Cisa 111721602N7

CISA Electric Lock 111721602N7 - Entrata 60 Adjustable Left-Hand Instruction Manual

Model: 111721602N7 | Brand: CISA

1. Ifihan

This manual provides detailed instructions for the installation, operation, and maintenance of your CISA Electric Lock, model 111721602N7. This electric lock is designed for secure access control on gates and doors, offering both key and electric remote opening capabilities. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Alaye Aabo

  • Rí i dájú pé a ti ge ina agbara kuro kí a tó ṣe ìfisí tàbí ìtọ́jú èyíkéyìí.
  • Installation should be performed by qualified personnel to prevent damage or injury.
  • Use only the specified 12V AC power supply. Incorrect voltage can damage the lock.
  • Keep keys and remote controls out of reach of children.
  • Regularly inspect the lock for signs of wear or damage. Do not use if damaged.

3. Package Awọn akoonu

Jẹrisi pe gbogbo awọn paati wa ninu package:

  • CISA Electric Lock unit (Model 111721602N7)
  • Idasesile awo
  • Awọn bọtini
  • Electric remote control mechanism
  • Iṣagbesori skru ati hardware
  • Ilana Afowoyi (iwe yii)

4. Ọja Ipariview

The CISA Electric Lock 111721602N7 is a robust, surface-mounted electric lock constructed from painted aluminum gray steel. It features a self-locking latch and an adjustable backset for versatile installation.

CISA Electric Lock 111721602N7 main view

Nọmba 4.1: Akọkọ view of the CISA Electric Lock 111721602N7, showing the lock body and strike plate.

Iwaju view of CISA Electric Lock

Nọmba 4.2: Iwaju view of the CISA electric lock, highlighting the key cylinder and latch mechanism.

Apa view of CISA Electric Lock

Nọmba 4.3: Apa view of the CISA electric lock, showing its profile àti àkọlé ìfìsípò.

Pada view of CISA Electric Lock with cylinder

Nọmba 4.4: Pada view of the CISA electric lock, illustrating the internal cylinder and wiring access points.

CISA Electric Lock and strike plate separated

Nọmba 4.5: The CISA electric lock unit separated from its strike plate, showing individual components.

5. Eto ati fifi sori

This CISA electric lock is designed for surface mounting on gates and doors. The backset is adjustable from 50mm to 80mm. This specific model (111721602N7) is configured for left-hand doors.

5.1. Determining Door Handing

Stand on the exterior side of the door. If the hinges are on the left, it is a left-hand door. If the hinges are on the right, it is a right-hand door. This lock is a left-hand version.

5.2. Backset Adjustment

The backset (distance from the edge of the door to the center of the key cylinder) can be adjusted to 50mm, 60mm, 70mm, or 80mm. Refer to the technical drawing for adjustment points and ensure the correct backset is set before final installation.

Technical drawing with dimensions for CISA Electric Lock

Nọmba 5.1: Technical drawing showing dimensions and adjustable backset (50-80mm) for the CISA electric lock. This diagram is essential for precise installation and drilling.

5.3. Mounting the Lock Unit

  1. Position the lock unit on the door frame or gate, ensuring it aligns with the strike plate's intended position. Mark the drilling points for the mounting screws and the key cylinder.
  2. Drill pilot holes for the mounting screws and the necessary opening for the key cylinder according to the technical drawing (Figure 5.1).
  3. Secure the lock unit to the door/gate using the provided screws.

5.4. Mounting the Strike Plate

  1. Align the strike plate with the lock's latch mechanism on the opposing frame/post. Ensure smooth engagement of the latch. Mark drilling points.
  2. Drill pilot holes and secure the strike plate with the provided screws.

5.5. Asopọ Itanna

  • Connect the lock to a 12V AC CE power supply. Refer to the wiring diagram (if provided separately or on the unit itself) for correct polarity.
  • Ensure all electrical connections are secure and insulated to prevent short circuits or electrical hazards.
  • Test the electric opening function before finalizing the installation.

6. Awọn ilana Iṣiṣẹ

6.1. Opening from the Exterior

  • Insert the key into the exterior cylinder.
  • Turn the key to retract the latch.
  • Open the door/gate.

6.2. Opening from the Interior

  • Lilo bọtini: Insert the key into the interior cylinder and turn to retract the latch.
  • Using Electric Control: Activate the electric remote control (e.g., push button, intercom system) connected to the lock. The latch will retract, allowing the door/gate to open.

6.3. Titiipa

The CISA electric lock features a self-locking latch. When the door/gate is closed, the latch automatically extends and locks into the strike plate, securing the entry.

7. Itọju

  • Ninu: Clean the exterior of the lock with a soft, damp asọ. Yago fun abrasive ose tabi epo.
  • Lubrication: Periodically apply a small amount of graphite-based lubricant to the key cylinder and moving parts of the latch mechanism to ensure smooth operation. Do not use oil-based lubricants as they can attract dirt.
  • Ayewo: Regularly check all mounting screws for tightness. Inspect the wiring for any signs of wear or damage. Ensure the strike plate is securely fastened and properly aligned.

8. Laasigbotitusita

IsoroOwun to le FaOjutu
Lock does not open electrically.No power, faulty wiring, damaged solenoid.Check power supply. Inspect wiring connections. Consult a qualified technician if solenoid is suspected.
Key turns but latch does not retract.Worn key, internal mechanism obstruction, misaligned cylinder.Try a spare key. Lubricate the cylinder. Check for obstructions. Realign cylinder if necessary.
Latch does not engage strike plate properly.Misalignment of lock and strike plate, loose mounting.Adjust the position of the lock or strike plate. Tighten all mounting screws.
Lock operates stiffly.Lack of lubrication, dirt accumulation.Clean and lubricate the key cylinder and latch mechanism.

9. Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Nọmba awoṣe111721602N7
BrandCISA
IruElectric Lock (Surface Mounted)
Ohun eloAlloy Steel (Painted Aluminum Gray)
Awọn iwọn (L x W x H)11.6 x 12.4 x 17.9 cm (4.57 x 4.88 x 7.05 inches)
Iwọn1.85 kg (4.08 lbs)
Backset (Entrata)Adjustable: 50mm, 60mm, 70mm, 80mm (This model is Entrata 60)
GbigbeOsi-Ọwọ
Ibi ti ina elekitiriki ti nwa12V AC CE
Pataki Awọn ẹya ara ẹrọRemote Control Capability, Self-locking Latch
Iṣeduro LiloGates and doors of houses or properties
Awọn irinše to waKeys, Electric Remote Control Mechanism

10. atilẹyin ọja Information

CISA products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official CISA webojula. Jeki ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.

11. Onibara Support

If you encounter any issues or have questions regarding your CISA Electric Lock 111721602N7 that are not covered in this manual, please contact CISA customer support or your authorized dealer. You can find contact information on the official CISA webojula:

www.cisa.com

© 2023 CISA. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.