Vabiooth RM

Vabiooth Trinocular Compound Microscope User Manual

Awoṣe: RM (Darkfield Blood Model)

Brand: Vabiooth

1. Ifihan

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your Vabiooth Trinocular Compound Microscope (Darkfield Blood Model). Please read this manual thoroughly before using the microscope to ensure proper function and longevity of the device. Keep this manual for future reference.

2. Alaye Aabo

  • Aabo Itanna: Ensure the microscope is connected to a grounded power outlet with the correct voltage (110V AC). Do not operate with wet hands. Disconnect power before cleaning or maintenance.
  • Mimu: Handle the microscope with care. Avoid sudden impacts or vibrations. Always carry the microscope by its main body, not by the head or stage.
  • Optical Components: Do not touch optical surfaces with bare hands. Use a soft, lint-free cloth for cleaning.
  • Ayika: Use the microscope in a clean, dry, and dust-free environment. Avoid direct sunlight and extreme temperatures.
  • Awọn ọmọde: This device is not a toy. Adult supervision is required when children are operating the microscope.

3. Package Awọn akoonu

Your Vabiooth Trinocular Compound Microscope package includes the following items:

  • Vabiooth Trinocular Compound Microscope body
  • WF10X, WF16X, WF25X glass eyepieces
  • 4 Achromatic objective lenses (4x, 10x, 40x(s), 100x(Spring Oil))
  • 7-inch LCD monitor with E-eyepiece (5MP)
  • Apoti aluminiomu
  • Microscope slides and cover glass
  • Adaparọ agbara
  • Ideri eruku
  • Asọ mimọ
  • Other accessories (e.g., immersion oil, tools)
Vabiooth Trinocular Compound Microscope and accessories in a carry case

Nọmba 3.1: The Vabiooth Trinocular Compound Microscope with its various eyepieces, slides, and aluminum carry case.

4. Ọja irinše

Mọ ara rẹ pẹlu awọn ẹya pataki ti maikirosikopu rẹ:

  • Observation Head: Trinocular head with adjustable interpupillary distance and diopter.
  • Awọn oju oju: WF10X, WF16X, WF25X for various magnifications.
  • Awọn lẹnsi Idi: Revolving nosepiece with 4x, 10x, 40x(s), 100x(Spring Oil) achromatic objectives.
  • Ẹ̀rọ Stage: Double-layer mechanical stage with X-Y axis movement for precise specimen manipulation.
  • Focus Knobs: Coarse and fine focus adjustment knobs.
  • Eto itanna: LED illumination with adjustable intensity.
  • Condenser: NA 1.25 Abbe condenser with iris diaphragm for brightfield and darkfield observation.
  • Atẹle LCD: 7-inch LCD display for direct viewing ati pinpin.
Close-up of the Vabiooth Trinocular Compound Microscope showing the 7-inch LCD display, rotatable head, and ocular tubes.

Nọmba 4.1: Key features of the microscope head and LCD display.

5. Eto

  1. Ṣii silẹ: Carefully remove all components from the aluminum carry case.
  2. Ibi: Place the microscope body on a stable, level surface away from direct sunlight and heat sources.
  3. Fifi sori ẹrọ oju: Insert the desired eyepieces (e.g., WF10X) into the ocular tubes of the trinocular head.
  4. LCD Monitor Attachment: Attach the 7-inch LCD monitor to the dedicated port on the trinocular head. Ensure it is securely fastened.
  5. Asopọ agbara: Connect the power adapter to the microscope and then to a grounded electrical outlet.

Fidio 5.1: Ipariview of the Vabiooth Darkfield & Brightfield Trinocular Compound Microscope, demonstrating its components and basic setup. This video highlights the microscope's dual observation capabilities and trinocular design.

6. Awọn ilana Iṣiṣẹ

6.1 Power and Illumination

  • Turn on the microscope using the power switch located on the base.
  • Adjust the LED illumination intensity using the dimming handwheel for optimal viewing.
Close-up of the microscope base showing the LED illumination and adjustment knob.

Nọmba 6.1: Adjusting the variable LED intensity transmitted illumination.

6.2 Specimen Placement

  • Place a prepared slide onto the double-layer mechanical stage.
  • Lo awọn stage manipulation knobs to center the specimen under the objective lens.
Close-up of the mechanical stage with adjustment handle for precise specimen movement.

Nọmba 6.2: Awọn ẹrọ stage with adjustment handle allows for full movement of your sample for scanning or centering.

6.3 Idojukọ

  • Use the coarse focus knob for large adjustments to bring the specimen into approximate focus.
  • Use the fine focus knob for precise adjustments to achieve a sharp image.
Close-up of the coaxial coarse and fine focus knobs on the microscope body.

Nọmba 6.3: Coaxial coarse and fine focus knobs for ergonomic and precise focusing.

6.4 Iṣogo

  • Rotate the revolving nosepiece to select the desired objective lens (4x, 10x, 40x, 100x).
  • The total magnification is the product of the eyepiece magnification and the objective lens magnification. For example, a WF10X eyepiece with a 100x objective provides 1000x magnification.
Close-up of the objective lenses on the revolving nosepiece, indicating 2500x magnification with 100x oil immersion objective.

Nọmba 6.4: The microscope offers eight levels of magnification from 40X to 2500X using 4X, 10X, 40X, and 100X objectives.

6.5 Interpupillary Distance and Diopter Adjustment

  • Adjust the distance between the two eyepieces to match your interpupillary distance for comfortable binocular viewing.
  • If one eye has a different focus requirement, adjust the diopter ring on the eyepiece until both eyes see a sharp image.

6.6 Darkfield and Brightfield Observation

  • The NA 1.25 Abbe condenser with iris diaphragm supports both brightfield and darkfield observation.
  • To switch between modes, adjust the condenser. Note that this darkfield microscope is specifically designed for researching live blood.
Comparison image showing a specimen under brightfield and darkfield illumination.

Nọmba 6.5: Adjusting the condenser allows switching between brightfield and darkfield observation modes.

Fidio 6.1: This video demonstrates the Blood Darkfield Brightfield Trinocular Compound Microscope in action, showcasing its capabilities for observing blood samples under different illumination techniques.

6.7 LCD Monitor and E-Eyepiece Usage

  • The 7-inch LCD display provides a direct view of the specimen, allowing for easier observation and sharing without eye strain.
  • The 5MP E-eyepiece can be connected to a computer via USB to display images on a larger screen or capture photos/videos.

6.8 Constant Temperature Function

  • Maikirosikopu stage features a constant temperature function, allowing adjustment of the stage's temperature from 0-50 degrees Celsius. This is useful for observing temperature-sensitive specimens.

7. Itọju

  • Awọn lẹnsi mimọ: Use a soft, lint-free cloth and lens cleaning solution to gently wipe objective lenses and eyepieces. Avoid excessive pressure.
  • Ara Isọmọ: Nu ara microscope naa pẹlu asọ, damp asọ. Maṣe lo awọn kemikali lile.
  • Ibi ipamọ: When not in use, cover the microscope with the provided dust cover and store it in the aluminum carry case in a dry, dust-free place.
  • Oil Immersion: After using the 100x oil immersion objective, clean the oil from the lens immediately using lens paper and cleaning solution.

8. Laasigbotitusita

IsoroOwun to le FaOjutu
Ko si itannaPower not connected; bulb faulty; intensity knob set to minimum.Check power connection; replace bulb (if applicable); adjust intensity knob.
Image unclear/blurryIncorrect focus; dirty lens; objective not fully engaged.Adjust coarse/fine focus; clean lenses; rotate objective until it clicks into place.
Dark field image not clearCondenser not correctly adjusted for darkfield.Ensure condenser is set to darkfield mode and properly centered.
LCD monitor no displayMonitor not powered; E-eyepiece not connected properly.Check monitor power and cable connections.

9. Awọn pato

Ẹya ara ẹrọSipesifikesonu
BrandVabiooth
Orukọ awoṣeRM
Ibiti Imudara40X-2500X
Awọn oju ojuWF10X, WF16X, WF25X
Awọn lẹnsi Idi4x, 10x, 40x(s), 100x(Spring Oil) Achromatic
CondenserNA 1.25 Abbe with Iris Diaphragm (Brightfield & Darkfield)
ItannaLED (Adjustable Intensity)
Atẹle LCD7-inch, 5MP E-Eyepiece
StageDouble-layer Mechanical Stage (1.0mm divisions)
IdojukọCoaxial Coarse & Fine Adjustment
Išẹ otutuAdjustable 0-50°C (on stage)
Orisun agbara110 Volt (AC)
Iwọn Nkan19.03 iwon
Ohun eloAluminiomu

10. Atilẹyin ọja ati Onibara Support

The manufacturer's warranty period for this product is 18 osu lati ọjọ ti o ra.

For any questions, technical support, or warranty claims, please contact Vabiooth Customer Care Center:

  • Email & WhatsApp: Vabiooth@outlook.com
  • Foonu: + 86 17306342950
  • Awọn wakati iṣẹ: Monday through Friday (EST 9:00-11:00 or 20:00-24:00), excluding public holidays.
  • Nigbati o ba kan si atilẹyin, jọwọ pese nọmba ibere rẹ.
QR code for WhatsApp support.

Nọmba 10.1: Scan the QR code to quickly reach Vabiooth on WhatsApp.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.