EasyByMall DSO510

DSO510 Compact Digital Oscilloscope User Manual

Awoṣe: DSO510

Brand: EasyByMall

1. Ifihan

The DSO510 is a compact and versatile digital oscilloscope designed for convenient use in various environments. It features a real-time sampling rate of 48 MS/s and a 10 MHz bandwidth, making it suitable for both periodic analog and non-periodic digital signals. With its intuitive automatic function, users can quickly display measured waveforms without complex adjustments.

This manual provides detailed instructions on the setup, operation, and maintenance of your DSO510 oscilloscope. Please read it thoroughly before using the device to ensure proper and safe operation.

2. Awọn ẹya Ọja

  • Iṣe to gaju: 48 MS/s real-time sampling rate and 10 MHz bandwidth.
  • Jakejado Voltage Ibiti: Awọn iwọn voltages up to ±400 V (X10 probe setting).
  • Iṣẹ Aifọwọyi: One-button auto-adjustment for quick waveform display.
  • Ẹ̀rọ ìṣiṣẹ́ àmì-ìdámọ̀ràn: Built-in 50 kHz function signal generator with various waveform types.
  • Ko Ifihan kuro: 2.8-inch 320x240 high-definition LCD screen.
  • Apẹrẹ to gbe: Compact size (99 x 68.3 x 19.5 mm) and lightweight (294g).
  • Igbesi aye batiri gigun: Built-in 1000 mAh lithium battery provides approximately 4 hours of continuous use.
  • Ngba agbara USB: Convenient 5V/1A USB charging.
  • Iduro ti o le ṣe pọ: Integrated stand for hands-free operation.
DSO510 Oscilloscope and Signal Generator

Image: The DSO510 combines the functions of a 10MHz oscilloscope and a signal generator in one compact device.

DSO510 with foldable stand and gear toggle button

Image: The DSO510 features a foldable stand for hands-free use and a gear toggle button for easy adjustments.

3. Package Awọn akoonu

Daju pe gbogbo awọn nkan ti a ṣe akojọ rẹ si isalẹ wa ninu package rẹ:

  • 1 x DSO510 Host Unit
  • 1 x P6100 High-Voltage Iwadii
  • 1 x Adapter
  • 1 x Alligator Agekuru ibere
  • 1 x Okun gbigba agbara (USB)
  • 1 x Lanyard
  • 1 x Itọsọna olumulo
DSO510 Oscilloscope and included accessories

Image: The DSO510 package includes the main unit, high-voltage probe, alligator clip probe, charging cable, adapter, and lanyard.

DSO510 with USB charging cable connected

Image: The DSO510 can be conveniently charged via its USB port using the included charging cable.

4. Awọn pato

ParamitaIye
AwoṣeDSO510
Akoko gidi SampOṣuwọn ling48 MS/s
Bandiwidi10 MHz
Inaro ifamọ10 mV / div - 10 V / div
Time Mimọ Range50 ns/div - 20 s/div
Voltage Range (X1 Probe)±40 V (Vpp: 80 V)
Voltage Range (X10 Probe)±400 V (Vpp: 800 V)
Awọn ipo okunfaAifọwọyi, Deede, Nikan
Nfa EdgeRising Edge / Falling Edge
Coupling ModesAC / DC
Calibration Square WaveFrequency: 1 KHz; Duty Cycle: 50%; Amplitude: 3.3 V
Ifihan agbara monomono Igbohunsafẹfẹ0-50 kHz
Signal Generator Duty Cycle0-100% (Square wave, Sawtooth wave)
Monomono ifihan agbara Amplitude0.1-3.0 V
Signal monomono WaveformsSine wave, Square wave, Sawtooth wave, Half wave, Full wave, Positive step wave, Inverse step wave, Exponential rise, Exponential fall, DC signal, Multi-audio, Sink pulse, Lorentz wave
Iboju ifihan2.8" LCD, 320 x 240 resolution
Ngba agbara USB5V/1 A
Agbara Batiri Litiumu1000 mAh
Awọn iwọn (L x W x H)99 x 68.3 x 19.5 mm
Iwọn294 g
Àwọ̀Dudu ati Blue
Comparison table of DSO510 specifications with other models

Image: Detailed specifications of the DSO510, highlighting its capabilities compared to similar models.

5. Eto

5.1 Gbigba agbara akọkọ

Before first use, fully charge the DSO510. Connect the included USB charging cable to the device's USB port and a 5V/1A USB power adapter (included) or a computer USB port. The charging indicator will show the charging status. A full charge takes approximately 4 hours and provides up to 4 hours of continuous operation.

5.2 Attaching the Probe

Connect the BNC connector of the high-voltage probe (P6100) to the BNC input port on the DSO510. Ensure a secure connection by twisting the connector until it locks into place.

5.3 Probe Compensation (Recommended)

For accurate measurements, it is recommended to compensate the probe. Connect the probe tip to the calibration signal output (usually a 1KHz square wave) on the oscilloscope. Adjust the compensation trimmer on the probe until the square wave displayed on the screen has flat tops and bottoms without overshoot or undershoot.

5.4 Setting Probe Ratio

Ensure the probe ratio setting on the DSO510 matches the physical switch setting on your probe (1X or 10X). If the probe is set to 1X, the oscilloscope should also be set to 1X. A 1X setting measures voltages up to ±40 V, while a 10X setting measures up to ±400 V.

6. Awọn ilana Iṣiṣẹ

6.1 Agbara Tan / Pa

Press and hold the power button (usually located on the side or bottom) to turn the device on or off.

6.2 Automatic Measurement (AUTO Button)

For quick setup and display of a stable waveform, press the AUTO button. The oscilloscope will automatically adjust the time base, vertical sensitivity, and trigger settings to display the measured waveform.

6.3 Navigating Menus and Adjusting Parameters

Use the navigation buttons (up/down/left/right) and the MODE button to navigate through menus and adjust parameters. The gear toggle button on the side can also be used for quick adjustments.

6.4 Awọn ọna okunfa

The DSO510 supports three trigger modes:

  • Laifọwọyi: Automatically triggers and displays the waveform, even if the signal is unstable.
  • Deede: Triggers only when the signal meets the trigger conditions. If no trigger occurs, the display remains unchanged.
  • Nikan: Captures a single waveform when the trigger condition is met and then stops.

6.5 Waveform Adjustment After Pause

When the measurement waveform is paused (STOP mode):

  • Yipada MODE to "V H". The wheel button controls the time base (horizontal scale), and the up/down keys control the channel vertical sensitivity.
  • Yipada MODE to the arrow keys. The wheel button controls horizontal trigger movement, and the up/down keys control waveform vertical movement.
Waveform adjustment examples after pausing measurement

Image: Instructions on how to adjust the waveform display, including time base, vertical sensitivity, and horizontal/vertical positioning, after pausing the measurement.

Examples of pulse signal detection and other waveform measurements

Image: The DSO510 is capable of detecting various signal types, including pulse signals and other complex waveforms.

7. Awọn afihan Ifihan

The DSO510 display provides various indicators to help you interpret measurements:

  1. Vertical Unit: Aṣoju voltage value for one large grid in the vertical direction.
  2. Trigger Mode Indicator: Displays "Auto" for automatic trigger, "Single" for single trigger, and "Normal" for normal trigger.
  3. Probe Ratio: Must be consistent with the 1X/10X switch setting on the probe handle.
  4. Input Coupling Mode Indicator: "AC" indicates AC coupling, "DC" indicates DC coupling.
  5. Nfa Voltage Atọka: Shows the current trigger voltage ipele.
  6. Trigger Position Indicator: Indicates the horizontal position of the trigger point.
  7. Baseline Indicator: Shows the 0V reference line.
  8. Time Base Indicator: Represents the duration for one large grid in the horizontal direction.
  9. Pause Indicator: "RUN" means operation, "STOP" means pause.
  10. Trigger Edge Indicator: Shows whether the trigger is set to rising or falling edge.

8. Signal monomono Išė

The DSO510 includes a built-in signal generator capable of producing various waveforms with adjustable frequency, duty cycle, and amplitude.

  • Iwọn Igbohunsafẹfẹ: 0-50 kHz
  • Àyíká Iṣẹ́: 0-100% (for square and sawtooth waves)
  • Ampkekere: 0.1-3.0 V
  • Awọn oriṣi Waveform: Sine wave, Square wave, Sawtooth wave, Half wave, Full wave, Positive step wave, Inverse step wave, Exponential rise, Exponential fall, DC signal, Multi-audio, Sink pulse, Lorentz wave.

To access and configure the signal generator, refer to the specific menu options on the device. Use the navigation buttons to select the desired waveform type and adjust its parameters.

9. Itọju

9.1 Ninu

Fi aṣọ rírọrùn àti gbígbẹ nu ẹ̀rọ náà. Má ṣe lo àwọn ohun ìfọṣọ tàbí àwọn ohun èlò ìfọṣọ, nítorí wọ́n lè ba c jẹ́.asing or screen. Ensure the device is powered off before cleaning.

9.2 Ibi ipamọ

Store the DSO510 in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity. When storing for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.

9.3 batiri Itọju

The device uses a built-in lithium battery. Avoid fully discharging the battery frequently. If the device will not be used for a long time, charge it every 3-6 months to prevent deep discharge.

10. Laasigbotitusita

IsoroOwun to le FaOjutu
Ẹrọ naa ko ṣiṣẹ.Batiri kekere; Agbara bọtini ko te gun to.Charge the device for at least 30 minutes. Press and hold the power button for 3-5 seconds.
Kò sí ìgbì tí a fihàn tàbí ìgbì tí kò dúró ṣinṣin.Incorrect probe connection; Incorrect trigger settings; Signal too small or too large; Probe ratio mismatch.Rii daju pe iwadii ti sopọ ni aabo. Tẹ awọn AUTO button. Adjust vertical sensitivity (V/div) and time base (s/div). Verify probe ratio setting matches physical probe switch.
Waveform is distorted (e.g., rounded corners on square wave).Probe compensation issue.Perform probe compensation as described in Section 5.3.
Batiri n ṣan ni kiakia.Aging battery; Continuous high-intensity use.Ensure the device is fully charged. Reduce screen brightness if possible. If battery life significantly degrades, contact customer support.

11. Atilẹyin ọja ati Support

This product is covered by a standard manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your retailer.

For technical support, troubleshooting assistance, or inquiries regarding replacement parts, please contact EasyByMall customer service. Please have your product model (DSO510) and serial number (if applicable) ready when contacting support.

Olupese: EasyByMall

Nọmba awoṣe: H2SV732SH08P7G239N2441

ASIN: B0DLBF6183

© 2024 EasyByMall. All rights reserved.