WOOXGEHM T6125

WOOXGEHM T6125 Digital Insulation Resistance Tester User Manual

awoṣe: T6125

1. Ifihan

This manual provides detailed instructions for the safe and effective operation of the WOOXGEHM T6125 Digital Insulation Resistance Tester. The T6125 is a robust, shockproof, and dustproof instrument designed for measuring insulation resistance, absorption ratio (DAR), polarization index (PI), AC voltage, and low resistance. It features a wide measurement range, multiple output voltage levels, a large LCD with backlight, and strong anti-interference capabilities, making it suitable for various electrical equipment testing applications.

WOOXGEHM T6125 Digital Insulation Resistance Tester front view

Figure 1: WOOXGEHM T6125 Digital Insulation Resistance Tester.

2. Alaye Aabo

To ensure safe operation and prevent damage to the instrument or injury to personnel, please read and understand all safety instructions before use.

  • Always observe local and national safety codes.
  • Do not operate the tester if it appears damaged or is not functioning properly.
  • Ensure the circuit under test is de-energized and discharged before connecting test leads for resistance measurements.
  • Use only the provided test leads and accessories.
  • Avoid touching the test leads or the circuit under test during measurement, especially when high voltages wa.
  • Do not use the instrument in wet environments or explosive atmospheres.
  • Rọpo awọn batiri ni kiakia nigbati atọka batiri kekere ba han.

3. Package Awọn akoonu

Daju pe gbogbo awọn nkan ti a ṣe akojọ rẹ si isalẹ wa ninu package rẹ:

  • 1 x WOOXGEHM T6125 Digital Insulation Resistance Tester
  • 1 x Tọkọtaya Awọn itọsọna Igbeyewo
  • 1 x External Power Plug (5.5mm)
  • 2 x Alligator Clips
  • 1 x Apo Aṣọ
  • 1 x Afọwọṣe olumulo (Gẹẹsi)

4. Ọja Ipariview

The T6125 insulation tester is designed for comprehensive electrical insulation testing. Key features include:

  • Iwọn Atako Idabobo: Measures insulation opposition, absorption ratio, and polarization index.
  • AC Voltage Iwọn: Capable of measuring AC voltage.
  • Low Resistance Measurement: For continuity checks.
  • Multiple Test Voltages: Offers 100V, 250V, 500V, 1000V, and 2500V test voltage awọn aṣayan.
  • Automatic Discharge Function: Ensures safety after high voltage idanwo.
  • Idaduro data: Freezes the displayed measurement for easy recording.
  • Over-range Alarm: Alerts the user when measurements exceed the selected range.
  • Tiipa Aifọwọyi: A máa pa agbára lẹ́yìn ìṣẹ́jú márùn-ún tí a kò bá ṣiṣẹ́ láti fi pa agbára bátírì mọ́.
  • Large Backlit LCD: Pese awọn kika ti o han gbangba ni awọn ipo ina oriṣiriṣi.
  • Apẹrẹ ti o tọ: Shockproof, dustproof, and dampness-proof construction.
Labeled components of the WOOXGEHM T6125 Insulation Resistance Tester

Figure 2: Front panel layout and key components of the T6125.

  • Gaju gigatage Output Black Negative Jack: Connects the negative test lead for high voltage idanwo.
  • Gaju gigatage Output Red Positive Jack: Connects the positive test lead for high voltage idanwo.
  • Resistor Red Positive Jack: Connects the positive test lead for resistance measurements.
  • Resistive Black Negative Jack: Connects the negative test lead for resistance measurements.
  • 12V Power Input Jack: Fun ipese agbara ita.
  • Ifihan LCD: Shows measurement readings and status.
  • Bọtini Idanwo: Bẹrẹ wiwọn kan.
  • Bọ́tìnì Dídá Dátà Mọ́: Freezes the current display.
  • Bọtini Imọlẹhin: Ó ń mú kí ìmọ́lẹ̀ ẹ̀yìn LCD ṣiṣẹ́/paá.
  • DAR (Absorption Ratio) / PI (Polarization Index) Button: Selects DAR or PI measurement mode.
  • Gear Rotary Switch: Selects measurement function and test voltage.
WOOXGEHM T6125 with automatic shutdown feature indicated

Figure 3: The T6125 features an automatic shutdown function after 30 minutes of inactivity to conserve battery life.

5. Eto

5.1 Fifi sori batiri

The T6125 requires 8 x 1.5V AA batteries (not included).

  1. Wa awọn yara batiri lori pada ti awọn kuro.
  2. Ṣii ideri iyẹwu batiri naa.
  3. Fi awọn batiri AA 8 sii, ni idaniloju polarity ti o pe (+/-).
  4. Pa ideri batiri naa ni aabo.

5.2 Nsopọ Awọn itọsọna Igbeyewo

Connect the test leads to the appropriate jacks on the front panel based on the measurement type. For insulation resistance tests, use the High Voltage Output jacks. For low resistance, use the Resistor jacks.

6. Awọn ilana Iṣiṣẹ

6.1 Agbara Tan / Pa

Rotate the Gear Rotary Switch from the "OFF" position to any measurement function to power on the device. Rotate back to "OFF" to power off. The device will automatically shut down after 30 minutes of inactivity.

6.2 Idabobo Idiwon Resistance

This function measures the insulation resistance of electrical equipment.

  1. Rí i dájú pé a ti dín agbára ìṣiṣẹ́ tí a ń dán wò kù, a sì ti yọ ọ́ kúrò láìléwu.
  2. Connect the test leads to the High Voltage Output jacks (red to positive, black to negative).
  3. Connect the other ends of the test leads to the insulation points of the equipment to be tested.
  4. Rotate the Gear Rotary Switch to the desired insulation test voltage (e.g., 100V, 250V, 500V, 1000V, 2500V).
  5. Tẹ mọlẹ Idanwo button. The measurement will begin, and the resistance value will be displayed on the LCD.
  6. Tu silẹ Idanwo button to stop the measurement. The instrument will automatically discharge the circuit.
  7. Láti di kíkà náà mú, tẹ DIMU button during or after a measurement. Press again to release.
WOOXGEHM T6125 displaying insulation resistance measurement range

Figure 4: The T6125 offers a wide insulation test measurement range up to 2500V and 200.0GΩ.

6.3 Absorption Ratio (DAR) and Polarization Index (PI) Measurement

DAR and PI are used to assess the quality of insulation over time.

  1. Follow steps 1-3 for Insulation Resistance Measurement.
  2. Rotate the Gear Rotary Switch to the desired insulation test voltage.
  3. Tẹ awọn DAR/PI button to select the desired mode. The display will indicate "DAR" or "PI".
  4. Tẹ mọlẹ Idanwo button. The instrument will automatically perform the timed measurements and display the DAR or PI value.
  5. Tu silẹ Idanwo bọtini.

6.4 AC Voltage Idiwon

Lati wiwọn AC voltage:

  1. Rotate the Gear Rotary Switch to the "ACV" position.
  2. Connect the test leads to the circuit where AC voltagó nílò láti wọn e.
  3. Awọn AC voltage yoo han lori LCD.

6.5 Ìwọ̀n Ìdènà Kéré Jù

For continuity or low resistance checks:

  1. Rotate the Gear Rotary Switch to the "Ω" (low resistance) position.
  2. Connect the test leads to the Resistor jacks.
  3. Connect the other ends of the test leads to the component or circuit to be measured.
  4. The resistance value will be displayed on the LCD.

7. Itọju

7.1 Ninu

Pa ohun elo naa pẹlu ipolowoamp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the instrument is completely dry before storage or next use.

7.2 Ibi ipamọ

When not in use for extended periods, remove the batteries to prevent leakage. Store the instrument in the provided cloth bag in a cool, dry place, away from direct sunlight and extreme temperatures.

  • Ibi ipamọ otutu: -20 ℃ si 60 ℃
  • Working Conditions: 0℃ to 40℃
  • Ọriniinitutu ibatan: 40% si 75%

8. Laasigbotitusita

If you encounter issues with your WOOXGEHM T6125, refer to the following common problems and solutions:

  • Ko si Agbara:
    • Ṣàyẹ̀wò bóyá àwọn bátìrì ti fi sí ibi tí ó yẹ kí ó sì gba agbára tó. Rọ́pò rẹ̀ tí ó bá pọndandan.
    • Ensure the Gear Rotary Switch is not in the "OFF" position.
  • Awọn kika ti ko pe:
    • Verify test leads are securely connected and not damaged.
    • Ensure the correct measurement function and test voltage are selected.
    • Clean the test points on the equipment being measured.
    • Check for external interference sources.
  • "OL" or Over-range Display:
    • The measured value exceeds the selected range. Try a higher test voltage or a different range if applicable.
    • Ensure proper connection to the circuit.

Ti iṣoro naa ba wa, kan si atilẹyin alabara.

9. Awọn pato

Gbogbogbo Awọn alaye
AwoṣeT6125
Ohun eloABS
Ibi ti ina elekitiriki ti nwa8 x 1.5V AA batiri (ko si)
Iwọn Nkan179 x 133 x 70 mm (7.04 x 5.23 x 2.75 in)
Iwọn Nkan570 g (1.25 lb)
Ibi ipamọ otutu-20 ℃ si 60 ℃
Awọn ipo Ṣiṣẹ0 ℃ si 40 ℃
Giga2000m
Ọriniinitutu ibatan40% si 75%

Insulation Test Accuracy (T-6125)

O wujade VoltageIbiti o waIpinnuO pọju igbeyewo LọwọlọwọYiye
250V (± 10%)0 ~ 20MΩ0.01MΩ2mA± (3%+5)
20 ~ 200MΩ0.1MΩ± (3%+5)
0.2G~2GΩ0.001GΩ± (10%+5)
500V (± 10%)0 ~ 20MΩ0.01MΩ2mA± (3%+5)
20 ~ 200MΩ0.1MΩ± (3%+5)
0.2G~2GΩ0.001GΩ± (10%+5)
1000V (± 10%)0 ~ 20MΩ0.01MΩ2mA± (3%+5)
20 ~ 200MΩ0.1MΩ± (3%+5)
0.2G~2GΩ0.001GΩ± (10%+5)
2500V (± 10%)0 ~ 20MΩ0.01MΩ2mA± (3%+5)
20 ~ 200MΩ0.1MΩ± (5%+5)
0.2G~2GΩ0.001GΩ± (10%+5)
2G~20GΩ0.01GΩ± (10%+5)
AC Voltage YiyeRanging: 600VIpinnu: 1VN/A± (1.5%+5)
Yiye ResistanceRanging: 60ΩIpinnu: 0.01ΩN/A± (1.2%+5)
Table showing insulation test accuracy for WOOXGEHM T6125

Figure 5: Detailed insulation test accuracy specifications for the T6125 model.

Dimensions of the WOOXGEHM T6125 Insulation Resistance Tester

Figure 6: Physical dimensions of the WOOXGEHM T6125.

10. Atilẹyin ọja ati Support

For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official WOOXGEHM webojula. Tọju iwe-ẹri rira rẹ bi ẹri rira.

© 2024 WOOXGEHM. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.