Andonstar AD246SM-Plus

Andonstar AD246SM-Plus Digital Microscope User Manual

Model: AD246SM-Plus

1. Ifihan

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your Andonstar AD246SM-Plus Digital Microscope. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage.

2. Package Awọn akoonu

Daju pe gbogbo awọn nkan ti a ṣe akojọ rẹ si isalẹ wa ninu package rẹ:

  • Maikirosikopu x1
  • Metal stand x1
  • Extension Base x1
  • Tool holder x1
  • Soldering Clamp x1
  • Soldering mat x1
  • Lens A x1 (18X-720X)
  • Lens D x1 (1800X-2040X)
  • Lens L x1 (60X-240X)
  • okun USB x1
  • Switch cable x1
  • HDMI okun x1
  • Isakoṣo latọna jijin x1
  • Slide holder x1
  • Slides kit x5
  • Observation box x1
  • Tweezers x1
  • 32G Micro SD card x1
  • Ilana x1
Andonstar AD246SM-Plus Digital Microscope package contents

Image: All components included in the Andonstar AD246SM-Plus Digital Microscope package, laid out for inspection.

3. Awọn ilana iṣeto

3.1 Assembling the Stand and Workstation

  1. Place the main metal stand base on a stable surface.
  2. Attach the extension base components to the main stand base to create a larger workspace. Ensure they are securely interlocked.
  3. Mount the flexible helping hands with clamps onto the designated slots on the extension base. Adjust their position as needed.
  4. Install the tool holder bar onto the main stand's vertical pole.
  5. Place the soldering mat in the center of the extended base.
Assembled Andonstar AD246SM-Plus microscope workstation with helping hands and tool holder

Image: The fully assembled workstation of the Andonstar AD246SM-Plus microscope, showing the extended base, helping hands, and tool holder.

Assembly steps for Andonstar AD246SM-Plus microscope stand and base

Image: A visual guide illustrating the step-by-step assembly process for the microscope stand and its extended base components.

3.2 Attaching the Microscope Unit

  1. Carefully attach the microscope unit to the adjustable holder on the vertical pole of the stand.
  2. Tighten the securing screws to ensure the microscope is firmly in place.
  3. Connect the flexible LED lights to the stand and position them to illuminate the working area.
Andonstar AD246SM-Plus microscope with flexible LED lights attached to the stand

Image: The microscope unit mounted on its stand, with the flexible LED lights positioned for optimal illumination of the observation area.

3.3 Agbara Lori ati Asopọ Ibẹrẹ

  1. Connect the power adapter to the microscope and a power outlet.
  2. Tẹ bọtini agbara lati tan-an maikirosikopu.
  3. Fun tobi viewing, connect the microscope to an external display (monitor or TV) using the provided HDMI cable or to a PC via USB.
Andonstar AD246SM-Plus microscope connected to a large monitor via HDMI

Image: The Andonstar AD246SM-Plus microscope displaying its view on a large external monitor via HDMI connection, illustrating the dual-screen capability.

Video: This video demonstrates the assembly process of the Andonstar AD246SM-Plus digital microscope, including attaching the base, helping hands, and the microscope unit itself. It also shows the microscope in operation with different lenses.

4. Awọn ilana Iṣiṣẹ

4.1 Lens Selection and Usage

The AD246SM-Plus comes with three interchangeable lenses, each designed for specific observation distances and magnification ranges:

  • Lẹ́nsì A (18X-720X): Ideal for observing larger objects such as coins, stamps, circuit boards, and stones. Observation distance: 12mm-320mm.
  • Lens L (60X-240X): Suitable for PCB/SMD soldering and general circuit board observation. Observation distance: 90mm-300mm.
  • Lẹ́nsì D (1800X-2040X): Designed for microscopic slides and very fine details. Observation distance: 4mm-5mm.

To change a lens, gently twist the current lens counter-clockwise to remove it, then align the new lens and twist clockwise until secure.

Andonstar AD246SM-Plus microscope with Lens A, showing a coin magnified

Image: Microscope with Lens A, demonstrating its use for magnifying a coin, suitable for larger objects.

Andonstar AD246SM-Plus microscope with Lens L, showing a circuit board magnified

Image: Microscope with Lens L, showing a magnified view of a circuit board, ideal for soldering tasks.

Andonstar AD246SM-Plus microscope with Lens D, showing a microscopic slide magnified

Image: Microscope with Lens D, displaying a highly magnified view of a microscopic slide, for very fine details.

4.2 Focusing and Magnification Adjustment

Use the focus knob on the microscope body to achieve a clear image. Adjust the distance between the lens and the object by moving the microscope unit up or down on the stand for optimal magnification and clarity.

Andonstar AD246SM-Plus microscope showing focus knob and object distance adjustment

Aworan: Isunmọ view of the microscope's focus knob and the mechanism for adjusting the object distance, crucial for clear magnification.

4.3 LED Lighting and Remote Control

The built-in 8 LED lights provide adjustable brightness and lighting angles. Use the remote control to capture images and record videos without disturbing the microscope, ensuring stable and clear results.

5. Itọju

  • Awọn lẹnsi mimọ: Use a soft, lint-free cloth and lens cleaning solution to clean the lenses. Avoid abrasive materials.
  • Isọsọ gbogboogbo: Nu ara microscope naa ki o si duro pẹlu gbigbẹ tabi die-die damp asọ. Maṣe lo awọn kemikali lile.
  • Ibi ipamọ: Store the microscope in a dry, dust-free environment when not in use.
  • Soldering Mat: The silicone soldering mat is resistant to heat, dirt, and oil. Clean it regularly to maintain its protective properties.

6. Laasigbotitusita

IsoroOwun to le FaOjutu
Ko si aworan loju ibojuPower not connected; Microscope not turned on; HDMI/USB cable loose or faulty.Check power connection; Press power button; Reconnect or replace cables.
Aworan blurryIncorrect focus; Wrong lens for object distance; Object too far/close.Adjust focus knob; Select appropriate lens (A, L, or D); Adjust microscope height.
Yiyi iboju tabi aworan riruLoose cable connection; Power supply issue; Interference.Ensure all cables are securely connected; Try a different power outlet; Minimize electronic interference.
Isakoṣo latọna jijin ko ṣiṣẹBatteries depleted; Obstruction between remote and microscope.Replace remote control batteries; Ensure clear line of sight to the microscope's IR receiver.

7. Awọn pato

  • Awoṣe: AD246SM-Plus (SXWL-246S-M-Plus)
  • Ipinnu fidio: Ultra HD 2880x2160 24fps; Full HD 1920x1080 60fps/30fps; HD 1280x720 120fps
  • Ìfikún: Up to 2000X (with Lens D)
  • Lenses Included:
    • Lens A: 18X-720X (Object distance: 12mm-320mm)
    • Lens L: 60X-240X (Object distance: 90mm-300mm)
    • Lens D: 1800X-2040X (Object distance: 4mm-5mm)
  • Ifihan: Integrated screen, supports HDMI output for larger field of view, USB output for PC connection.
  • Imọlẹ: 8 Awọn imọlẹ LED adijositabulu
  • Duro: Upgraded Plus Stand with Extension Base (30cm x 40cm x 33cm)
  • Awọn ẹya afikun: Soldering helping hands, tool holder, 100 grids compartment screw box, silicone soldering mat, IR remote control, 32G Micro SD card.
  • Ìwọ̀n Nkan: 7.39 iwon
  • Awọn iwọn idii: 17.5 x 10.8 x 6 inches
  • Olupese: Andonstar
  • Àwọ̀: Dudu
  • Ohun elo: Irin

8. Atilẹyin ọja ati Support

For warranty information and technical support, please refer to the official Andonstar webojula tabi kan si wọn onibara iṣẹ taara. Tọju iwe-ẹri rira rẹ fun awọn ẹtọ atilẹyin ọja.

O le ṣàbẹwò awọn Andonstar Store on Amazon fun alaye ọja diẹ sii ati awọn orisun atilẹyin.

© 2024 Andonstar. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.