The ANENG SZ308 is a versatile digital multimeter designed for accurate and reliable electrical measurements. It is suitable for a wide range of applications, from household electrical checks to automotive diagnostics and industrial maintenance. This manual provides essential information for setting up, operating, and maintaining your device safely and efficiently.
1.1 Abo Alaye
WARNING: Always read and understand all safety warnings and operating instructions before using this instrument. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Maṣe kọja iwọn ti o pọjutage or current ratings specified for the multimeter.
- Ensure test leads are properly connected and in good condition before each use.
- Never use the multimeter on circuits with voltages kọja 1000V DC tabi 750V AC.
- Always turn off power to the circuit and discharge high-voltagàwọn capacitors kí wọ́n tó wọn resistance, continuity, tàbí diode.
- Replace the battery when the low battery indicator appears to ensure accurate readings.
- Má ṣe lo multimeter náà bí ó bá dàbí pé ó ti bàjẹ́ tàbí tí àpótí náà bá ṣí sílẹ̀.
2. Ọja Ipariview
The ANENG SZ308 Digital Multimeter is a compact and lightweight device, making it highly portable for various tasks.

olusin 2.1: Iwaju view of the ANENG SZ308 Digital Multimeter.
2.1 Multimeter Components

Figure 2.2: Diagram illustrating the main panel functions of the ANENG SZ308.
- Iboju LCD: Displays measurement values, units, and function indicators.
- Ṣiṣe ipe iṣẹ: Rotary switch to select measurement modes (Voltage, Current, Resistance, Diode, Continuity, hFE, Square Wave).
- Awọn Jacks ti nwọle: Ports for connecting test leads (VΩmA, COM, 10A).
- hFE Jack: Socket for transistor testing.
- Atọka Batiri Kekere: Icon on the LCD screen indicating low battery power.
- Idaduro data: Button to freeze the current reading on the display.
- Imọlẹ ẹhin: Button to activate the display backlight for use in dim conditions.
2.2 Package Awọn akoonu

Figure 2.3: The ANENG SZ308 Multimeter package includes the device, battery, test leads, and manual.
The ANENG SZ308 Digital Multimeter package typically includes:
- ANENG SZ308 Digital Multimeter x 1
- Batiri 9V x 1
- Standard Test Leads x 1 pair
- Insulated Multimeter Test Probes (Piercing Probes) x 2
- Ilana olumulo x 1
3. Eto
3.1 Fifi sori batiri

Figure 3.1: Proper installation of the 9V battery in the multimeter's rear compartment.
- Rii daju pe multimeter ti wa ni pipa.
- Wa ideri apo batiri naa ni ẹhin multimeter naa.
- Lo ẹ̀rọ ìdènà láti yọ ìdènà tí ó so ìbòrí batiri náà mọ́ kúrò.
- Fara yọ ideri kuro.
- So batiri 9V pọ mọ awọn agekuru batiri, ki o wo polarity ti o tọ (+ si + ati - si -).
- Fi batiri sinu yara naa ki o si fi ideri naa pada, ki o si fi skru naa so o mọ.
3.2 Nsopọ Awọn itọsọna Igbeyewo
So awọn itọsọna idanwo pọ si awọn jacks titẹ sii ti o yẹ lori multimeter:
- Fi sii dudu igbeyewo asiwaju sinu COM (Wọpọ) jack.
- Fi sii pupa igbeyewo asiwaju sinu VΩmA jack fun voltage, resistance, and small current measurements.
- For measuring currents greater than 200mA (up to 10A), insert the pupa igbeyewo asiwaju sinu 10A jaki.
CAUTION: Always ensure test leads are correctly inserted for the desired measurement to prevent damage to the multimeter or personal injury.
4. Awọn ilana Iṣiṣẹ
The ANENG SZ308 features a user-friendly rotary dial for selecting various measurement functions.

Figure 4.1: The function dial allows selection of different measurement modes.
4.1 AC / DC Voltage Idiwon

Àwòrán 4.2: Wíwọ̀n ìpele ACtage at an electrical outlet using the multimeter.
- Turn the function dial to the desired AC Voltage (V~) or DC Voltage (V=) range.
- So okun idanwo dudu naa mọ jaketi COM ati okun idanwo pupa naa mọ jaketi VΩmA.
- Fi ọwọ kan awọn ohun elo idanwo si awọn aaye nibiti o fẹ lati wọn iwọn diduntage.
- Ka voltage iye lori LCD iboju.
4.2 Ìwọ̀n Ìsinsìnyí DC
The ANENG SZ308 can measure DC current in various ranges.
- Turn the function dial to the desired DC Current (A=) range (e.g., 200m, 10A).
- For currents up to 200mA, connect the black test lead to COM and the red test lead to VΩmA.
- For currents up to 10A, connect the black test lead to COM and the red test lead to the 10A jack.
- Open the circuit where you want to measure current and connect the multimeter in series.
- Read the current value on the LCD screen.
4.3 Resistance Wiwọn
- Turn the function dial to the Resistance (Ω) range.
- Connect the black test lead to COM and the red test lead to VΩmA.
- Rii daju pe iyika naa ti ni agbara ṣaaju idiwọn resistance.
- Touch the test probes across the component or circuit you wish to measure.
- Read the resistance value on the LCD screen.
4.4 Igbeyewo Ilọsiwaju
- Turn the function dial to the Continuity (buzzer icon) range.
- Connect the black test lead to COM and the red test lead to VΩmA.
- Rí i dájú pé ẹ̀rọ náà kò ní agbára púpọ̀.
- Fi ọwọ́ kan àwọn ohun ìdánwò náà sí àwọn ojú méjì tí o fẹ́ ṣàyẹ̀wò fún ìtẹ̀síwájú.
- If there is continuity (low resistance), the multimeter will emit an audible beep.
4.5 Idanwo Diode
- Turn the function dial to the Diode (diode symbol) range.
- Connect the black test lead to COM and the red test lead to VΩmA.
- Rii daju pe diode ti ge-asopo lati Circuit.
- Fi ohun èlò pupa náà sí orí anode náà, kí ohun èlò dúdú náà sì wà lórí katódì ti diode náà.
- Ka siwaju voltage drop on the LCD screen. Reverse the probes; an open circuit (OL) reading indicates a good diode.
4.6 hFE Measurement (Transistor Test)

Figure 4.3: Using the hFE function to test transistors.
- Turn the function dial to the hFE range.
- Identify the type of transistor (NPN or PNP) and its emitter, base, and collector leads.
- Insert the transistor leads into the corresponding holes in the hFE socket.
- Read the hFE value (DC current gain) on the LCD screen.
4.7 Ìjáde Ìgbì Onígun Mẹ́rin

Figure 4.4: The multimeter can generate a square wave signal for testing.
- Turn the function dial to the Square Wave (square wave symbol) setting.
- Connect the test leads to the VΩmA and COM jacks.
- The multimeter will output a square wave signal through the test leads, which can be used for testing audio circuits or other electronic components.
4.8 Data idaduro Išė
Tẹ awọn DIMU button to freeze the current reading on the LCD screen. Press it again to release the hold and resume live measurements.
4.9 Imọlẹ ẹhin
Tẹ awọn Imọlẹ ẹhin button (often indicated by a light bulb symbol) to illuminate the LCD screen for better visibility in low-light conditions. Press it again to turn off the backlight.
5. Itọju
5.1 Batiri Rirọpo
When the low battery indicator appears on the LCD, replace the 9V battery as described in Section 3.1. Using a low battery can lead to inaccurate readings.
5.2 Ninu
Nu c ti multimeter naaasing pẹlu ipolowoamp Aṣọ àti ọṣẹ ìfọṣọ díẹ̀. Má ṣe lo àwọn ohun ìfọṣọ tàbí àwọn ohun tí ó ń yọ́ nǹkan. Rí i dájú pé ẹ̀rọ náà gbẹ pátápátá kí o tó lò ó.
5.3 Fiusi Rirọpo
The ANENG SZ308 is equipped with internal fuses for overload protection. If the multimeter fails to measure current, the fuse may need replacement. Refer to the internal diagram or contact customer support for guidance on fuse specifications and replacement procedures. Always replace with a fuse of the same type and rating.
6. Laasigbotitusita
- Ko si ifihan tabi ifihan ti ko lagbara: Check battery installation. Replace the 9V battery if low battery indicator is on or if the display is dim.
- No reading in current mode: Check if the test leads are connected to the correct current jacks (VΩmA or 10A) and if the fuse is intact.
- "OL" (Overload) displayed: The measured value exceeds the selected range. Select a higher range or ensure the circuit is within the multimeter's capabilities.
- Awọn kika ti ko pe: Ensure the battery is not low, test leads are properly connected, and the correct function is selected. Avoid strong electromagnetic interference.
7. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Brand | ANENG |
| Awoṣe | SZ308 |
| Ifihan Ka | 2000 Awọn iṣiro |
| Orisun agbara | Batiri 9V (pẹlu) |
| AC Voltage | Titi di 750V |
| DC Voltage | Titi di 1000V |
| DC Lọwọlọwọ | Titi di 10A |
| Atako | Títí dé 20MΩ |
| Itesiwaju | Bẹ́ẹ̀ni (pẹ̀lú buzzer) |
| Idanwo Diode | Bẹẹni |
| Idanwo hFE | Bẹẹni |
| Ijade Igun Square | Bẹẹni |
| Idaduro data | Bẹẹni |
| Imọlẹ ẹhin | Bẹẹni |
| Apọju Idaabobo | Yes (by fuses) |
| Ọja Mefa | 50 x 50 x 20 mm |
| Iwọn Nkan | 0.6 giramu |
| Àwọ̀ | Dudu |
8. Atilẹyin ọja ati Support
ANENG electrical testers come with service and technical support. For warranty claims, technical assistance, or any questions regarding your ANENG SZ308 Digital Multimeter, please refer to the contact information provided with your purchase or visit the official ANENG webojula. Jọwọ ṣe idaduro ẹri rira rẹ fun awọn idi atilẹyin ọja.