waveshare UPS Power Module (C)

Waveshare UPS Power Module (C) for Jetson Orin - Instruction Manual

1. Ifihan

This manual provides detailed instructions for the installation, operation, and maintenance of the Waveshare UPS Power Module (C). This module is designed to provide uninterruptible power to Jetson Orin series boards, ensuring stable operation and data integrity during power fluctuations or outages. It supports three 21700 Li-ion batteries (not included) and features real-time battery monitoring via I2C communication.

2. Akoonu Package

Daju pe gbogbo awọn nkan ti a ṣe akojọ rẹ si isalẹ wa ninu package rẹ:

Image showing the Waveshare UPS Power Module (C) and its included accessories: acrylic protection panel, DC dual-plug cable, and screws pack.

Figure 2.1: Included components of the Waveshare UPS Power Module (C) package.

  • UPS Power Module (C) x1
  • Acrylic protection panel x1
  • DC dual-plug cable x1
  • Àpò àwọn skru x1

Note: Three 21700 Li-ion batteries (9V-12.6V) are NOT included and must be purchased separately.

3. Awọn iṣọra aabo

Please read and adhere to the following safety guidelines to prevent personal injury or damage to the product:

Image displaying the Waveshare UPS Power Module (C) with a prominent 'SAFETY CAUTIONS' box listing warnings regarding battery handling.

Figure 3.1: Important safety cautions for battery handling and module usage.

  • Li-ion and Li-Po batteries are inherently unstable. Improper recharging or usage may lead to fire, personal injury, or property damage.
  • Maṣe ṣe reverse battery polarities during recharging or discharging.
  • Maṣe ṣe use inferior chargers or charging panels.
  • Maṣe ṣe mix old batteries with new ones, or use batteries from different brands.
  • Nigbati riraasing Lithium batteries, ensure their specifications are compatible with this expansion board. Use batteries from reputable manufacturers that have passed aging tests for stability and safety.
  • Lithium batteries have a limited cycle life. Replace them when they reach their maximum cycle life or after two years, whichever comes first.
  • Handle the module and batteries carefully. Keep them away from flammable and explosive materials. Store away from children to prevent accidents.

4. Awọn ẹya ara ẹrọ

The Waveshare UPS Power Module (C) offers the following key features:

Image detailing the features and specifications of the Waveshare UPS Power Module (C).

Olusin 4.1: Pariview of module features and specifications.

  • Supports simultaneous charging and power output.
  • Batiri voltage monitoring via I2C bus communication.
  • Pogo pins connector design, ensuring compatibility with Jetson Orin series boards.
  • Onboard Li battery charging chip with dynamic path management for a stable power supply.
  • Multi-battery protection circuits: over charge/discharge, over current, short circuit.
  • Equalizing charge feature and battery reverse indicators for enhanced safety and stability.
  • Supports three 21700 batteries (not included) for extended battery life.

5. Awọn pato

ParamitaIye
O wujade VoltageKanna bi input voltage when power is present; equals battery voltage (9V-12.6V) when no power input.
Iṣagbewọle Voltage15V~19V
Bus IṣakosoI2C
Awọn iwọn100 × 79 mm
Atilẹyin batiri21700 Li-ion Battery × 3 (in series, NOT included)
Iṣagbesori Iho Iwon2.5mm
Ohun eloṢiṣu
Àwọ̀Dudu
Iwọn Nkan0.12 kilo
Asopọmọra IruPogo Pinni

6. Eto ati fifi sori

6.1. Fifi sori batiri

Insert three 21700 Li-ion batteries (not included) into the battery holders on the module. Ensure correct polarity by matching the '+' and '-' markings on the batteries with those on the module. Incorrect insertion will trigger the battery reverse indicators.

6.2. Module Mounting

Image showing the Waveshare UPS Power Module (C) mounted on a Jetson Orin Nano and a Jetson Orin NX board, demonstrating product compatibility.

Figure 6.1: UPS Power Module (C) compatibility with Jetson Orin Nano and Jetson Orin NX.

Align the UPS Power Module (C) with the pogo pins on your Jetson Orin Nano or Jetson Orin NX board. Gently press down to ensure the pogo pins make proper contact. Secure the module to the Jetson board using the provided screws and standoffs. The mounting holes are designed for precise alignment.

Close-up image of the Waveshare UPS Power Module (C) highlighting the pogo pins connector and various input/output ports and indicators.

Figure 6.2: Pogo Pins Connector and module interfaces.

6.3. Acrylic Protection Panel

Attach the acrylic protection panel to the module using the remaining screws. This panel provides physical protection for the module's circuitry.

6.4. Asopọ agbara

Connect the provided DC dual-plug cable to the module's 15V-19V input port. Connect the other end of the cable to a compatible 15V-19V power adapter (not included).

7. Isẹ

7.1. Agbara Tan / Paa

Use the onboard system power button to turn the module and the connected Jetson board on or off. A short press typically powers on, and a long press initiates a shutdown sequence.

7.2. Charging and Power Output

Image showing the UPS Power Module (C) connected to a Jetson Orin board and a display, illustrating uninterruptible power and real-time monitoring.

Figure 7.1: Uninterruptible power and real-time monitoring in action.

When an external power supply (15V-19V) is connected, the module will charge the installed 21700 batteries. The charge indicator LED will illuminate during this process. The module simultaneously provides power to the Jetson board. If external power is lost, the module automatically switches to battery power, ensuring continuous operation without interruption.

7.3. Awọn itọkasi

  • Atọka idiyele: Illuminates when batteries are actively charging.
  • Atọka gbigba agbara ni kikun: Illuminates when batteries are fully charged.
  • Atọka eto: Indicates the operational status of the system.
  • Battery Reverse Indicators: Light up red if a battery is inserted with incorrect polarity.

8. Dynamic Path Management

Diagram illustrating the dynamic path management system, showing power input, recharger chip, Li battery, and system power consumption flow.

Figure 8.1: Dynamic Path Management System Diagram.

The module incorporates dynamic path management for efficient power delivery. When an external power supply (15V-19V) is connected, the battery output is disconnected. The system is powered directly by the external supply, and the installed batteries are charged simultaneously with a maximum charging current of approximately 1.33A.

Battery charging automatically stops once fully charged and resumes if the battery voltage drops below 12V. This intelligent charging mechanism prevents damage to the batteries from frequent charging and discharging cycles. If the external power supply becomes unavailable, the system seamlessly switches to battery power, ensuring continuous operation without interruption.

9. Real-Time Abojuto

The UPS Power Module (C) utilizes I2C bus communication to monitor critical battery parameters in real-time, including voltage, current, power, and remaining capacity. This data can be accessed by the connected Jetson Orin board.

In scenarios where the battery voltage drops below a critical threshold, the system can be configured via software on the Jetson board to automatically save any open files and initiate a graceful shutdown. This feature helps prevent data loss during unexpected power outages.

When monitoring current, a negative value indicates that the batteries are discharging (powering the system), while a positive value indicates that the batteries are recharging.

10. Safe and Stable Circuit Design

Alaye view of the Waveshare UPS Power Module (C) circuit board, highlighting various protection circuits, charging circuit, and monitoring components.

Figure 10.1: Internal circuit design with protection features.

The module is engineered with multiple protection circuits to ensure safe and stable operation. These include:

  • Idaabobo overcharge: Dínà kí àwọn bátìrì má gba agbára ju agbára wọn lọtage iye to.
  • Idaabobo Isọjade ju: Prevents batteries from being discharged below their safe voltage limit, prolonging battery life.
  • Idaabobo lọwọlọwọ: Awọn aabo lodi si iyaworan lọwọlọwọ ti o pọju.
  • Idaabobo Circuit Kukuru: Laifọwọyi ge agbara kuro ni ọran ti Circuit kukuru kan.
  • Equalizing Charge Feature: Awọn iwọntunwọnsi awọn voltage across the three series-connected 21700 batteries, which helps extend their overall lifespan and performance.
  • Battery Reverse Indicators: Visual alerts (red LEDs) if a battery is inserted with incorrect polarity, preventing immediate damage.

11. Pin Definition and Outline Dimensions

Image showing the pin definitions for the I2C communication and the outline dimensions of the Waveshare UPS Power Module (C) in millimeters.

Figure 11.1: Pin definitions and physical dimensions of the module.

11.1. Pin Definition

The I2C communication pins are defined as follows:

  • GND: Ilẹ
  • 3V3: 3.3V agbara igbewọle
  • SDA: Monitoring chip Serial Data line
  • SCL: Monitoring chip Serial Clock line

11.2. Outline Dimensions

The physical dimensions of the UPS Power Module (C) are:

  • Gigun: 100.00 mm
  • Ìbú: 79.00 mm
  • Mounting Hole Spacing (Horizontal): 86.00 mm
  • Mounting Hole Spacing (Vertical): 58.00 mm

12. Itọju

12.1. Itọju batiri

Regularly inspect the 21700 batteries for any signs of damage or swelling. Replace batteries that show signs of wear or have reached their end-of-life cycle (typically after two years or a specified number of charge cycles).

12.2. Ninu

Keep the module free from dust and debris. Use a soft, dry cloth to gently clean the surface. Avoid using liquids, solvents, or abrasive cleaners, as these can damage the electronic components.

12.3. Ibi ipamọ

If the module will not be used for an extended period, remove the 21700 batteries and store them separately in a cool, dry place, away from direct sunlight and extreme temperatures. Store the module in its original packaging or an anti-static bag.

13. Laasigbotitusita

13.1. Module Not Powering On

  • Ṣayẹwo fifi sori batiri: Ensure all three 21700 batteries are correctly installed with proper polarity.
  • Jẹrisi idiyele Batiri: Confirm that the batteries are sufficiently charged.
  • Ipese Agbara Ita: Ensure the 15V-19V external power supply is connected and functional.
  • Pogo Pin Connection: Check that the module is securely connected to the Jetson board via the pogo pins.

13.2. Batteries Not Charging

  • Ipese Agbara Ita: Confirm the external power supply is connected and providing 15V-19V.
  • Atọka idiyele: Check if the charge indicator LED is illuminated. If not, there might be an issue with the power input or battery connection.
  • Ilera Batiri: Verify the health and proper insertion of the batteries.

13.3. I2C Monitoring Data Incorrect or Unavailable

  • Ìsopọ̀ I2C: Ensure the pogo pin connection for I2C communication between the module and Jetson board is secure.
  • Iṣeto ni Sọfitiwia: Verify that the I2C communication is correctly configured in the Jetson board's operating system or application.

13.4. Battery Reverse Indicator On

  • Iṣe Lẹsẹkẹsẹ: Immediately power off the module and correct the battery polarity. Operating with reversed batteries can cause damage.

14. Atilẹyin ọja ati Support

14.1. atilẹyin ọja Information

This Waveshare UPS Power Module (C) is covered by a 1-year manufacturer's warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by misuse, accidents, unauthorized modifications, or improper installation.

14.2. Imọ Support

For additional resources, detailed documentation, software examples, or technical assistance, please refer to the official Waveshare Wiki resources. The Wiki often contains comprehensive guides and community support. Contact information for direct technical support can typically be found on the official Waveshare webojula.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.