Ọrọ Iṣaaju

This manual provides essential information for the safe and efficient operation of your SHARP Airest R-P Series Air Conditioner, model AY-R40P-W. Please read this manual thoroughly before using the product and keep it for future reference.

SHARP Airest R-P Series Air Conditioner AY-R40P-W

olusin 1: Iwaju view of the SHARP Airest R-P Series Air Conditioner AY-R40P-W indoor unit.

Eto ati fifi sori

This air conditioner is typically sold with standard installation services included. Please follow the steps outlined by the installation provider (XPRICE in this case) for proper setup.

Fifi sori Ilana Sisan

The general flow from purchase to installation is as follows:

Installation Process Flow Chart

Figure 2: Step-by-step guide for air conditioner installation from purchase to completion.

  1. STEP 1: Order on HP (Homepage) - Place your order for the air conditioner.
  2. STEP 2: Reply to Hearing Sheet - After your order, a "Hearing Sheet" will be sent to your registered email address to confirm your home's situation and desired installation date. Please ensure to reply.
  3. STEP 3: Installation Date Guidance/Consultation - Communication regarding the installation date will be made via email.
  4. STEP 4: Product Receipt - The product will be delivered to you before the installation date.
  5. STEP 5: Contact for Visit Time - You will be contacted to confirm the visit time for installation.
  6. STEP 6: Visit & Installation - The installation team will visit your home and complete the setup.

Standard Installation Scope

  • Installation of both indoor and outdoor units.
  • Includes plastic blocks and piping work (up to 4 meters of piping and tape-wrapped finish).
  • Drilling one hole in general wooden or mortar walls is typically free of charge.

Note: Depending on your home's specific conditions, additional charges may apply on-site for non-standard installations.

Potential Additional Installation Costs

Certain installation scenarios may incur additional charges. Example pẹlu:

Additional Outdoor Unit Installation Costs

Olusin 3: Examples of additional costs for outdoor unit installation based on location (e.g., rooftop, wall-mounted, veranda, two-tier placement) and high-altitude work.

Additional Piping Cover Installation Costs

Olusin 4: Examples of additional costs for piping cover work, including new covers, reuse of existing covers, additional straight covers, and ventilation head/corner parts.

Additional Power Supply Related Costs

Olusin 5: Examples of additional costs related to power supply, such as dedicated electrical wiring, outlet replacement, outlet extension, voltage switching, and molding work.

Awọn ilana Iṣiṣẹ

Your SHARP Airest air conditioner is designed for efficient heating and cooling. Refer to the remote control manual (sold separately or included in packaging) for detailed button functions and mode selections.

Isẹ ipilẹ

  • Ipo itutu: Use for cooling your room. The unit has a cooling capacity of 4.0kW (min 0.8kW ~ max 4.4kW) and consumes 1240W (min 180W ~ max 1550W).
  • Ipo alapapo: Use for heating your room. The unit has a heating capacity of 5.0kW (min 0.8kW ~ max 6.4kW) and consumes 1480W (min 150W ~ max 2000W). At an outdoor temperature of 2°C, the heating capacity is 4.8kW.
  • Iṣakoso iwọn otutu: Adjust the desired temperature using the remote control. The unit is designed to maintain the set temperature with high precision (e.g., 26°C setting results in approximately 26°C ±0.3°C room temperature).
  • Itọsọna Afẹfẹ: Adjust the louver direction for optimal comfort. In cooling mode, air is discharged from above, which may make you feel colder than the set temperature if you are directly in the airflow.

Itoju

Regular maintenance ensures optimal performance and longevity of your air conditioner. Always turn off the power supply before performing any maintenance.

Filter Cleaning

  • Clean the air filters regularly (e.g., every two weeks or as needed) to maintain airflow and efficiency.
  • Refer to the detailed instructions in the remote control manual for how to remove and clean the filters.
  • Ensure no protective films or packaging materials are left on the filters or inside the unit after installation or cleaning, as this can impede airflow and performance.

Ita Cleaning

  • Mu ese ita ti inu ati ita ita pẹlu asọ, damp asọ.
  • Do not use harsh detergents, abrasive cleaners, or solvents.

Laasigbotitusita

If you encounter issues with your air conditioner, refer to the following common troubleshooting tips before contacting service.

IsoroOwun to le Fa / Solusan
Weak Airflow or Insufficient Cooling/Heating
  • Clogged Air Filter: Mọ awọn asẹ afẹfẹ.
  • Protective Film on Filter: PATAKI: Check if any protective film or packaging material is still attached to the air filter or inside the unit. Remove any such film. A user reported significantly improved performance after removing a film from the filter.
  • Incorrect Mode Setting: Ensure the unit is set to the correct mode (Cooling/Heating).
  • Eto iwọn otutu: Verify the set temperature is appropriate for the desired room condition.
  • Room Size Mismatch: The unit is rated for 14 tatami mats. If used in a larger space, performance may be reduced. Consider using it in a smaller room (e.g., 8 tatami mats) for optimal performance if your current room is at the upper limit of its capacity.
Ẹka Ko Titan-an
  • Ibi ti ina elekitiriki ti nwa: Check if the power plug is securely inserted and the circuit breaker has not tripped.
  • Awọn batiri Iṣakoso Latọna jijin: Rọpo awọn batiri ni isakoṣo latọna jijin.
Awọn Ariwo Alailẹgbẹ
  • Awọn ẹya alaimuṣinṣin: Ensure all covers and panels are securely closed.
  • Awọn idilọwọ: Check for any foreign objects near the fan or air vents.

If the problem persists after attempting these solutions, please contact the installation partner company or XPRICE support for assistance.

Awọn pato

Detailed technical specifications for the SHARP Airest R-P Series Air Conditioner AY-R40P-W:

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Nọmba awoṣeAY-R40P-W
Applicable Room Size (Approx.)Mainly 14 Tatami Mats
Agbegbe Alapapo11-14 Tatami Mats (18-23 m²)
Agbegbe itutu11-17 Tatami Mats (18-28 m²)
Alapapo Agbara5.0kW (Min 0.8kW ~ Max 6.4kW)
Heating Capacity (Outdoor 2°C)4.8kW
Agbara Itutu4.0kW (Min 0.8kW ~ Max 4.4kW)
Power Consumption (Heating)1480W (Min 150W ~ Max 2000W)
Power Consumption (Cooling)1240W (Min 180W ~ Max 1550W)
Estimated Annual Electricity Bill¥42,400 (Calculated based on 18 hours/day usage during heating/cooling seasons, at ¥27/kWh. Actual cost may vary.)
Ibi ti ina elekitiriki ti nwaSingle-phase 100V 20A
Outlet ShapeIL type
Indoor Unit Dimensions (W×H×D)798 × 278 × 447 mm
Outdoor Unit Dimensions (W×H×D)800 (+pipe cover 65) × 630 × 300 (+leg 46) mm
Ibile Unit iwuwo17 kg
Ita gbangba Unit iwuwo38 kg
O pọju Pipin Gigun15 m
Maximum Piping Height Difference10 m
Used Piping2-bun 3-bun piping (2/3 inch equivalent)

Atilẹyin ọja ati Support

Atilẹyin ọja fifi sori ẹrọ

Ọja yi wa pẹlu kan 3-year installation warranty provided by XPRICE. This warranty covers operational defects caused by installation issues for three years from the date of purchase.

3-Year Installation Warranty

Figure 6: Visual representation of the 3-year installation warranty.

Note: The installation warranty is provided by XPRICE and its installation partner companies. Some remote islands and areas may not be serviceable under this warranty.

Olubasọrọ Support

For any inquiries regarding installation, warranty claims, or product support, please contact XPRICE directly. Refer to the XPRICE Help section for detailed contact information and service areas.

XPRICE Seller Information:

© 2023 SHARP Corporation. Gbogbo ẹ̀tọ́ ni a fipamọ́.

Itọsọna yii wa fun awọn idi alaye nikan. Awọn pato jẹ koko ọrọ si iyipada laisi akiyesi.