TOOLTOP TT-ET14S+Macro lens

TOOLTOP ET14S 2-in-1 Thermal Imager & Multimeter User Manual

Model: TT-ET14S+Macro lens

Ọrọ Iṣaaju

This user manual provides comprehensive instructions for the safe and effective operation of your TOOLTOP ET14S 2-in-1 Thermal Imager and Multimeter. This device integrates a high-resolution thermal camera with a full-featured digital multimeter, offering a versatile tool for various diagnostic and inspection tasks. Please read this manual thoroughly before use and retain it for future reference.

Alaye Aabo

Nigbagbogbo faramọ awọn iṣọra ailewu atẹle lati yago fun ipalara tabi ibajẹ si ẹrọ naa:

  • Ma ṣe gbiyanju lati tunto tabi yi ẹrọ naa pada.
  • Ensure the device is turned off before connecting or disconnecting test leads.
  • Má ṣe kọjá ìwọ̀n ìtẹ̀síwájú tó pọ̀ jùlọ fún ìpele ìpeletage, lọwọlọwọ, tabi iwọn otutu.
  • Use appropriate personal protective equipment (PPE) when working with electrical circuits or high temperatures.
  • Keep the device away from water, dust, and extreme temperatures.
  • Refer to the warning label on the back of the device for additional safety instructions.

Ohun ti o wa ninu Apoti

Daju pe gbogbo awọn nkan ti a ṣe akojọ rẹ si isalẹ wa ninu package rẹ:

  • ET14S Thermal Imager & Multimeter
  • Makiro lẹnsi
  • Instrument Storage Bag
  • Multimeter Probes (Test Leads)
  • Data Line (USB Cable)
  • Ọja Afowoyi
  • Apoti apoti
Contents of the ET14S package including the device, macro lens, storage bag, probes, cable, and manual.

Image: Components included in the ET14S package, showing the main unit, macro lens, storage bag, multimeter probes, data cable, and product manual.

Ọja Pariview

The TOOLTOP ET14S combines a high-resolution thermal imager with a precise digital multimeter. It features a 2.8-inch IPS high-definition screen for clear display of both thermal images and electrical measurements.

Iwaju view of the ET14S device showing the screen and controls.

Aworan: Iwaju view of the ET14S device, illustrating its dual functionality as a thermal imager and multimeter with its display screen and control buttons.

Close-up of the ET14S screen displaying thermal image and multimeter readings.

Aworan: A alaye view of the ET14S screen, showing both a thermal image overlay and digital multimeter readings simultaneously.

Awọn ẹya pataki:

  • ISR240x240 Thermal Camera: Upgraded imaging pixels of 240x240 and 25Hz image capture frequency for detailed thermal analysis.
  • High-precision Multimeter: 9999 counts True RMS multimeter for accurate electrical measurements.
  • Igbesi aye batiri gigun: Up to 8 hours of continuous use with a universal 18650 rechargeable battery.
  • Iwapọ ati Gbigbe: Ergonomic design with a 2.8-inch screen and innovative stand.
  • Ibi iwọn otutu ti o tobi: -20℃ to +550℃ with ±2℃ or ±2% accuracy.
  • Lẹ́ǹsì Mákrókì Àṣàyàn: For detailed inspection of small components like PCBs.

Ṣeto

1. Fifi sori batiri ati gbigba agbara:

The ET14S uses a rechargeable 18650 lithium battery. Ensure the battery is properly installed and charged before first use.

  1. Wa yara batiri ni ẹhin ẹrọ naa.
  2. Ṣii ideri iyẹwu naa.
  3. Insert the 18650 battery, observing the correct polarity (+/-).
  4. Pa ideri batiri naa ni aabo.
  5. Connect the device to a power source using the provided USB data line for charging. The charging indicator will show the charging status.
ET14S device with battery compartment open, showing the 18650 battery and USB charging.

Image: The ET14S with its battery compartment open, illustrating the removable 18650 lithium battery and the USB charging port.

2. Attaching the Macro Lens (Optional):

For detailed inspection of small objects or PCB boards, attach the included macro lens.

  1. Locate the macro lens attachment point on the top of the device, near the thermal camera lens.
  2. Align the macro lens with the attachment mechanism.
  3. Slide or clip the macro lens into place until it is securely fastened over the thermal camera lens.
  4. To remove, gently slide or unclip the macro lens.
ET14S device showing the optional macro lens attachment and its effect on thermal imaging.

Image: The ET14S device highlighting the optional macro lens and demonstrating its capability for detailed thermal inspection of small components like PCBs.

Awọn ilana Iṣiṣẹ

1. Titan tabi Pipa:

Press and hold the power button (usually located on the side or front panel) to turn the device on or off.

2. Lilọ kiri ni wiwo:

The ET14S features a user-friendly interface with dedicated buttons for different functions. Use the navigation buttons (up, down, left, right, OK/Enter) to move through menus and select options.

3. Ipo Aworan Gbona:

In thermal imaging mode, the screen displays a real-time infrared image. The device automatically detects and displays temperature readings for the hottest and coldest points, as well as a central spot temperature.

ET14S screen displaying a thermal image with temperature readings.

Image: The ET14S screen showing a thermal image with temperature distribution and specific temperature readings for analysis.

  • Àṣàyàn Pálẹ́ẹ̀tì: Use the menu to select different color palettes (e.g., Iron, Rainbow, Gray) to visualize temperature differences.
  • Atunse Emissivity: Adjust emissivity settings based on the material being inspected for accurate temperature measurements.
  • Aworan: Press the designated button to capture and save thermal images.

4. Multimeter Mode:

The ET14S functions as a full-featured True RMS multimeter. Connect the test leads to the appropriate input jacks (COM, VΩHz, A) and select the desired measurement function using the rotary dial or function buttons.

ET14S screen displaying multimeter readings for voltage ati lọwọlọwọ.

Image: The ET14S screen displaying various multimeter readings, including voltage, resistance, and frequency, demonstrating its electrical measurement capabilities.

  • VoltagÌwọ̀n e (AC/DC): Select V~ for AC voltage or V- for DC voltage.
  • Ìwọ̀n Lọ́wọ́lọ́wọ́ (AC/DC): Select A~ for AC current or A- for DC current. Ensure correct lead connection for current measurements.
  • Resistance (Ω), Continuity, Diode: Select the Ω symbol for resistance, continuity buzzer, or diode test.
  • Capacitance (F), Frequency (Hz), Duty Cycle (%): Select the appropriate symbols for these measurements.
  • Non-Olubasọrọ Voltage (NCV): Lo iṣẹ NCV lati ṣe awari AC voltage lai taara olubasọrọ.
  • Idaduro data: Tẹ bọtini HOLD lati di kika lọwọlọwọ lori ifihan.
  • Aṣayan Ibiti: The device typically features auto-ranging, but manual range selection may be available.

Awọn ohun elo

The TOOLTOP ET14S is a versatile tool suitable for a wide range of applications, including but not limited to:

  • Power System Maintenance: Identifying overheating components in electrical panels, circuit breakers, and wiring.
  • Underfloor Heating Inspection: Locating heating elements and identifying blockages or leaks in radiant heating systems.
  • Automobile Maintenance: Diagnosing engine overheating, checking brake temperatures, and inspecting electrical systems.
  • PCB Board Repair and Electronic Inspection: Pinpointing hot spots on circuit boards, identifying faulty components, and verifying thermal performance.
  • Pipeline Heating Inspection: Detecting insulation failures or blockages in industrial pipelines.
  • Àyẹ̀wò Ilé: Identifying insulation gaps, moisture intrusion, and HVAC issues.
Collage of images showing various applications of the ET14S, including power system, underfloor heating, automobile, and PCB inspection.

Image: A visual representation of the wide range of applications for the ET14S, including power system maintenance, underfloor heating, automobile diagnostics, and PCB board repair.

Itoju

1. Ninu:

Nu ẹrọ naa pẹlu asọ, damp cloth. Do not use abrasive cleaners or solvents. Ensure the lenses are clean and free of dust or smudges for optimal thermal imaging performance.

2. Itọju Batiri:

To prolong battery life, charge the device regularly and avoid completely draining the battery. If storing for extended periods, charge the battery to approximately 50% and store in a cool, dry place.

3. Ibi ipamọ:

Store the ET14S in its provided storage bag or a protective case when not in use to prevent damage from impacts or dust. Avoid storing in areas with extreme temperatures or high humidity.

Laasigbotitusita

IsoroOwun to le FaOjutu
Ẹrọ naa ko ṣiṣẹ.Batiri kekere tabi ti o ti dinku. Fifi sori ẹrọ batiri ti ko tọ.Gba agbara batiri naa. Rii daju pe batiri naa wa pẹlu polarity ti o tọ.
Awọn kika iwọn otutu ti ko pe.Incorrect emissivity setting. Lens is dirty. Object is too far or too close.Adjust emissivity for the target material. Clean the thermal lens. Ensure proper measurement distance.
Multimeter readings are unstable or incorrect.Loose test lead connections. Incorrect function selected. Battery low.Check and secure test lead connections. Verify the correct measurement function is selected. Charge the battery.
Iboju ti ṣofo tabi aotoju.Aṣiṣe sọfitiwia.Perform a hard reset by holding the power button for 10-15 seconds, or remove and reinsert the battery.

Awọn pato

Ẹya ara ẹrọSipesifikesonu
Ipinnu Gbona240x240 awọn piksẹli
Iwọn fireemu25Hz
Iwọn otutu-20℃ si +550℃ (-4℉ si +1022℉)
Yiye iwọn otutu±2℃ or ±2% (whichever is greater)
Ipinnu Iwọnwọn0.1 ℃ / 0.1 ℉
Awọn iṣiro Multimeter9999 counts (True RMS)
Iboju ifihan2.8-inch IPS High-Definition LCD
Batiri IruRechargeable 18650 Lithium Battery
Igbesi aye batiriTiti di wakati 8 (lilo tẹsiwaju)
Iwọn Nkan1 Kilogram (2.2 Pounds)
Awọn iwọn7.87 x 5.91 x 3.94 inches (Awọn iwọn idii)
Awọn iwe-ẹriCE, RoHS

Atilẹyin ọja ati Support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact TOOLTOP customer service directly. The EU spare part availability duration is 1 year.

Olupese: AKIYESI

Nọmba Awoṣe Nkan: TT-ET14S+Macro lens

For further assistance, please visit the official TOOLTOP webaaye tabi kan si awọn ile-iṣẹ iṣẹ ti a fun ni aṣẹ.

© 2025 TOOLTOP. All rights reserved.