RAF R.1175
RAF Electric Heater R.1175 User Manual
Model: R.1175 | Brand: RAF
1. Awọn Ilana Aabo pataki
Please read all instructions carefully before using this electric heater. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Aabo Itanna: Ensure the heater is connected to a 220V, 50Hz grounded outlet. Do not overload electrical circuits. Avoid using extension cords unless absolutely necessary and ensure they are rated for the heater's wattage (2400W).
- Ibi: Place the heater on a stable, level surface. Maintain a minimum distance of 1 meter (3 feet) from walls, furniture, curtains, and other combustible materials. Do not place the heater in areas where it may be exposed to water or high humidity.
- Afẹfẹ: Do not cover the heater or block its air inlets/outlets. Proper ventilation is essential to prevent overheating.
- Abojuto: Má ṣe fi ẹ̀rọ ìgbóná náà sílẹ̀ láìsí àbójútó nígbà tí o bá ń ṣiṣẹ́. Jẹ́ kí àwọn ọmọdé àti ẹranko jìnnà sí ibi tí ẹ̀rọ ìgbóná náà wà.
- Itọju: Yọọ ẹrọ alagbona nigbagbogbo kuro ninu iṣan agbara ṣaaju ṣiṣe itọju tabi ṣiṣe eyikeyi.
- Bibajẹ: Do not operate the heater with a damaged cord or plug, or if the heater has malfunctioned or been dropped. Contact qualified service personnel for repair.
- Lilo ti a pinnu: This heater is designed for indoor use only, specifically for heating rooms. Do not use it for drying clothes or other purposes.
2. Ọja Ipariview
The RAF Electric Heater R.1175 is a 2400W radiant heater designed to provide efficient warmth for indoor spaces. It features an adjustable temperature control for personalized comfort and is built for floor mounting.

Figure 2.1: RAF Electric Heater R.1175 and its packaging, highlighting key features.

olusin 2.2: Iwaju view of the RAF Electric Heater R.1175.
3. Imọ ni pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Brand | RAF |
| Nọmba awoṣe | R.1175 |
| Àwọ̀ | Pupa |
| Agbara (Wattage) | 2400W |
| Voltage | 220V |
| Igbohunsafẹfẹ | 50Hz |
| Pataki Awọn ẹya ara ẹrọ | Adijositabulu otutu |
| Iwọn Nkan | 2 kilo |
| Orisun agbara | Okun Itanna |
| Awọn iwọn Ọja (DxWxH) | 40 cm x 40 cm x 35 cm |
| Iṣagbesori Iru | Floor Oke |
| Yara Iru | Indoor Use (e.g., Study Room) |
| Alapapo Ideri | Titi di 250 sq ft |
| Alapapo Ano | Radiant |
4. Awọn ilana iṣeto
- Yọ Agbona kuro: Carefully remove the heater from its packaging. Retain packaging materials for future storage or transport.
- Ṣayẹwo fun ibajẹ: Before first use, inspect the heater for any signs of damage. Do not use if damaged.
- Yan Ibi kan: Place the heater on a firm, level, heat-resistant surface. Ensure there is at least 1 meter (3 feet) of clear space around the heater from all combustible materials (e.g., furniture, curtains, paper). Do not place it directly under a power outlet.
- Asopọ agbara: Ensure the heater's power cord is fully extended and not tangled. Plug the heater directly into a suitable 220V, 50Hz grounded wall outlet. Avoid using extension cords or power strips if possible. If an extension cord is necessary, ensure it is rated for 2400W or higher.
5. Awọn ilana Iṣiṣẹ
- Agbara Tan: Once plugged in, locate the power switch or knob on the heater. Turn it to the "ON" position or desired heat setting.
- Adjust Temperature/Heat Settings: The RAF R.1175 features adjustable temperature control. Rotate the thermostat knob (if present) or select the desired heat level (e.g., Low, Medium, High) to achieve your preferred room temperature. The heater will cycle on and off to maintain the set temperature.
- Lilo akọkọ: During the first few minutes of operation, a slight odor may be detected. This is normal and will dissipate quickly.
- Agbara Pa: To turn off the heater, switch the power control to the "OFF" position. Unplug the heater from the wall outlet when not in use for extended periods.
6. Itọju ati Ipamọ
- Ninu: Yọọ ẹrọ ti ngbona nigbagbogbo ki o jẹ ki o tutu patapata ṣaaju ṣiṣe mimọ. Lo asọ, damp Aṣọ láti nu àwọn ojú ìta. Má ṣe lo àwọn ohun ìfọṣọ tàbí àwọn ohun èlò ìfọṣọ. Rí i dájú pé omi kò wọ inú ohun èlò ìgbóná náà.
- Yiyọ eruku kuro: Periodically use a vacuum cleaner with a brush attachment to remove dust from the grilles and heating elements.
- Ibi ipamọ: When not in use, store the heater in a cool, dry place, preferably in its original packaging. Ensure the power cord is neatly wrapped and not kinked.
7. Laasigbotitusita
If your heater is not operating correctly, please check the following before contacting customer support:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Alagbona ko ni tan-an. | Not plugged in; Power outlet not working; Power switch is off; Overheat protection activated. | Ensure the plug is securely inserted. Test the outlet with another appliance. Turn the power switch to "ON". Unplug the heater, wait 10-15 minutes for it to cool down, then plug it back in. |
| Alagbona nmu ooru ti ko to. | Temperature setting is too low; Room is too large for the heater; Blocked air inlets/outlets. | Increase the temperature setting. Ensure the heater is appropriate for the room size (up to 250 sq ft). Clear any obstructions from the heater's grilles. |
| Ohun èlò ìgbóná máa ń mú ariwo tàbí òórùn tí kò wọ́pọ̀ jáde. | First-time use odor (normal); Internal component issue; Dust accumulation. | A slight odor is normal for initial use and will dissipate. If the noise or smell persists or is strong, unplug immediately and contact service. Clean dust from the heater. |
8. Atilẹyin ọja ati Onibara Support
For warranty information, please refer to the documentation provided with your purchase or contact the retailer. Keep your proof of purchase for warranty claims.
If you experience any issues not covered in the troubleshooting section, or require further assistance, please contact RAF customer support through their official channels or your point of purchase.