1. Alaye Aabo pataki
Please read this instruction manual carefully before operating the ProfiCare PC-HL 3116 wall-mounted ceramic fan heater. Keep this manual for future reference.
- Ensure the appliance is connected to a power supply that matches the specifications (220-240V, 50-60Hz).
- Do not cover the heater. Maintain adequate clearance from walls, furniture, and curtains to prevent overheating.
- This appliance is equipped with overheat protection. If the heater becomes too hot, it will automatically switch off.
- Do not use this heater in the immediate vicinity of a bath, shower, or swimming pool. It has IP24 splash protection, but direct water exposure should be avoided.
- Ọja yii dara fun awọn yara ti o ni idalẹnu daradara nikan tabi fun lilo lẹẹkọọkan.
- Pa awọn ọmọde ati awọn ohun ọsin kuro ninu ohun elo lakoko iṣẹ.
- Always unplug the heater before cleaning or maintenance.
2. Package Awọn akoonu
Jẹrisi pe gbogbo awọn ohun kan wa ninu package:
- ProfiCare PC-HL 3116 Wall-Mounted Ceramic Fan Heater Unit
- Iṣakoso latọna jijin (batiri pẹlu)
- Mounting Material (screws and wall plugs)
- Ilana itọnisọna
3. Ọja Ipariview
The ProfiCare PC-HL 3116 is a wall-mounted ceramic fan heater designed for efficient and comfortable heating of rooms up to 60 m².

Nọmba 3.1: Iwaju view of the ProfiCare PC-HL 3116 heater with heat emission indicated.

Nọmba 3.2: Close-up of the heater's LED display showing temperature and mode indicators.
3.1 Main Awọn ẹya ara ẹrọ
- Ohun elo Igbóná PTC seramiki: Provides fast and efficient heat.
- Ifihan LED: Shows current temperature and operational status.
- Isakoṣo latọna jijin: Isakoṣo latọna jijin iṣẹ-kikun fun iṣẹ irọrun.
- Ṣii Wiwa Window: Automatically switches off when a sudden temperature drop is detected.
- Iṣẹ Swing: Distributes air optimally throughout the room.
- Adijositabulu otutu: O le wa ni iwọn otutu lati 18°C si 45°C.
- Two Heating Levels: 1000W and 2000W.
- Aago 8-wakati: For scheduled operation.
- 6 Time Programs: Customizable heating schedules.
- Ipo Aifọwọyi: Adjusts heating level based on set temperature.
- Idaabobo igbona ju: Enhances safety during operation.
- IP24 Splash Protection: Suitable for use in bathrooms (zone 3).
3.2 Iṣakoso latọna jijin
The included remote control allows for convenient adjustment of all heater functions.

Nọmba 3.3: Remote control with various function buttons.
The remote control includes buttons for power, temperature adjustment, timer, heating level selection, fan function, time programs, and swing function. A battery is pre-installed.
4. fifi sori
The PC-HL 3116 heater is designed for wall mounting. Ensure the chosen location is suitable and allows for proper air circulation.
4.1 Yiyan ipo kan
- Select a wall location that is clear of obstructions and flammable materials.
- Ensure there is sufficient space around the heater for optimal heat distribution and safety.
- The power cable length is 1.5 meters, so choose a location within reach of a suitable power outlet.
4.2 iṣagbesori Awọn ilana
Use the provided mounting material (screws and wall plugs) for secure installation.
- Mark the desired mounting points on the wall according to the heater's dimensions. Refer to Figure 4.1 for approximate dimensions.
- Lilu ihò ni samisi ojuami.
- Fi awọn pilogi odi sinu awọn iho ti a ti gbẹ iho.
- Secure the heater to the wall using the screws. Ensure it is firmly attached.
- Pulọọgi okun agbara sinu itanna ti ilẹ.

Nọmba 4.1: Heater dimensions and illustration of mounting material.
5. Isẹ
Operate the ProfiCare PC-HL 3116 using the control panel on the unit or the remote control.
5.1 Agbara Tan / Pa
Tẹ awọn Agbara button on the remote control or the unit to turn the heater on or off.
5.2 Ṣiṣeto iwọn otutu
Lo awọn Temperature Up (+) ati Temperature Down (-) buttons on the remote control to set the desired room temperature between 18°C and 45°C. The LED display will show the set temperature.
5.3 Awọn ipele alapapo
Select between two heating levels:
- Kekere (1000W): For moderate heating or maintaining temperature.
- Giga (2000W): Fun itutu yara naa ni kiakia.
Use the dedicated button on the remote control to cycle through the heating levels.
5.4 Fan Function
The heater can operate in fan-only mode without heat, providing air circulation. Activate this function using the remote control.
5.5 Timer and Time Programs
- Aago 8-wakati: Set the heater to operate for a specific duration up to 8 hours.
- 6 Time Programs: Configure custom heating schedules for different times of the day or week. Refer to the remote control section for specific button functions.
5.6 Swing Function
Mu ṣiṣẹ naa Swing function to enable the internal louvers to oscillate, distributing warm air more evenly across the room.

Nọmba 5.1: Illustration of optimal air distribution via the swing function.
5.7 Aifọwọyi Ipo
In Automatic Mode, the heater will automatically switch between heating levels (1000W/2000W) or turn off/on to maintain the set temperature efficiently.
5.8 Ṣii Window erin
The heater features an intelligent open window detection system. If a sudden drop in room temperature is detected (indicating an open window), the heater will automatically switch off to conserve energy. It will resume operation once the window is closed and the temperature stabilizes, or can be manually restarted.

Nọmba 5.2: Heater demonstrating automatic shut-off with open window detection.
6. Itọju
Fífọmọ́ déédé àti ìpamọ́ tó péye yóò jẹ́ kí ẹ̀rọ ìgbóná rẹ pẹ́ títí, yóò sì ṣiṣẹ́ dáadáa.
6.1 Ninu
- Yọọ ẹrọ ti ngbona nigbagbogbo lati iṣan agbara ati gba laaye lati tutu patapata ṣaaju ṣiṣe mimọ.
- Mu ese ita gbangba pẹlu asọ, damp asọ. Ma ṣe lo abrasive ose tabi epo.
- Ensure no water enters the interior of the appliance.
- Periodically clean the air inlet and outlet grilles with a soft brush or vacuum cleaner to remove dust accumulation.
6.2 Ibi ipamọ
If the heater will not be used for an extended period, unplug it and store it in a cool, dry place, preferably in its original packaging.
7. Laasigbotitusita
If you encounter issues with your ProfiCare PC-HL 3116 heater, refer to the following common problems and solutions:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Alagbona ko ni tan-an. | Ko si ipese agbara. A ko tẹ bọtini agbara. | Check if the power cable is securely plugged in. Rii daju pe iṣan ogiri jẹ iṣẹ-ṣiṣe. Tẹ bọtini agbara lori ẹrọ tabi isakoṣo latọna jijin. |
| Ko si igbejade ooru. | Heating level not selected. Open window detection activated. Idaabobo igbona ti mu ṣiṣẹ. | Select a heating level (1000W or 2000W). Close any open windows; the heater should resume or can be restarted. Unplug the heater, let it cool down for 30 minutes, then plug it back in. Ensure proper ventilation. |
| Swing function not working. | Swing function not activated. | Press the swing button on the remote control. |
| Isakoṣo latọna jijin ko ṣiṣẹ. | Batiri ti dinku. Idilọwọ laarin isakoṣo latọna jijin ati igbona. | Replace the battery (12V). Ensure a clear line of sight to the heater's receiver. |
Ti iṣoro naa ba wa lẹhin igbiyanju awọn solusan wọnyi, jọwọ kan si atilẹyin alabara.
8. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Brand | ProfiCare |
| Nọmba awoṣe | PC-HL 3116 |
| Agbara | 2000 Wattis |
| Voltage | 230 Volts |
| Iwọn (D x W x H) | 14.5 x 60 x 23.2 cm |
| Iwọn | 2.35 kilo |
| Ohun elo | Plastic, PTC Ceramic |
| Alapapo Ọna | PTC Seramiki Alapapo Ano |
| Niyanju Yara Iwon | Ti o to 60 m² |
| Iwọn otutu | 18°C si 45°C |
| Alapapo Awọn ipele | 2 (1000W / 2000W) |
| Aago | wakati meji 8 |
| Awọn eto akoko | 6 |
| Pataki Awọn ẹya ara ẹrọ | Open Window Detection, Overheat Protection, LED Display, Swing Function, Remote Control, IP24 Splash Protection |
| USB Ipari | 1.5 mita |
| Ilu isenbale | China |
9. Atilẹyin ọja ati Support
The manufacturer provides a 2-year availability for spare parts for this product. For warranty claims, technical support, or service inquiries, please refer to the contact information provided with your purchase documentation or visit the official ProfiCare webojula.