1. Ifihan
The HAYEAR HY-800M is a high-performance 4K electronic USB microscope camera designed for various imaging applications. Featuring an 8MP Sony IMX377 CMOS sensor, it delivers clear, high-resolution images and video at 3840x2160 resolution. This digital eyepiece camera is compatible with most biological and stereo microscopes, as well as telescopes, offering versatile connectivity options including USB Type-C for Windows, Mac OS, and OTG-enabled mobile devices. This manual provides essential information for setting up, operating, and maintaining your HY-800M camera.
2. Package Awọn akoonu
Daju pe gbogbo awọn nkan ti a ṣe akojọ rẹ si isalẹ wa ninu package rẹ:
- 1 x HAYEAR HY-800M 8MP Digital Eyepiece Camera
- 1 x Okun USB Iru-C
- 1 x Software Disc (for Windows/Mac OS measurement software)
- 1 x 30mm/30.5mm Adapter
- 1 x 31.7mm Adapter
3. Key Awọn ẹya ara ẹrọ
- Equipped with a Sony 1/2.3-inch IMX377 Color CMOS Image Sensor.
- Video recording at 3840x2160 @ 25fps and 2592x1944 @ 25fps.
- Maximum snapshot resolution of 3840x2160.
- Adjustable parameters: Exposure, Gain, White Balance, and Color.
- USB Type-C 2.0 output with OTG support.
- Includes free measurement software for Windows and Mac OS.
- Standard camera diameter of 23.2mm, compatible with biological microscope eyepieces.
- Includes 30mm/30.5mm adapters for compatibility with most stereo microscope eyepieces.
- Includes a 31.7mm adapter for connection to telescopes or zoom lenses.
- Supports 12-bit/10-bit RAW RGB output format.
4. Eto Itọsọna
4.1 Kamẹra Pariview
Familiarize yourself with the camera's components and specifications.

This image displays the front and back of the HY-800M camera. The front shows the Type-C 2.0 port, model number HY-800M, and specifications: 8MP Eyepiece Camera, 3840x2160 @25fps. The back shows the lens and sensor.
4.2 Iṣagbesori Kamẹra
The HY-800M camera is designed to replace the eyepiece of a microscope or telescope.
- For Biological Microscopes: The camera has a standard diameter of 23.2mm and can be directly inserted into the eyepiece tube of most biological microscopes.
- For Stereo Microscopes: Use the provided 30mm or 30.5mm adapter. Insert the camera into the appropriate adapter, then insert the adapter into the stereo microscope's eyepiece tube.
- For Telescopes/Zoom Lenses: Use the provided 31.7mm adapter. Insert the camera into the adapter, then attach the adapter to your telescope or zoom lens eyepiece holder.

The HY-800M camera is shown connected to a stereo microscope, which is then connected via USB to a laptop. The laptop screen displays a magnified view of a circuit board, demonstrating real-time observation capabilities.

This image illustrates the HY-800M camera attached to a telescope. An adapter is used to secure the camera into the telescope's eyepiece holder, enabling astronomical observation and imaging.

This image presents four diagrams: top-left shows the camera connected to a telescope, top-right shows it connected to a microscope, bottom-left shows it on a microscope stand, and bottom-right illustrates connecting the camera to a cellphone via an OTG adapter and Type-C interface.
4.3 Software fifi sori
The included software disc contains drivers and measurement software for Windows and Mac OS. Follow the on-screen instructions for installation.
- Insert the software disc into your computer's optical drive.
- Run the installer executable (e.g., setup.exe for Windows or .dmg for Mac).
- Tẹle awọn ilana lati pari fifi sori ẹrọ.
- Tun kọmputa rẹ bẹrẹ ti o ba ṣetan.
4.4 Connecting to a Computer/Mobile Device
Use the provided USB Type-C cable to connect the camera to your device.
- Fún PC/Mac: Connect one end of the Type-C cable to the camera and the other end to an available USB port on your computer. The system should automatically detect the camera.
- For OTG-enabled Mobile Devices: Connect the camera to your mobile device using the Type-C cable and an OTG adapter (not included unless specified). Ensure your mobile device supports USB OTG functionality.
5. Awọn ilana Iṣiṣẹ
5.1 Launching the Software
After connecting the camera, launch the installed measurement software on your computer. The software interface will display the live feed from the camera.
5.2 Ṣíṣe àtúnṣe sí àwọn ètò àwòrán
The software allows you to adjust various image parameters for optimal viewing and capture:
- Iṣakoso Ifihan: Adjust automatically or manually to brighten or darken the image.
- Jèrè: Increase or decrease signal amplification.
- Iwontunwonsi Funfun: Set to Auto, Manual, or use One-click White Balance for accurate color representation.
- Brightness, Contrast, Saturation, Hue: Fine-tune these settings to enhance image quality.
- Sharpness, Gamma, Backlight Contrast: Further adjustments for image clarity and detail.
5.3 Yiya Awọn aworan ati Awọn fidio
Refer to the software's user interface for specific buttons and menus to perform the following actions:
- Aworan Sibẹ: Click the 'Snapshot' or 'Capture' button to save a high-resolution image (up to 3840x2160).
- Gbigbasilẹ fidio: Click the 'Record' button to start and stop video recording. The camera supports various resolutions and frame rates as detailed in the specifications.
5.4 Using Measurement Functions
The included software provides measurement tools. Calibrate the software according to your microscope's magnification and then use the tools to measure dimensions, angles, and areas directly on the live or captured images.
6. Itọju
Itọju to dara ati itọju yoo rii daju igbesi aye gigun ati iṣẹ to dara julọ ti kamẹra rẹ.
- Ninu: Lo aṣọ rírọrùn tí ó gbẹ láti nu ara kamera náà. Fún lẹ́ńsì náà, lo aṣọ ìfọmọ́ lẹ́ńsì pàtàkì àti omi ìfọmọ́ lẹ́ńsì. Yẹra fún àwọn ohun èlò ìfọ́ tàbí àwọn kẹ́míkà líle.
- Ibi ipamọ: Store the camera in a cool, dry place away from direct sunlight and extreme temperatures. Use the original packaging or a protective case when not in use.
- Mimu: Handle the camera with care to avoid dropping or impacting it, which could damage internal components.
7. Laasigbotitusita
If you encounter issues with your HY-800M camera, refer to the following common problems and solutions:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| No image displayed in software. | Camera not properly connected; Driver not installed; Software not recognizing camera. | Ensure USB cable is securely connected. Reinstall drivers from the software disc. Try a different USB port. Check software settings to ensure the correct camera is selected. |
| Image is dark or too bright. | Incorrect exposure or lighting. | Adjust the exposure settings in the software (auto/manual). Ensure adequate illumination on your specimen. |
| Colors appear incorrect. | Incorrect white balance setting. | Adjust the white balance in the software (auto/manual/one-click). |
| Sọ́fítíwètì máa ń jábọ́ tàbí kí ó dì. | Software conflict; Outdated drivers; System resource issues. | Update your operating system and graphics drivers. Close other demanding applications. Reinstall the camera software. |
| Camera not recognized by mobile device. | Mobile device does not support OTG; Faulty OTG adapter. | Verify your mobile device's OTG compatibility. Try a different OTG adapter. |
8. Awọn pato
Detailed technical specifications for the HAYEAR HY-800M camera:
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Orukọ awoṣe | HAYEAR 4K Electronic USB Microscope Camera (HY-800M) |
| Sensọ Aworan | Sony 1/2.3-inch Color IMX377 CMOS |
| Iwọn Pixel | 1.55μm(H) × 1.55μm(V) |
| Idahun Spectral | 400nm ~ 700nm |
| Ọna ọlọjẹ | Line-by-line scan, real 8-megapixel sensor, no compression, no interpolation |
| Image Output Format | MJPEG (compressed), YUV422 (compressed) |
| Video Recording (MJPEG) | 3840x2160 @ 25fps; 2592x1944 @ 25fps; 2084x1536 @ 25fps; 1920x1080 @ 25fps; 1280x720 @ 25fps; 800x600 @ 25fps; 640x480 HDR @ 25fps |
| Video Recording (YUV422) | 3840x2160 @ 1fps; 2592x1944 @ 1fps; 2084x1536 @ 1fps; 1920x1080 @ 5fps; 1280x720 @ 10fps; 800x600 @ 15fps; 640x480 HDR @ 15fps |
| Yiyi to Range | 74 dB (linear) / 85 dB (HDR) |
| Ifamọ | 2400 mV/lux-sec |
| Ijade USB | Type-C 2.0, 480Mb/s |
| SNR | 39dB |
| Awọn iwọn otutu ti nṣiṣẹ | -25 ℃ si 70 ℃ |
| Ibi ipamọ otutu | -30 ℃ si 60 ℃ |
| Adijositabulu Parameters | Brightness, Contrast, Saturation, Hue, Sharpness, Gamma, Gain, White Balance, Backlight Contrast, Exposure |
| Ilana UVC | USB Fidio Kilasi (UVC) |
| Iwontunws.funfun | Auto/Manual, One-click White Balance supported |
| Iṣakoso ifihan | Laifọwọyi / Afowoyi |
| Eyepiece Support Diameter | 23.2mm (standard), 30.0mm, 30.5mm, 31.7mm (with adapters) |
| Supported Output Format | 12-bit / 10-bit RAW RGB |
| Ohun elo | Ṣiṣu |
| Àwọ̀ | Dudu |
| Iwọn | 120 giramu |
| Voltage | 5 Volts |
| Awọn ẹrọ ibaramu | Notebook, Personal Computer |
| Orisun agbara | Okun Itanna |
9. Atilẹyin ọja ati Support