1. Ifihan
The Generic SW18C Electric Shockwave Therapy Machine is designed for muscle relaxation and pain relief through extracorporeal shockwave therapy. This device utilizes focused shockwaves to target painful areas of the body, promoting improved blood circulation, bone healing, and reduction in tissue tension. It is intended for home use and offers a range of treatment options for various body parts.
2. Alaye Aabo
- Iṣakoso iwọn otutu: The machine is equipped with a temperature control program. It will automatically shut down if it reaches a certain temperature to protect the handle coil from overheating. Allow the device to cool down completely before resuming use.
- Lilo to tọ: Always follow the instructions provided in this manual for proper usage. Misuse may lead to injury or device damage.
- Imọran Oogun: A kò ṣe ẹ̀rọ yìí láti ṣe àyẹ̀wò, tọ́jú, wo àrùn sàn, tàbí dènà àrùn tàbí àìsàn èyíkéyìí. Kan sí onímọ̀ nípa ìlera fún èyíkéyìí ìṣòro ìlera.
- Awọn ọmọde ati awọn ohun ọsin: Jeki ẹrọ naa kuro ni arọwọto awọn ọmọde ati awọn ohun ọsin.
- Orisun Agbara: Use only the specified power source (AC110V-AC220V, 50HZ/60HZ) to prevent electrical hazards.
3. Package Awọn akoonu
Fi pẹ̀lẹ́pẹ̀lẹ́ tú àpótí náà kí o sì rí i dájú pé gbogbo àwọn ohun tí a kọ sí ìsàlẹ̀ wà níbẹ̀, wọ́n sì wà ní ipò tó dára. Tí àwọn ohun kan bá sọnù tàbí tí wọ́n bá bàjẹ́, jọ̀wọ́ pe olùrànlọ́wọ́ oníbàárà.
- 1 x Host Unit
- 1 x Handle with Wire
- 7 x Massage Heads (various types)
- 4 x Blue Massage Silicone Head Covers
- 3 x Grey Massage Silicone Head Covers
- 1 x Power Plug

Image: All components included in the SW18C Electric Shockwave Therapy Machine package.
4. Eto
4.1. Apejọ
- Place the host unit on a stable, flat surface.
- Connect the handle wire to the designated port on the host unit. Ensure a secure connection.
4.2. Asopọ agbara
- Insert the power plug into the power input port on the host unit.
- Plug the power adapter into a suitable electrical outlet (AC110V-AC220V).
4.3. So Àwọn Orí Ìfọwọ́ra Mọ́ra
- Select the appropriate massage head for your desired treatment area.
- Gently twist or push the chosen massage head onto the end of the handle until it is firmly attached.
- For comfort and hygiene, you may place a silicone cover over the massage head.

Image: The device handle with various treatment heads and a diagram illustrating the wide range of applicable body areas.
5. Awọn ilana Iṣiṣẹ
5.1. Ipilẹ isẹ
- Press the power button on the host unit to turn on the device. The LCD display will illuminate.
- The display will show various settings and options. Use the control buttons to navigate the menu.
- Select the desired treatment area or program if available.
5.2. Siṣàtúnṣe Eto
- Igbohunsafẹfẹ: Adjust the output frequency (1-16Hz) according to your comfort level and treatment needs. Higher frequencies may be used for superficial areas, while lower frequencies are often preferred for deeper tissues.
- Kikunra: Adjust the output intensity (60-200mJ) to control the strength of the shockwave. Start with a lower intensity and gradually increase it until a comfortable yet effective level is reached.
- Ipele Ijade: The device offers 12 output levels for fine-tuning the treatment.
5.3. Application Areas and Effects
The shockwave therapy machine can be applied to various parts of the body for different therapeutic effects:
- Iderun irora: Effective for reducing bone pain and discomfort in areas like the back, shoulder, elbow, hip, knee, and ankle.
- Isinmi Isan: Used for body massage, relieving fatigue, and reducing stress on surrounding tissues.
- Chronic Soft Tissue Injuries: May be used for conditions such as arthritis, tenosynovitis, and patellar tendinitis.
- Circulation Improvement: Supports improvement of blood circulation and macro-circulation.
- Tissue Regeneration: Aids in bone healing and remodeling, supports collagen production, and can assist in the dissolution of calcified fibroblasts.

Image: Visual representation of the various therapeutic effects of shockwave therapy.

Aworan: Examples of applicable situations for using the shockwave therapy machine.
6. Itọju
6.1. Ninu
- Paa nigbagbogbo ati yọọ ẹrọ naa kuro ṣaaju ṣiṣe mimọ.
- Wipe the host unit and handle with a soft, damp asọ. Ma ṣe lo awọn olutọpa abrasive tabi fi ẹrọ bọ inu omi.
- Clean massage heads and silicone covers with mild soap and water, then dry thoroughly before storage.
6.2. Ibi ipamọ
- Tọju ẹrọ naa ni itura, aye gbigbẹ, kuro lati orun taara ati awọn iwọn otutu to gaju.
- Keep all components, especially the massage heads and handle, in their designated storage areas or original packaging to prevent damage.
7. Laasigbotitusita
- Ẹrọ Ko Tii: Ensure the power plug is securely connected to both the device and the electrical outlet. Check if the outlet is functional.
- Ohun elo gbigbona: If the machine becomes excessively hot during operation, it will automatically shut down. This is a normal protective feature. Allow the device to cool down completely before attempting to use it again. Ensure adequate ventilation around the unit.
- No Shockwave Output: Verify that the handle is properly connected to the host unit and that a massage head is securely attached. Check the intensity settings on the display.
- Awọn ariwo ti ko wọpọ tabi awọn oorun: Immediately turn off and unplug the device. Do not attempt to operate it. Contact customer support for assistance.
8. Awọn pato
| Paramita | Iye |
|---|---|
| Orukọ ọja | ED shockwave machine |
| Orukọ awoṣe | SW18C Extracorporeal Shockwave Therapy Machine |
| Voltage | AC110V-AC220V |
| Igbohunsafẹfẹ | 50HZ/60HZ |
| Agbara | 90W Max |
| Lọwọlọwọ | 2A Max |
| Output Frequency Numbers | 16 |
| Output Level Numbers | 12 |
| Heads Numbers | 7 awọn kọnputa |
| Ọja Mefa | 15 x 10 x 5 inches |
| Iwọn Nkan | 7.05 iwon (3.2 kilo) |
| Orisun agbara | Okun Itanna |
| Other Special Features | Ifihan LCD |
| Fọọmu Massager | Ibon Ifọwọra |
| Massage Therapy Technique | Percussion |
| Ohun elo Iru | Aluminiomu |
9. Atilẹyin ọja ati Support
For any questions, technical support, or if you require an electronic version of this instruction manual, please contact the manufacturer or seller directly. Please refer to your purchase documentation for specific warranty details.
Àkíyèsí: FDA kò tíì ṣe àyẹ̀wò àwọn gbólóhùn nípa àwọn afikún oúnjẹ, wọn kò sì ṣe é láti ṣe àyẹ̀wò, tọ́jú, wòsàn, tàbí dènà àrùn tàbí àìsàn èyíkéyìí.