Thank you for choosing the ECOELER YWT102 4-Hour Countdown Timer Switch. This device is designed to provide convenient and energy-efficient control over your lights, fans, and other household appliances by automatically turning them off after a set period. Please read this manual thoroughly before installation and operation to ensure proper use and safety.

Ọja Awọn ẹya ara ẹrọ

  • 8 Pre-Set Countdown Options: Select from 1 min, 5 mins, 10 mins, 15 mins, 30 mins, 60 mins, 2 hours, or 4 hours.
  • Manual ON/OFF Override: Easily override any countdown setting for instant control.
  • Ifipamọ Agbara: Automatically turns off connected loads, preventing accidental energy waste.
  • Isẹ ti o rọrun: Features a Countdown mode and a Constant On mode.
  • Atọka LED: A blue LED light indicates the selected time and makes the switch easy to locate in the dark.
  • Ohun elo jakejado: Suitable for lights, ceiling fans, bathroom fans, and heaters in various rooms like bathrooms, closets, pantries, garages, and laundry rooms.
  • Awọn iwe-ẹri Abo: ETL listed, supporting LED/CFL, Incandescent (800W), Fluorescent (1200VA) light bulbs, and motors (1/2 HP).
ECOELER Countdown Timer Switch with LED indicators and control buttons
Image showing the ECOELER Countdown Timer Switch with its LED indicators for time settings and the manual ON/OFF button. The indicators show 1 min, 5 min, 10 min, 15 min, 30 min, 1H, 2H, and 4H options.

Alaye Aabo

  • IKILO: Láti yẹra fún iná, ìpayà, tàbí ikú, pa agbára ní ibi tí ẹ̀rọ ìfọ́mọ́ tàbí àpótí fiusi wà kí o sì dán an wò pé agbára náà ti pa kí o tó fi wáyà sí i.
  • Fi sori ẹrọ ni ibamu pẹlu gbogbo awọn koodu itanna ti orilẹ-ede ati ti agbegbe.
  • Use only with copper or copper clad wire.
  • This device requires a neutral wire for operation. If your switch box does not have a neutral wire, this product is not compatible.
  • Do not exceed the maximum load ratings: 15A, 120V AC, 60Hz. Incandescent: 800W, Fluorescent: 1200VA, LED/CFL: 600W, Motor: 1/2 HP.

Fifi sori ẹrọ

Follow these steps carefully for safe and correct installation:

  1. Pa Agbara: Locate the circuit breaker or fuse that controls the switch you are replacing and turn it off. Verify that the power is off using a voltage idanwo.
  2. Yọ Yipada atijọ kuro: Carefully remove the existing wall plate and switch from the electrical box. Disconnect the wires from the old switch.
  3. Ṣe idanimọ Awọn okun: Identify the following wires in your electrical box:
    • Load Wire (Red): Connects to the light or fan.
    • Hot Wire (Black): Incoming power from the circuit breaker.
    • Wáyà Dídúró (Fúúfù): Required for this timer switch.
    • Ground Wire (Green/Bare Copper): Fún ààbò.
  4. So Aago Yipada: Use the provided wire nuts to connect the wires from the electrical box to the corresponding wires on the ECOELER timer switch.
    • Sopọ awọn Pupa wire from the timer to the Fifuye wire from the box.
    • Sopọ awọn Dudu wire from the timer to the Gbona wire from the box.
    • Sopọ awọn Funfun wire from the timer to the Àdánù wire from the box.
    • Sopọ awọn Alawọ ewe wire from the timer to the Ilẹ wire from the box.
  5. Gbe Iyipada naa: Carefully push the wired switch into the electrical box. Secure it with the mounting screws.
  6. Fi Awo Odi sori ẹrọ: Attach the included wall plate.
  7. Pada Agbara pada: Tan agbara pada si ẹrọ fifọ.
Wiring diagram for ECOELER Countdown Timer Switch showing connections for Load, Hot, Ground, and Neutral wires.
Detailed wiring diagram for the timer switch. Note: A neutral wire is required for installation.

Isẹ

The ECOELER YWT102 timer switch offers two primary modes of operation: Countdown Mode and Constant On Mode.

Ipo Kika

This mode allows you to set the connected load to turn off automatically after a specified duration.

  1. Yan Akoko: Press the "Timer Select Button" (up/down arrows) to cycle through the available countdown options: 1 min, 5 mins, 10 mins, 15 mins, 30 mins, 60 mins, 2 hours, or 4 hours. The corresponding LED indicator will light up.
  2. Bẹ̀rẹ̀ kíkà ìsàlẹ̀: Press the large "Manual ON/OFF" button once. The connected light or fan will turn on, and the countdown will begin. The timer will remember the last selected time for future use.
  3. Cancel Countdown: To turn off the load before the countdown completes, press the "Manual ON/OFF" button again.

Constant On Mode (Manual Override)

This mode keeps the connected load continuously on, bypassing the countdown timer.

  • Activate Constant On: With the load off, press and hold the "Manual ON/OFF" button for more than 5 seconds. The load will turn on and remain on indefinitely.
  • Deactivate Constant On: To turn off the load from Constant On mode, press the "Manual ON/OFF" button once.
ECOELER Countdown Timer Switch in a bathroom setting, demonstrating wide applicability.
The timer switch installed in a bathroom, illustrating its use for controlling exhaust fans or lighting.

Awọn pato

Ẹya ara ẹrọSipesifikesonu
Nọmba awoṣeYWT102
Ipo IsẹON-OFF, Countdown Timer
Ti isiyi Rating15 Amps
Awọn ọna Voltage120 Volt (AC)
Wattage1800 watt
Ibamu FifuyeIncandescent: 800W, Fluorescent: 1200VA, LED/CFL: 600W, Motor: 1/2 HP
Yipada IruPush Button, Countdown Timer
Iṣagbesori IruÒgiri Ògiri
Ọna IṣakosoFọwọkan
Ohun eloCopper, Metal, Polycarbonate
Awọn Iwọn Nkan (L x W x H)42 x 37 x 120 millimeters (1.65 x 1.46 x 4.72 inches)
Oke otutu RatingAwọn iwọn Celsius 50
International Idaabobo RatingIP40
Awọn iwe-ẹriFCC, cETL
Ailopin Waya beereBẹẹni
Dimensions of the ECOELER Countdown Timer Switch and included components: wire nuts, timer switch, and free plate.
Physical dimensions of the timer switch and a view ti awọn eroja ti o wa ninu package naa.

Laasigbotitusita

IsoroOwun to le Fa / Solusan
Switi naa ko tan/pa.
  • Ṣayẹwo ti o ba jẹ pe fifọ Circuit ti kọlu.
  • Rii daju pe gbogbo awọn asopọ waya wa ni aabo.
  • Rii daju pe okun waya didoju ti sopọ ni deede.
  • Confirm the load does not exceed the switch's maximum rating.
Àwọn àmì LED kò ń tan ìmọ́lẹ̀.
  • Ṣayẹwo ipese agbara si yipada naa.
  • Ensure the switch is correctly wired, especially the neutral connection.
Timer does not count down or turns off prematurely.
  • Ensure the correct countdown time is selected.
  • Avoid holding the ON/OFF button for too long, which activates Constant On mode.

Itoju

The ECOELER YWT102 Countdown Timer Switch requires minimal maintenance. To ensure longevity and proper function:

  • Ninu: Wipe the switch and wall plate with a soft, damp asọ. Ma ṣe lo abrasive ose tabi epo.
  • Awọn iṣayẹwo deede: Periodically check for any loose connections or signs of wear. If any issues are found, turn off power at the circuit breaker before inspecting.

Atilẹyin ọja ati Support

Atilẹyin ọja: Ọja yii wa pẹlu atilẹyin ọja ọdun kan lati ọjọ rira.

Atilẹyin Onibara: If you have any questions, require assistance, or encounter issues with your ECOELER Countdown Timer Switch, please contact ECOELER ELECTRIC INC customer support.

Imeeli: SUPPORTS@ECOELER.COM