Irfora YR2050

Irfora YAOREA YR2050 High-Precision 4-Wire Portable Milliohm Meter User Manual

Àwòṣe: YR2050

1. Ifihan

The Irfora YAOREA YR2050 is a high-precision, portable 4-wire milliohm meter designed for accurate resistance measurements. This device is ideal for quick testing of wire length, resistivity, and assessing the quality of power cords for motors and transformers. Its portable design ensures ease of use in various environments.

This meter can test resistances in components such as transformers, motors, and large inductance inductors. Its high accuracy also allows for the detection of resistance in precision current-sense resistors.

2. Alaye Aabo

  • Prohibited Measurements: It is strictly prohibited to measure any live parts, such as AC or DC voltage input to the test interface. Doing so may cause severe damage to the instrument and pose a safety risk to the user.
  • Battery Internal Resistance: The YR2050 meter cannot measure the internal resistance of batteries. Attempting to do so may yield inaccurate results or damage the device.
  • Ayika Ṣiṣẹ: Use the device within the specified working temperature range of 10 ℃ to 40 ℃.
  • Idaabobo fiusi: The device is protected by a 0.5A fuse. Do not attempt to bypass or replace with an incorrect fuse rating.

3. Ọja Ipariview ati irinše

The YAOREA YR2050 Milliohm Meter package includes the following items:

  • 1 x YAOREA YR2050 Milliohm Meter
  • 1 x Set of Test Clips (Red and Black)
  • 1 x Okun Ngba agbara USB
YAOREA YR2050 Milliohm Meter connected with red and black test clips.

The YAOREA YR2050 Milliohm Meter with its display showing a reading, connected to a test object using the included red and black test clips.

Included test clips and USB charging cable for the YAOREA YR2050 Milliohm Meter.

A set of red and black test clips and a USB charging cable, essential accessories for the YAOREA YR2050 Milliohm Meter.

4. Eto

The YAOREA YR2050 comes with a pre-installed 2000 mAh lithium battery. Ensure the device is charged before first use. Connect the USB charging cable to the meter and a suitable USB power source.

4.1 Connecting Test Clips

  1. Identify the red and black test clips.
  2. Connect the red test clip to the positive (+) terminal and the black test clip to the negative (-) terminal on the meter's test interface. Ensure a secure connection for accurate readings.

5. Awọn ilana Iṣiṣẹ

The YAOREA YR2050 offers various measurement modes for different applications.

5.1 General Resistance Measurement

  1. Agbara lori ẹrọ nipa lilo bọtini agbara ti a yan.
  2. Select the appropriate measurement range if not in auto-ranging mode. Refer to the button layout image for 'range' selection.
  3. Connect the test clips to the component or wire you wish to measure. Ensure good contact.
  4. Ka iye resistance ti o han loju iboju.
Close-up of the YAOREA YR2050 Milliohm Meter display and control buttons.

A alaye view of the YAOREA YR2050 Milliohm Meter's interface, highlighting the display and control buttons for menu, range, hold, and selection functions.

5.2 Wire Resistivity Measurement

This function helps determine if the wire material is pure copper by calculating its resistivity.

  1. Intercept a specific length of the wire to be tested.
  2. Accurately measure the diameter of the wire to calculate its cross-sectional area.
  3. Enter the instrument's detection mode for resistivity measurement.
  4. Input the corresponding parameters (wire length, cross-sectional area) into the device.
  5. Measure the resistance of the wire using the test clips.
  6. The device will calculate and display the resistivity, allowing you to determine the wire material's quality.
YAOREA YR2050 Milliohm Meter demonstrating wire resistance measurement.

The YAOREA YR2050 Milliohm Meter in use, showing how to connect to a wire for resistance measurement to determine resistivity and material quality.

5.3 Transformer Winding Qualification Test

This feature allows you to check if a transformer winding meets specified resistance limits.

  1. Enter the normal mode on the instrument.
  2. Access the settings to open the upper and lower limits for resistance.
  3. Input the desired upper and lower resistance limits for the transformer winding.
  4. Connect the test clips to the transformer winding.
  5. The device will measure the winding's resistance and indicate if it falls within the set limits, thus determining its qualification.
Examples of applications for the YAOREA YR2050 Milliohm Meter, including resistance testing, transformers, motors, and large inductors.

This image illustrates various applications for the milliohm meter, such as testing resistance in circuit boards, checking transformers, evaluating motors, and measuring large inductors.

6. Itọju

  • Ninu: Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Ibi ipamọ: When not in use, store the meter in a dry place, away from direct sunlight and extreme temperatures. The recommended storage temperature is -20 ℃ to 60 ℃.
  • Itọju Batiri: Ṣe àtúnṣe agbára bátìrì déédéé, kódà bí ẹ̀rọ náà kò bá tiẹ̀ ń lò ó déédéé, láti lè mú kí bátìrì ní ìlera tó dára.
  • Test Clips: Inspect the test clips periodically for any signs of wear or damage. Replace them if necessary to ensure accurate and safe measurements.

7. Laasigbotitusita

  • Kò sí kíkà/Kíkà Àìdára:
    • Ensure test clips are securely connected to both the meter and the object under test.
    • Ṣayẹwo boya batiri ti gba agbara to.
    • Verify that the measurement range is appropriate for the expected resistance value.
  • Ẹrọ ti ko ni agbara:
    • Charge the battery for at least 30 minutes.
    • Rii daju pe bọtini agbara ti tẹ ni deede.
  • Damage After Measurement:
    • If the device was connected to live voltage (AC/DC), it might be damaged. Refer to the safety information. Such damage is typically not user-repairable.

8. Awọn pato

Ẹya ara ẹrọSipesifikesonu
AwoṣeYR2050
Ohun eloṢiṣu
IpinnuAwọn iṣiro 120000
Fuse Current Protection0.5A
Awọn iwọn otutu ṣiṣẹ10 ℃ ~ 40 ℃ (50 ℉ ~ 104 ℉)
Ibi ipamọ otutu-20 ℃ ~ 60 ℃ (-4 ℉ ~ 140 ℉)
Batiri1 x Lithium battery, 2000 mAh (included)
Ọja Mefa12 x 6 x 4 cm (4.7 x 2.4 x 1.6 inches)
Package iwuwo300 g (10.6 iwon)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.