip performance and adaptability to power fluctuations, temperature, humidity, and dust interference.
- Low Noise & EMI: Optimized PWM control technology and electromagnetic compatibility minimize operational noise and electromagnetic interference.
- User-Friendly Wiring: Easy to use and connect with screw terminals for convenient wiring.
- Pipade Ooru Mudara: Designed with a large heat sink to ensure effective heat dissipation and prolonged operational life.
4. Awọn pato
| Paramita | Iye |
|---|---|
| Awoṣe | AT2-1500X |
| Ibiti ohun elo | Gbogbo agbaye |
| Ipele Agbara | Ipele Nikan |
| Ti won won Lọwọlọwọ | 8 A |
| Oṣuwọn Voltage | AC 220 V (Single Phase) |
| Ipese Voltage | Kekere Voltage |
| Suitable Motor Power | 1.5 kW |
| Àlẹmọ | Ko si |
| DC Power Source Type | Lọwọlọwọ Iru |
| Ọna Iṣakoso | V/F Open-Loop Control |
| Adijositabulu o wu Voltage Ọna | PWM Iṣakoso |
| Awọn iwọn (isunmọ.) | 12.5 x 12.5 x 18 cm |
| Product Reference Number | Tbesth8d7koib43 |

olusin 2: Ẹyìn view of the VFD, highlighting cooling and terminal access.

olusin 3: Isalẹ view of the VFD, illustrating the heat sink design for efficient cooling.
5. Eto ati fifi sori
Proper installation is crucial for the safe and reliable operation of the VFD. Ensure all safety precautions are followed before proceeding.
5.1 Iṣagbesori
- Mount the VFD in a clean, dry, and well-ventilated area, away from direct sunlight, excessive heat, moisture, and dust.
- Ensure sufficient clearance around the VFD for proper airflow, especially around the heat sink and cooling fans.
- Avoid mounting on flammable surfaces.
5.2 Onirin
All wiring must be performed by a qualified electrician and in accordance with local electrical codes.
- Power Input (L, N): Connect the single-phase AC 220V power supply to the 'L' and 'N' terminals.
- Ìjáde Mọ́tò (U, V, W): Connect the single-phase AC motor to the 'U', 'V', and 'W' terminals. For single-phase motors, typically two of these terminals are used, or specific wiring instructions for your motor should be followed.
- Ilẹ (GND): Connect the ground terminal to a reliable earth ground. This is critical for safety.
- Awọn ibudo Iṣakoso: The VFD includes additional control terminals for external control signals (e.g., start/stop, speed reference). Refer to the detailed wiring diagram for specific connections.

Nọmba 4: Alaye view of the VFD's screw terminals for electrical connections.

Olusin 5: Pariview of the VFD with a focus on the control panel and wiring interface.
6. Awọn ilana Iṣiṣẹ
The VFD features an intuitive control panel for easy operation.

Figure 6: Control panel of the Tbest AT2-1500X VFD.
6.1 Iṣakoso igbimo Loriview
- Ifihan: Shows operational parameters such as frequency, current, voltage, ati iyara.
- Bọtini DISP: Cycles through different display parameters.
- FWD/REV Buttons: Controls the forward and reverse direction of the motor.
- Bọtini PROG: Enters programming mode to adjust VFD parameters.
- Bọtini FUNC/DATA: Used to select functions or confirm data entry in programming mode.
- Àwọn bọ́tìnì ọfà òkè/ìsàlẹ̀: Adjusts parameter values or navigates through menus.
- Kokoro Rotari: Provides fine adjustment for speed or parameter values.
- Bọ́tìnì SÁRÁ (Àwọ̀ ewé): Bẹrẹ motor.
- Bọ́tìnì DÚRÓ/TÚNṢẸ́ (Pupa): Stops the motor or resets fault conditions.
6.2 Ipilẹ isẹ
- Agbara Tan: Ensure all wiring is correct and secure, then apply power to the VFD. The display will illuminate.
- Ṣeto Igbohunsafẹfẹ/Iyara: Use the Up/Down arrow buttons or the rotary knob to set the desired output frequency (and thus motor speed). The display will show the current frequency.
- Ibẹrẹ Motor: Tẹ awọn RUN button to start the motor. The VFD will accelerate the motor to the set frequency.
- Yi Itọsọna pada: If configured, use the FWD/REV buttons to change the motor's rotation direction.
- Mọto Duro: Tẹ awọn Duro/Tunto button to stop the motor. The VFD will decelerate the motor to a stop.
- Atunse paramita: For advanced settings, press the PROG button to enter programming mode. Use the arrow buttons and FUNC/DATA button to navigate and modify parameters. Refer to the full programming manual (if available) for detailed parameter descriptions.
7. Itọju
Itọju deede ṣe idaniloju igbesi aye gigun ati iṣẹ aipe ti VFD rẹ.
- Ninu: Periodically clean the VFD's exterior, especially the ventilation openings and heat sink fins, to prevent dust accumulation. Use a soft, dry cloth. Do not use liquid cleaners.
- Ayewo Olufẹ: Check the cooling fans for proper operation and ensure they are free from obstructions. Replace noisy or malfunctioning fans.
- Ṣíṣàyẹ̀wò Ibùdó: Annually, inspect all wiring terminals for tightness and signs of corrosion or overheating. Retighten connections as necessary (ensure power is off).
- Awọn ipo Ayika: Rii daju pe agbegbe iṣẹ wa laarin iwọn otutu ti a sọ ati awọn sakani ọriniinitutu.
8. Laasigbotitusita
Apá yìí fúnni ní ìtọ́sọ́nà gbogbogbò fún àwọn ọ̀ràn tó wọ́pọ̀. Fún àwọn ìṣòro tó díjú, kan sí ìrànlọ́wọ́ ìmọ̀-ẹ̀rọ.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Mọto ko bẹrẹ | No power, incorrect wiring, STOP/RESET button pressed, parameter error. | Check power supply. Verify wiring connections. Press RUN. Check VFD parameters. |
| Mọ́tò náà ń ṣiṣẹ́ ní iyàrá tí kò tọ́ | Incorrect frequency setting, motor parameters not matched. | Adjust frequency using rotary knob/arrow buttons. Verify motor parameters in VFD settings. |
| VFD ṣe afihan koodu aṣiṣe kan | Overcurrent, overvoltage, undervoltage, overheat, motor overload. | Note the error code. Press STOP/RESET. Consult the full VFD manual for specific error code meanings and solutions. Check motor load and power supply. |
| Ariwo pupọ tabi gbigbọn | Motor imbalance, mechanical issue, VFD parameter mismatch. | Inspect motor and mechanical connections. Review VFD motor parameters. |
9. Atilẹyin ọja ati Support
Specific warranty information for the Tbest AT2-1500X VFD is not provided in this manual. For details regarding warranty coverage, technical support, or service, please contact your retailer or the manufacturer directly. Ensure you have your product model number (AT2-1500X) and any purchase documentation available when seeking support.