VEVOR LX-36575D

VEVOR Refrigerant Scale LX-36575D User Manual

Model: LX-36575D

1. Ti pariview

The VEVOR Refrigerant Scale LX-36575D is a high-precision electronic digital recovery weight scale designed for accurate measurement of refrigerants during HVAC charging and recovery processes. It features a robust design, a wired remote control for convenient operation, and intelligent power-saving functions.

Awọn ẹya pataki:

  • Wiwọn pipe: Maximum capacity of 220 lbs (100 kg) with 5g accuracy and 0.05% resolution.
  • Awọn Ẹka Ọpọ: Supports KG, OZ, and LB for versatile measurements.
  • Iṣakoso Latọna jijin ti firanṣẹ: Equipped with an HD LCD display and a 120° adjustable stand for easy data reading.
  • Ifipamọ Agbara: Automatic shut-off after 10 minutes of inactivity and backlight turns off after 3 minutes.
  • Ifọwọsi aabo: FCC and CE certified for enhanced safety and reliability.
  • Apẹrẹ to gbe: Housed in a waterproof and dustproof plastic case for secure transport and storage.
VEVOR Refrigerant Scale in use, showing the scale platform, refrigerant tank, and wired remote control.
Figure 1: VEVOR Refrigerant Scale in operation with a refrigerant tank and remote control.

This manual provides detailed instructions for the proper setup, operation, and maintenance of your VEVOR Refrigerant Scale LX-36575D.

2. Alaye Aabo

Please read all safety instructions carefully before using the VEVOR Refrigerant Scale to ensure safe and effective operation.

  • Always place the scale on a flat, stable, and level surface to ensure accurate readings and prevent tipping.
  • Do not exceed the maximum weight capacity of 220 lbs (100 kg). Overloading can damage the scale. The 'FULL' indicator will display if the limit is exceeded; remove weight immediately.
  • Keep the scale and remote control away from water, excessive moisture, and extreme temperatures.
  • Ma ṣe gbiyanju lati tu tabi tun ẹya ara rẹ ṣe. Tọkasi gbogbo iṣẹ si oṣiṣẹ oṣiṣẹ.
  • Use only the specified 9V dry battery. Remove the battery if the unit is not used for extended periods to prevent leakage and damage.
  • Ensure proper ventilation when working with refrigerants. Follow all industry safety standards for refrigerant handling.
  • The product is FCC and CE certified, indicating compliance with relevant safety and electromagnetic compatibility standards.

3. Package Awọn akoonu

Daju pe gbogbo awọn nkan wa ati ni ipo ti o dara nigbati ṣiṣi package naa:

  • 1 x Refrigerant Scale Platform
  • 1 x Wired Remote Control with LCD Display
  • 1 x 9V Dry Battery
  • 1 x Apo gbigbe
  • 1 x Itọsọna olumulo

4. Ọja irinše

4.1 Platform asekale

The scale platform is the main weighing surface. It features non-slip rubber pads to ensure stability for refrigerant tanks and prevent rolling or sliding during use.

4.2 Wired Remote Control

The remote control connects to the scale platform via a coiled cable. It houses the LCD display and control buttons, allowing for convenient operation and reading from a distance. An integrated 120° adjustable stand provides flexible viewing awọn igun.

VEVOR Refrigerant Scale platform and wired remote control.
Figure 2: Scale platform and wired remote control.

5. Eto

5.1 Fifi sori batiri

  1. Locate the battery compartment on the back of the wired remote control.
  2. Ṣii ideri iyẹwu batiri naa.
  3. Insert the included 9V dry battery, ensuring correct polarity (+/-).
  4. Pa ideri batiri naa ni aabo.
Close-up of the VEVOR Refrigerant Scale remote control with a 9V battery, illustrating battery insertion.
Figure 3: Battery installation in the remote control.

5.2 Iwon Gbe

Place the scale platform on a firm, flat, and level surface. An uneven surface can lead to inaccurate measurements. Ensure there are no obstructions beneath the scale that could interfere with its stability.

6. Isẹ

6.1 Agbara Tan / Pa

  • Lati fi agbara si iwọn, tẹ awọn TAN/PA button on the remote control. The LCD display will illuminate.
  • Lati fi agbara pa iwọn, tẹ mọlẹ TAN/PA bọtini titi ti ifihan yoo wa ni pipa.

6.2 Zeroing (Tare Function)

Before weighing a refrigerant tank, it is crucial to zero the scale to exclude the weight of the empty container.

  • With the scale powered on and nothing on the platform, press the Z/T (ZERO/TARE) button. The display will show '0.000' or '0.00' indicating it has been zeroed.
  • If you place an empty tank on the scale and then press Z/T, the display will reset to zero, allowing you to measure only the added refrigerant.

6.3 Unit Iyipada

The scale supports multiple units of measurement.

  • Tẹ awọn UNIT button to cycle through the available units: KG (kilograms), OZ (ounces), and LB (pounds).
  • Select the desired unit before or during the weighing process.

6.4 Backlight Išė

  • Tẹ awọn LAMP button to turn the LCD backlight on or off. This improves visibility in low-light conditions.
Alaye view of the VEVOR Refrigerant Scale remote control, highlighting the ON/OFF, ZERO, UNIT, and LAMP buttons and LCD display.
Figure 4: Remote control button functions.

6.5 Awọn Iṣẹ́ Àìfọwọ́ṣe

  • Tiipa Aifọwọyi: The scale will automatically power off after 10 minutes of inactivity to conserve battery life.
  • Backlight Auto Screen-off: The LCD backlight will turn off after 3 minutes of no operation.
Diagram illustrating the VEVOR Refrigerant Scale's auto shut-off after 10 minutes and backlight auto screen-off after 3 minutes.
Figure 5: Auto shut-off and backlight features.

7. Itọju

7.1 batiri Itọju

To prolong battery life and prevent potential damage from leakage, remove the 9V dry battery from the remote control if the scale will not be used for an extended period (e.g., several weeks or months).

7.2 Ninu

Wipe the scale platform and remote control with a soft, dry, or slightly damp cloth. Do not use abrasive cleaners, solvents, or immerse the unit in water. Ensure the unit is completely dry before storage or next use.

7.3 Ibi ipamọ

When not in use, store the refrigerant scale and its remote control in the provided waterproof and dustproof plastic carrying case. Ensure the case buckles are securely fastened to protect the components from environmental factors and physical damage.

VEVOR Refrigerant Scale's waterproof and dustproof carrying case with a secure buckle.
Figure 6: Carrying case for secure storage.

8. Laasigbotitusita

If you encounter issues with your VEVOR Refrigerant Scale, refer to the following common problems and solutions:

IsoroOwun to le FaOjutu
Awọn kika ti ko peScale not on a level surface; scale not zeroed; battery low.Ensure scale is on a flat, stable surface. Press Z/T to zero the scale before weighing. Replace battery if low.
Display shows 'FULL'Iwọn ju agbara ti o pọju lọ.Immediately remove the item from the scale to prevent damage. Do not exceed 220 lbs (100 kg).
Display not working / No powerBattery not installed correctly; battery depleted; loose cable connection.Check battery installation and polarity. Replace the 9V battery. Ensure the coiled cable is securely connected to both the platform and remote.
Imọlẹ afẹyinti ko ṣiṣẹBacklight turned off; auto screen-off activated; low battery.Tẹ awọn LAMP button to turn it on. If it turns off automatically, it's due to the energy-saving feature. Replace battery if low.

Ti iṣoro naa ba wa lẹhin igbiyanju awọn ojutu wọnyi, jọwọ kan si atilẹyin alabara VEVOR.

9. Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Nọmba awoṣeLX-36575D
O pọju Agbara220 LBS (100 kg)
Yiye5g
Ipinnu0.05%
Awọn iwọn wiwọnKG, OZ, LB
Orisun agbara1 x 9V Dry Battery (included)
Ọja Mefa42.49 x 30.99 x 6.6 cm (16.7 x 12.2 x 2.6 inches)
Iwọn Nkan3.25 kg (7.17 lbs)
Ohun eloRubber, Plastic
Ifihan IruLCD
Pataki Awọn ẹya ara ẹrọSmart, Auto Shut-off, Backlight, Overload Protection
Awọn iwe-ẹriFCC, CE
Diagram showing the dimensions of the VEVOR Refrigerant Scale platform, remote control, and carrying case, along with included accessories.
Nọmba 7: Awọn iwọn ọja ati awọn ẹya ẹrọ to wa.

10. Atilẹyin ọja & Atilẹyin

For detailed warranty information, technical assistance, or customer support regarding your VEVOR Refrigerant Scale LX-36575D, please refer to the warranty card included with your product or visit the official VEVOR website. You may also contact the retailer from whom you purchased the product for support.

Please have your model number (LX-36575D) and purchase date available when contacting support.