OQIMAX 060d063b-d1db-4484-bfc8-33ec02acf94a

OQIMAX Wireless Refrigerator Thermometer with Freezer Alarm

Model: 060d063b-d1db-4484-bfc8-33ec02acf94a

Brand: OQIMAX

Ọrọ Iṣaaju

Thank you for choosing the OQIMAX Wireless Refrigerator Thermometer. This device provides real-time temperature monitoring for your refrigerator and freezer compartments, helping you maintain optimal food storage conditions. It features a clear LCD display, adjustable alarms, and historical temperature recording. Please read this manual carefully before use to ensure proper operation and longevity of your device.

Package Awọn akoonu

  • 1 x Temperature Station (Main Unit)
  • 1 x Freezer Sensor
  • 1 x Refrigerator Sensor
  • 1 x Itọsọna olumulo
Image showing the OQIMAX Wireless Refrigerator Thermometer package contents: main display unit, two remote sensors, and a user manual.

The package includes the main display unit, two remote sensors (one for freezer, one for refrigerator), and the instruction manual.

Ọja Awọn ẹya ara ẹrọ

  • Iboju LCD HD: A 3.7-inch display clearly shows real-time temperatures, MAX/MIN values, and alarm indicators.
  • Abojuto ikanni meji: Simultaneously monitors temperatures for both freezer and refrigerator compartments.
  • Adjustable Upper/Lower Limit Alarms: Set custom temperature ranges. Alarms activate with flashing icons and audible alerts if temperatures exceed or fall below the set limits. Features a 2-minute delay to prevent false alarms from temporary door openings.
  • MAX/MIN Temperature Record: Records maximum and minimum temperature values for the last 24 hours or all-time, allowing you to track temperature fluctuations. These records can be cleared.
  • Iṣẹ ina ẹhin: Fun irọrun viewing in low-light conditions. The backlight automatically turns off after 10 seconds to conserve battery life.
  • °C/F Yipada: Easily switch between Celsius and Fahrenheit temperature units.
  • Fifi sori Rọrun: The main unit can be placed upright or hung. Sensors come with hooks for convenient placement inside compartments.
  • IPX4 Splash-proof Sensors: Designed to withstand splashes from any direction.
Diagram illustrating key features of the OQIMAX thermometer: Dual-channel, °C/°F Switch, All time/24 HR record, Temperature Alarm, MAX/MIN Record, 10S Backlight, Delay alarms, and Detachable Hook.

Pariview of the main features including dual-channel monitoring, temperature unit switch, historical records, alarms, backlight, and detachable hooks for sensors.

Ṣeto

1. Fifi sori batiri

  • Ẹka akọkọ: Open the battery compartment on the back of the main unit. Insert 3 x AAA (LR03) 1.5V batteries, ensuring correct polarity. Close the compartment.
  • Awọn sensọ: Open the battery compartment on each remote sensor. Insert 2 x AAA (LR03) 1.5V batteries into each sensor, ensuring correct polarity. Close the compartments.

2. Pairing the Sensors

  1. After installing batteries in the main unit, the freezer and refrigerator signal icons will flash, indicating it is ready to receive external signals.
  2. For each sensor, press the TX button (located inside the battery compartment or on the back) for immediate signal transmission. The main unit will display the temperature from the sensor once paired.
  3. If pairing does not occur immediately, wait for approximately 30 seconds for the detection cycle to complete. If still unsuccessful, long-press the RF/- button on the main unit to re-pair.

3. Ibi sensọ

  • Place the freezer sensor (labeled "FREEZER") inside your freezer compartment.
  • Place the refrigerator sensor (labeled "REFRIGERATOR") inside your refrigerator compartment.
  • Both sensors are equipped with hooks for easy hanging on shelves or racks, optimizing space.
  • Position the main unit outside the refrigerator/freezer in a convenient location where you can easily read the display. It can stand upright or be hung.
Image showing the back of the main unit with battery compartment and stand, and the back of a sensor with battery compartment and detachable hook. Text indicates 3xAAA for main unit and 2xAAA for sensors.

Illustration of battery installation and placement options for the main unit and sensors.

Image showing the main display unit placed on the exterior of a refrigerator door, with a remote sensor hanging inside the refrigerator compartment among food items.

Example of main unit placement on the refrigerator exterior and a sensor placed inside.

Awọn ilana Iṣiṣẹ

Ifihan Loriview

Diagram labeling parts of the LCD display: Freezer temperature, Refrigerator temperature, Freezer alarm icon, Refrigerator alarm icon, Freezer MIN/MAX temperature values, Refrigerator MIN/MAX temperature values.

Understanding the information displayed on the main unit's LCD screen.

  • The top left shows the current freezer temperature.
  • The top right shows the current refrigerator temperature.
  • Below each current temperature, the MIN and MAX recorded temperatures are displayed.
  • Alarm icons (bell with ON/OFF) indicate alarm status for each compartment.

Awọn iṣẹ bọtini

BọtiniKukuru Tẹ IšėGun Tẹ Išė
FREEZE SETToggle freezer alarm ON/OFF.Set freezer alarm temperature.
CLE/+Select between 24-hour and All-time historical modes.Clear historical MAX/MIN records.
RF/-Display the set alarm value.Re-pair sensors.
COOL SETToggle refrigerator alarm ON/OFF.Set refrigerator alarm temperature.
° C / ° FSwitch between Celsius (°C) and Fahrenheit (°F).N/A

Eto Awọn itaniji

  1. Freezer Alarm: Gun tẹ awọn FREEZE SET button. The freezer alarm temperature will start flashing. Use the CLE/+ ati RF/- buttons to adjust the desired upper and lower limits. Short press FREEZE SET again to confirm and exit setting mode.
  2. Refrigerator Alarm: Gun tẹ awọn COOL SET button. The refrigerator alarm temperature will start flashing. Use the CLE/+ ati RF/- buttons to adjust the desired upper and lower limits. Short press COOL SET again to confirm and exit setting mode.
  3. Láti mu/mu itaniji ṣiṣẹ, tẹ ni kukuru ti o baamu FREEZE SET or COOL SET button. An "ON" or "OFF" indicator will appear next to the alarm icon.
  4. Akiyesi: Alarms have a 2-minute delay to prevent false triggers from brief temperature changes (e.g., opening the door).
Image showing the main display unit with an alarm icon flashing and 'ON' indicator, demonstrating the upper/lower limit alarm feature. Food items are shown in the background.

The display indicates when an alarm is active and the temperature is outside the set limits.

Viewing and Clearing MAX/MIN Records

  • Kukuru tẹ awọn CLE/+ button to cycle between 24-hour and All-time MAX/MIN records.
  • To clear the displayed historical records, long press the CLE/+ bọtini.

Imọlẹ ẹhin

The backlight automatically activates when a button is pressed and turns off after 10 seconds of inactivity to save power.

Itoju

Batiri Rirọpo

When the battery indicator appears on the display, replace the batteries in the main unit or the respective sensor. Always use new AAA (LR03) 1.5V batteries and ensure correct polarity.

Ninu

Mu ese akọkọ ati awọn sensosi nu pẹlu asọ, damp cloth. Do not use abrasive cleaners or immerse the main unit in water. The sensors are IPX4 splash-proof but should not be submerged.

Ibi ipamọ

If storing the device for an extended period, remove all batteries to prevent leakage and damage.

Laasigbotitusita

IsoroOwun to le FaOjutu
Ko si ifihan lori akọkọ kuro.Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ.Replace batteries (3xAAA) in the main unit, ensuring correct polarity.
Sensor temperature not displayed or shows "--".
  • 1. Dead or incorrectly installed sensor batteries.
  • 2. Sensor out of range.
  • 3. Pairing failed.
  • 1. Replace batteries (2xAAA) in the sensor, ensuring correct polarity.
  • 2. Move the sensor closer to the main unit. Max range is 80m in open field, less with obstacles.
  • 3. Gun tẹ awọn RF/- button on the main unit to re-pair.
Itaniji n dun nigbagbogbo.Alarm limits set too close to operating temperature, or frequent door openings.Adjust alarm limits to a wider range. Remember the 2-minute delay helps prevent false alarms.
Awọn kika iwọn otutu ti ko pe.Sensor placed too close to cooling vents or heat sources.Relocate the sensor to a more central area within the compartment, away from direct airflow or heat.

Awọn pato

Main Unit Mefa9.5 x 8 x 2 cm (3.75 x 3.15 x 0.79 inches)
Main Unit Power3 x AAA (LR03) 1.5V batteries (not included)
Sensor Mefa6 x 7.5 x 2 cm (2.36 x 2.95 x 0.79 inches)
Sensor Hook Length3 cm (1.2 inches)
Agbara Sensọ2 x AAA (LR03) 1.5V batteries per sensor (not included)
Iwọn Iwọn Iwọn otutu-40°C ~ 37.7°C (-40°F ~ 100°F)
Freezer Alarm Setting Range-40°C ~ 0°C (-40°F ~ 32°F)
Refrigerator Alarm Setting Range0°C ~ 15°C (32°F ~ 59°F)
Yiye iwọn otutu± 1°C (± 1.8°F)
Ipinnu0.1°C (0.1°F)
Idaabobo iteIPX4 (Splash-proof from all directions)
Igbohunsafẹfẹ gbigbe433 MHz
Alailowaya IbitiUp to 80m / 26 ft (in open field)
Data Transmission CycleGbogbo 30 aaya
Akoko Idaduro Itaniji2 iṣẹju
Image showing the main display unit and a remote sensor with their dimensions labeled in inches and centimeters.

Detailed dimensions of the main unit and remote sensors.

Atilẹyin ọja ati Support

OQIMAX products are designed for reliability and performance. For any questions, technical support, or warranty inquiries, please contact your retailer or OQIMAX customer service through the contact information provided at the point of purchase. Please retain your proof of purchase for warranty claims.