SEBSON IR_ES_EA

SEBSON Recessed Ceiling Motion Detector (IR_ES_EA) - Anthracite

Ilana itọnisọna

1. Ifihan

Thank you for choosing the SEBSON Recessed Ceiling Motion Detector. This device is designed for indoor use to automatically control lighting based on motion and ambient light levels. Please read this manual carefully before installation and operation to ensure proper function and safety.

Iwaju view of the SEBSON recessed ceiling motion detector with key specifications overlaid: 8m/360° detection, up to 1000W LED, IP20, 10sec-30min timer, 3-2000 LUX, 230V.
Olusin 1: Pariview of the motion detector and its main features.

2. Awọn ilana aabo

  • Fifi sori gbọdọ jẹ ṣiṣe nipasẹ onisẹ ina mọnamọna ni ibamu pẹlu awọn ilana wiwọ agbegbe.
  • Disconnect power at the main circuit breaker before installation or maintenance.
  • Do not exceed the maximum load capacity of the detector (2000W for incandescent, 1000W for LED).
  • Ọja yii jẹ apẹrẹ fun lilo inu ile nikan. Yago fun ifihan si ọrinrin tabi iwọn otutu to gaju.
  • Rii daju pe fentilesonu to dara ni ayika ẹrọ naa.

3. Awọn ẹya Ọja

  • Indoor motion detector for recessed ceiling mounting.
  • Wide detection range of 8 meters and 360 degrees.
  • Adjustable operating duration from 10 seconds to 30 minutes.
  • Ìmọ́lẹ̀ àyíká tí a lè ṣàtúnṣe láti 3 sí 2000 lux.
  • Compatible with LED lighting (max 1000W) and incandescent bulbs (max 2000W).
  • 3-wire connection for reliable operation.

4. Package Awọn akoonu

  • 1x SEBSON Recessed Ceiling Motion Detector (Anthracite)
  • 1x Ilana itọnisọna

5. fifi sori

Pataki: Ensure power is disconnected at the main circuit breaker before starting installation.

  1. Prepare a mounting hole in the ceiling with a diameter of 63-66 mm. Ensure there is sufficient depth (minimum 45 mm) for the detector.
  2. Connect the wiring according to the diagram below. The detector requires a 3-wire connection (Live, Neutral, Switched Live).
  3. Insert the detector into the prepared hole. The spring clips will secure it in place.
  4. Mu agbara pada ki o si danwo iṣẹ naa.

5.1. Ọja Ipariview ati Awọn iwọn

Iwaju view of the SEBSON recessed ceiling motion detector in anthracite color.
olusin 2: Iwaju view of the motion detector. This image shows the anthracite-colored circular housing with the central infrared sensor dome.
Technical drawing showing the dimensions of the motion detector: 75mm diameter, 42mm height, 60mm internal width, 34mm internal height, 31mm spring length, 3mm bezel thickness.
Figure 3: Detailed dimensions of the motion detector. The overall diameter is 75mm, and the height is 42mm. The mounting hole diameter should be between 63-66mm.
Apa view diagram illustrating the recessed installation, showing a minimum installation depth of 45mm and a ceiling thickness of up to 20mm.
Figure 4: Installation depth requirement. A minimum depth of 45mm is needed for proper recessed mounting.
Ẹyìn view of the motion detector showing the wiring terminal block and spring clips.
olusin 5: Ẹyìn view showing the wiring terminal. This is where the Live, Neutral, and Switched Live wires are connected.

6. Ṣiṣẹ ati Awọn atunṣe

The motion detector features two adjustable dials on the back for 'TIME' (duration) and 'LUX' (light sensitivity).

Ẹyìn view of the motion detector showing the 'TIME' and 'LUX' adjustment dials. The TIME dial ranges from 10s to 30min, and the LUX dial from 3 to 2000 lux.
Figure 6: Adjustment dials for TIME and LUX settings.

6.1. TIME Adjustment

The 'TIME' dial controls how long the connected light remains on after motion is detected and no further motion is sensed. Rotate the dial to set the desired duration:

  • 10s: Minimum duration (10 seconds).
  • 30 min: Maximum duration (30 minutes).

6.2. LUX Adjustment

The 'LUX' dial determines the ambient light level at which the detector will activate. This allows the light to only turn on when it's dark enough.

  • 3: Activates only in very dark conditions (e.g., night).
  • 2000: Activates in all light conditions (day and night).

To set the LUX level, turn the dial to the sun symbol (2000 lux) for testing during daylight. Once satisfied with the detection, adjust the dial towards the moon symbol (3 lux) to the desired ambient light level for automatic operation.

6.3. Ibiti wiwa

Diagram showing the 360-degree detection area of the motion detector, with a maximum range of 8 meters and an installation height between 1.8m and 4m.
Figure 7: Detection range and angle. The detector covers a 360-degree area with a maximum range of 8 meters when installed at a height between 1.8m and 4m.

The detector has a 360° detection angle and a maximum range of 8 meters. Optimal installation height is between 1.8m and 4m. Avoid installing near heat sources, direct sunlight, or areas with significant air movement (e.g., air conditioning vents) to prevent false triggers.

7. Itọju

The SEBSON motion detector requires minimal maintenance. Ensure the sensor lens is kept clean and free from dust or obstructions. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.

8. Laasigbotitusita

Isoro Owun to le Fa Ojutu
Imọlẹ ko tan.
  • Ko si ipese agbara.
  • LUX setting too low (too dark).
  • Ko si išipopada ti a rii laarin iwọn.
  • Aṣiṣe onirin.
  • Check circuit breaker and connections.
  • Adjust LUX dial towards the sun symbol.
  • Ensure motion occurs within the detection zone.
  • Ṣe àyẹ̀wò àwọn ìsopọ̀ onírin.
Imọlẹ duro nigbagbogbo.
  • Iṣipopada ti nlọ lọwọ ni agbegbe idanimọ.
  • TIME setning ti gun ju.
  • Wiring error (e.g., switched live permanently connected).
  • Clear detection zone of constant movement.
  • Ṣàtúnṣe TIME dial sí àkókò kúkúrú.
  • Check wiring for correct connections.
Ìmọ́lẹ̀ máa ń tàn láìsí ìṣípo tí ó hàn gbangba.
  • Heat sources (e.g., heater, direct sunlight).
  • Air currents (e.g., open window, AC vent).
  • Small animals.
  • Relocate detector or remove interfering objects.
  • Ensure stable environment.
  • Adjust sensitivity if possible (this model does not have explicit sensitivity adjustment, but careful placement can help).

9. Awọn pato

Brand SEBSON
Nọmba awoṣe IR_ES_EA
Àwọ̀ Anthracite
Awọn iwọn (L x W x H) 7.5 x 7.5 x 7.5 cm
Iwọn 110 giramu
Iṣagbesori Iru Ijalẹ (Ile)
Iṣagbesori Iho opin 63-66 mm
Orisun agbara AC Agbara
Ẹrù Tó Púpọ̀ Jùlọ (Ìtànṣán) 2000 W
Max Load (LED/Energy Saving) 1000 W
Ibiti wiwa 8 mita
Igun Awari 360°
Operating Duration (TIME) Ìṣẹ́jú-àáyá 10 - ìṣẹ́jú 30
Ambient Light Sensitivity (LUX) 3 - 2000 lux
Awọn ẹrọ ibaramu Basic lighting controls
Niyanju Lilo Residential security, commercial security, automation, energy management
Ilu isenbale China

10. Atilẹyin ọja ati Support

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official SEBSON webojula. Jeki ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.

© 2026 SEBSON. Gbogbo ẹ̀tọ́ wa ni ipamọ́.