1. Ifihan

The sinocare Safe-Accu2 Blood Glucose Meter is designed for self-testing blood glucose levels. This manual provides essential information for the proper use and maintenance of your device. Regular monitoring of blood glucose is crucial for managing diabetes.

The Safe-Accu2 system offers accurate and reliable results with a small blood sample and quick testing time.

sinocare Safe-Accu2 Blood Glucose Meter with a person giving a thumbs up, indicating accuracy.

Image: The sinocare Safe-Accu2 Blood Glucose Meter, highlighting its accuracy and reliability.

2. Ohun ti o wa ninu Apoti

Your sinocare Safe-Accu2 Blood Glucose Monitoring System kit typically includes the following components:

  • sinocare Safe-Accu2 Blood Glucose Meter
  • Test Strips (quantity may vary by kit, e.g., 50 strips)
  • Ẹrọ Lancing
  • Lancets (quantity may vary by kit, e.g., 50 lancets)
  • Ọran gbigbe
  • Itọsọna olumulo
Contents of the sinocare Safe-Accu2 Blood Glucose Meter kit, including the meter, test strips, lancing device, and carrying case.

Aworan: Pariview of the sinocare Safe-Accu2 Blood Glucose Meter kit components.

Alaye view of the sinocare Safe-Accu2 kit showing the meter, lancing device, test strip vials, and lancets.

Aworan: Alaye view of the sinocare Safe-Accu2 50-set kit components.

3. Ọja Ipariview

The sinocare Safe-Accu2 meter features a large, clear display and intuitive controls for ease of use. Key features include:

  • Ko nilo koodu: Test strips are automatically calibrated.
  • Awọn esi Yara: Provides blood glucose readings in approximately 10 seconds.
  • Kekere Sample Iwon: Requires only 0.6 microliters of blood.
  • Agbara iranti: Stores up to 200 test results with date and time, including 7, 14, and 30-day averages.
  • Awọn Atọka Imọlẹ: Red and green indicator lights provide immediate feedback on blood sugar levels.
Diagram illustrating the features of the sinocare Safe-Accu2 meter: Easy (No Code), Accurate (SOD Chip), Large (Larger Screen, More Clearly), Stable (4PIN & 3-electrode), Clear (Light indicates blood sugar level), Record (Time display), Little (0.6 Micro Liters), Wide (Red Blood Cell), Quick (10s Testing Time), Light (Portable to carry).

Image: Key features and design elements of the Safe-Accu2 meter.

Labeled diagram of the sinocare Safe-Accu2 meter and lancing device, showing the strip ejection button, test value display, date & time, red and green indicator lights, ON/OFF button, power button functions, time setting program, decrease/page down button, battery case, and details of the test strip and lancing device.

Image: Detailed diagram of the meter's components and controls.

4. Ni ibẹrẹ Oṣo

4.1. Fifi sori batiri

The Safe-Accu2 meter uses 2*AAA Alkaline batteries. Open the battery compartment on the back of the device and insert the batteries according to the polarity indicators. Close the compartment securely.

4.2. Eto Ọjọ ati Aago

Upon first use or after battery replacement, you may need to set the date and time. Refer to the "Power Button" functions in the product overview diagram. Typically, pressing and holding the power button allows entry into the time setting program. Use the arrow buttons to adjust values and the power button to confirm.

5. Àwọn Ìlànà Ìṣiṣẹ́: Ṣíṣe Àyẹ̀wò Gúkósì Ẹ̀jẹ̀

  1. Mura Ẹrọ Lancing:
    • Unscrew the cap of the lancing device.
    • Insert a new, sterile lancet firmly into the lancet holder.
    • Twist off the protective cap from the lancet.
    • Replace the lancing device cap.
    • Adjust the penetration depth by rotating the cap (settings 1-9, 3 is often suitable for average skin).
    • Pull back the cocking barrel until it clicks, indicating it's ready to use.
    Image showing the lancing device with adjustable depth settings and a diagram of how to dispose of used test strips.

    Image: Lancing device with adjustable depth and strip disposal mechanism.

  2. Insert a Test Strip:

    Insert a sinocare Accu-2 test strip into the meter's test strip port. The meter will automatically turn on and display a blood drop symbol, indicating it's ready for a blood sample. The meter does not require manual coding.

    Four-step instruction image for blood glucose testing: 1. Insert sinocare Accu-2 test strip. 2. Collect blood samples by Painfree lancing device. 3. Take blood sample from the top of sinocare Accu-2 test strip. 4. Test result in 10 seconds.

    Image: Step-by-step guide for performing a blood glucose test.

  3. Gba Ẹjẹ Sample:

    Place the lancing device firmly against the side of your fingertip and press the release button. A small drop of blood will form. Gently squeeze your finger if necessary to obtain a sufficient sample (0.6 µL).

  4. Apply Blood to the Test Strip:

    Touch the tip of the test strip to the blood drop. The blood will be drawn into the strip automatically. Do not apply blood to the top of the strip. The meter will beep and begin counting down.

  5. Read the Result:

    After approximately 10 seconds, your blood glucose result will appear on the display. The meter will also show a red or green light indicator:

    • Imọlẹ pupa: Blood sugar level ≤3.9mmol/L (low blood sugar) or blood sugar level ≥13.9mmol/L (high blood sugar). Consult a healthcare professional.
    • Imọlẹ alawọ ewe: Blood sugar level >3.9mmol/L and <13.9mmol/L (normal blood sugar).
    Diagram explaining the red and green light prompts on the sinocare Safe-Accu2 meter, indicating low, normal, or high blood sugar levels. Also includes a specification table.

    Image: Light prompt indicators for blood glucose levels.

  6. Dispose of Used Materials:

    Eject the used test strip from the meter using the strip ejection button. Carefully remove the used lancet from the lancing device and dispose of both safely in a sharps container or according to local regulations.

Important Notice for Accurate Results:

  • The operation of measuring blood sugar is best completed within 3 minutes.
  • After the test strip bottle is opened, the test strips inside need to be used up within 6 months.

6. Itọju ati Ipamọ

6.1. Cleaning the Meter

Mu ese ita mita naa pẹlu asọ, damp cloth. Do not immerse the meter in water or use harsh cleaning agents. Ensure no liquid enters the test strip port.

6.2. Ibi ipamọ

  • Store the meter and test strips in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Keep test strip vials tightly closed after removing a strip.
  • Meter storage conditions: -20°C ~ 55°C.
  • Operating conditions: 10°C ~ 35°C (≤80%RH).

7. Laasigbotitusita

IsoroOwun to le FaOjutu
Meter does not turn on.Awọn batiri ti o ku tabi ti ko tọ fi sii.Check battery orientation. Replace batteries if necessary.
Ifiranṣẹ aṣiṣe han.Improper test strip insertion, insufficient blood sample, or damaged strip.Ensure strip is inserted correctly. Re-test with a new strip and sufficient blood. Refer to the full manual for specific error codes.
Àwọn àbájáde tí kò báradé mu.Expired test strips, improper storage, or incorrect testing procedure.Check strip expiry date. Ensure strips are stored correctly. Review testing steps carefully. Consult a healthcare professional if concerns persist.
Lancing device does not prick.Not cocked, or lancet not inserted correctly.Ensure the lancing device is cocked. Check that a new lancet is inserted firmly.

For further assistance, please refer to the complete user manual or contact sinocare customer support.

8. Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
EtoFAD-GDH
Blood Volume0.6µL
Sample IruOdidi ẹjẹ capillary, Odidi ẹjẹ Venous
IsọdiwọnẸtọ Plasma
Akoko Idanwo10 aaya
Meter Storage Conditions-20°C ~ 55°C
Awọn ipo iṣẹ10°C ~ 35°C (≤80%RH)
HCT (Hematocrit)30% - 60%
Igbeyewo Ibiti1.1 - 33.3 mmol/L
Iranti200 test results with date & time
Batiri2*AAA Alkaline batteries

Akiyesi: Awọn alaye ni o wa labẹ iyipada laisi akiyesi.

9. Alaye Aabo pataki

  • Ẹrọ yii jẹ ipinnu fun in vitro diagnostic use only. Do not use for diagnosis of diabetes, but as an aid in monitoring diabetes management.
  • Consult your healthcare professional before making any changes to your medication, diet, or exercise program based on your blood glucose results.
  • Keep the meter, test strips, and lancets out of reach of children.
  • Always use fresh, sterile lancets and unexpired test strips.
  • Dispose of used lancets and test strips properly in a puncture-resistant container to prevent injury and infection.
  • Do not use the meter if it appears damaged or is not functioning correctly.
  • The system is indicated for monitoring blood glucose, including diabetes control.

10. Atilẹyin ọja ati Support

For warranty information, please refer to the documentation included with your product or contact sinocare customer service. sinocare is committed to providing satisfactory after-sales service.

For video user guidance, you may visit the following external resource: sinocare Safe-Accu2 Video Guide.

If you require a PDF manual in other languages, please contact sinocare customer support through Amazon or their official channels.

© 2025 sinocare. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.