1. Ifihan
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your EVURU 2/2 DN25 Stainless Steel Electric Water Valve. This valve is a normally closed, direct-acting solenoid valve designed for controlling the flow of water, gas, or liquid in various applications.
Please read this manual thoroughly before installation and operation to ensure proper function and to prevent damage or injury. Keep this manual for future reference.
2. Alaye Aabo
IKILO: Failure to follow these safety instructions may result in property damage, serious injury, or death.
- Always disconnect power before installing, servicing, or cleaning the valve.
- Rii daju pe voltage supply matches the valve's specified voltage (e.g., AC220V, DC12V). Incorrect voltage can damage the valve or cause electrical hazards.
- Installation should be performed by qualified personnel in accordance with local electrical and plumbing codes.
- Do not exceed the maximum working pressure specified for the valve.
- Ensure the media (water, gas, liquid) and its temperature are within the valve's specified limits.
- Wọ ohun elo aabo ti ara ẹni ti o yẹ (PPE) lakoko fifi sori ẹrọ ati itọju.
- Avoid exposing the valve to corrosive environments or extreme temperatures outside its operating range.
3. Ọja Ipariview
The EVURU 2/2 DN25 SS Electric Water Valve is a robust solenoid valve constructed from Stainless Steel 304, designed for reliable flow control. It features a 1-inch pipe size (DN25) and is available with BSP or NPT threads. The valve operates as normally closed, meaning it remains closed when de-energized and opens when energized.
Figure 1: Assembled EVURU 2/2 DN25 SS Electric Water Valve. This image shows the complete valve unit, including the stainless steel body, the black solenoid coil, and the red electrical wires.
4. Eto ati fifi sori
4.1 Pre-Fifi sọwedowo
- Verify that the valve specifications (voltage, pressure, media, temperature) match your application requirements.
- Inspect the valve for any visible damage from shipping.
- Ensure the piping system is clean and free of debris that could obstruct valve operation.
4.2 fifi sori ẹrọ
- Turn off the main power supply and shut off the fluid flow to the installation area.
- Identify the inlet and outlet ports on the valve body. Flow direction is typically indicated by an arrow on the valve body.
- Apply appropriate thread sealant (e.g., PTFE tape or pipe dope) to the pipe threads.
- Thread the valve onto the pipes, ensuring a tight, leak-free connection. Do not overtighten.
- Mount the valve in a position that allows for easy access for maintenance and inspection. The solenoid coil should ideally be in an upright position to prevent accumulation of debris and ensure proper operation.
4.3 Itanna Asopọ
- Rii daju pe ipese agbara ti ge asopọ.
- Connect the valve's electrical wires to the appropriate power source. Refer to the voltage specified on the solenoid coil.
- Rii daju pe gbogbo awọn asopọ itanna wa ni aabo ati pe o ya sọtọ daradara lati ṣe idiwọ awọn iyika kukuru tabi awọn eewu itanna.
- If applicable, connect the ground wire according to local electrical codes.
Figure 2: Disassembled EVURU 2/2 DN25 SS Electric Water Valve components. This image displays the main stainless steel valve body, the separate solenoid coil, and the retaining nut, illustrating how the coil attaches to the valve stem.
5. Awọn ilana Iṣiṣẹ
The EVURU 2/2 DN25 SS Electric Water Valve is a normally closed (N/C) valve, meaning it is closed by default when no power is applied to the solenoid coil.
- Lati ṣii Valve: Apply the specified electrical voltage to the solenoid coil. The coil will energize, lifting the plunger and opening the valve, allowing fluid to flow.
- Lati Tii Valve naa: Disconnect the electrical voltage from the solenoid coil. The coil will de-energize, and the plunger will return to its closed position, stopping the fluid flow.
Ensure that the system pressure and fluid temperature remain within the valve's specified operating limits during operation.
6. Itọju
Regular maintenance helps ensure the longevity and reliable operation of your valve.
- Ayewo Igbakọọkan: Regularly check for any signs of leaks around the valve body and connections. Inspect the electrical wiring for damage or loose connections.
- Ninu: If the valve is operating in an environment with particulate matter, periodic cleaning of the internal components may be necessary. Always disconnect power and depressurize the system before disassembling the valve.
- Iyipada edidi: Over time, the EPDM seals may wear out. If leaks occur or the valve fails to seal properly, the seals may need to be replaced. Refer to Figure 2 for component identification.
- Ayewo Okun: Ensure the solenoid coil is free from excessive heat, moisture, or physical damage.
Note: For complex repairs or internal component replacement, it is recommended to consult a qualified technician or the manufacturer.
7. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Valve does not open when energized. |
|
|
| Valve does not close when de-energized. |
|
|
| Leakage from valve body or connections. |
|
|
| Gbigbona ti o gbona ju. |
|
|
8. Awọn pato
| Awoṣe | 2W-25B EPDM |
| Iwọn paipu | 1 inch (DN25) |
| Opo Iru | BSP, NPT |
| Media | Water, Gas, Liquid |
| Iru | Normally Closed (N/C), Direct Acting |
| Working Pressure (Water, Air) | 0-10 igi |
| Working Pressure (Oil) | 0-7 igi |
| Voltage Aw | AC240V, AC220V, AC120V, AC110V, AC24V, DC24V, DC12V (±10% tolerance) |
| Ohun elo | Irin alagbara 304 |
| Ohun elo Igbẹhin | EPDM |
| Medium Temperature (EPDM) | -5 si 120°C (23 si 248°F) |
| Iwọn Nkan | 1 Grams (Note: This value seems unusually low and may be a placeholder. Refer to actual product for accurate weight.) |
9. atilẹyin ọja Information
Specific warranty details for the EVURU 2/2 DN25 SS Electric Water Valve are not provided in this manual. For information regarding product warranty, please refer to the purchase documentation, contact your retailer, or visit the official EVURU webojula.
10. Onibara Support
If you encounter any issues or have questions not covered in this manual, please contact your product supplier or the manufacturer's customer support. When contacting support, please have your product model number (2W-25B EPDM) and purchase details readily available.