Aramox TM919BK

Aramox TM919BK Digital Programmable Timer User Manual

Model: TM919BK

1. Ifihan

The Aramox TM919BK is a versatile digital programmable timer designed for controlling electrical appliances, such as household and garden lighting, with precision. It features 24-hour/7-day programming capabilities, allowing for up to 16 ON/OFF settings per day and 15 weekly combinations. Equipped with an LCD screen and an internal battery for program backup, this timer ensures reliable operation even during power interruptions.

Aramox TM919BK Digital Programmable Timer with clear cover open, showing the LCD display and control buttons.

Image: The Aramox TM919BK Digital Programmable Timer with its protective clear cover open, revealing the LCD screen displaying time and day, along with the red control buttons for programming.

2. Alaye Aabo

  • Ge asopọ agbara nigbagbogbo ṣaaju fifi sori ẹrọ tabi itọju lati ṣe idiwọ mọnamọna.
  • Onímọ̀ nípa iná mànàmáná tàbí ẹni tó ní ìmọ̀ gbọ́dọ̀ fi sori ẹ̀rọ náà.
  • Rii daju pe iwọn didun aago naatage and current ratings (85-265V AC, 30A) are compatible with your application.
  • Do not expose the device to excessive moisture or extreme temperatures outside its specified operating range (-10℃ to 50℃).
  • Jeki kuro ni arọwọto awọn ọmọde.

3. Package Awọn akoonu

Jọwọ ṣayẹwo package fun awọn nkan wọnyi:

  • 1 x Aramox TM919BK Digital Programmable Timer
  • 1 x Itọsọna olumulo

4. Awọn ẹya Ọja

  • Eto: 24 hours/7 days a week programming with 16 ON/OFF settings per day and 15 weekly combinations.
  • Iṣakoso Afowoyi: Ability to manually override programmed settings.
  • Ifihan LCD: Clear LCD screen with LED indicators for easy readability.
  • DIN Rail Oke: Designed for easy installation on a 35mm DIN rail.
  • Afẹyinti Agbara: Built-in high-capacity battery retains programmed settings during power failures.
  • Jakejado Voltage Ibiti: Operates on 85-265V AC.
  • Agbara giga: Supports loads up to 30A (5000W).
  • Iṣẹ Ika: Maximum 24-hour countdown.

5. Eto ati fifi sori

5.1. Iṣagbesori

The TM919BK timer is designed for 35mm DIN rail mounting. Securely attach the timer to the DIN rail in your electrical panel or enclosure.

Aramox TM919BK Digital Programmable Timer with clear cover closed, showing the DIN rail mounting clips.

Image: The Aramox TM919BK Digital Programmable Timer with its clear cover closed, providing a view of its compact form factor and the integrated clips for DIN rail mounting.

5.2. Awọn gbigbe

Refer to the wiring diagram printed on the timer unit. Ensure all connections are secure and comply with local electrical codes.

  • Àwọn ibùdó 1 àti 2: Power input (85-265V AC).
  • Àwọn ibùdó 3, 4, àti 5: Output contacts for the controlled device. Terminal 4 is common, Terminal 3 is normally closed (NC), and Terminal 5 is normally open (NO). Connect your load between Terminal 4 and Terminal 5 for standard ON/OFF control.

After wiring, restore power to the circuit. The timer's LCD display should illuminate.

6. Awọn ilana Iṣiṣẹ

Close-up of the Aramox TM919BK timer's control buttons and LCD screen.

Aworan: A alaye view of the Aramox TM919BK Digital Programmable Timer's front panel, highlighting the LCD display, the 'ON' indicator, and the programming buttons: P, D+, H+, M+, RESET, and MANUAL.

6.1. Eto/Atunto Ibẹrẹ

Upon first power-up or after a long period without power, the display may be blank or show incorrect time. Press the Tunto button (usually a small recessed button requiring a pointed object) to clear all settings and reset the timer to its default state. The display will show 00:00:00.

6.2. Setting the Current Time and Day

  1. Tẹ awọn P button once. The display will show the current day of the week (e.g., 'Mo' for Monday).
  2. Tẹ D+ to select the correct day of the week.
  3. Tẹ H+ lati ṣeto awọn ti isiyi wakati.
  4. Tẹ M+ lati ṣeto awọn ti isiyi iseju.
  5. Tẹ awọn P button again to exit time setting mode.

6.3. Ṣíṣeto/Ṣíṣeto Awọn Eto TÍTÁN/Ṣípa

Aago naa n ṣe atilẹyin fun awọn eto ON/OFF to 16. Eto kọọkan ni akoko ON ati akoko PA.

  1. Tẹ awọn P button repeatedly until '1 ON' appears on the display. This is your first ON program.
  2. Tẹ D+ to select the desired day(s) for this program. You can choose individual days, weekdays, weekends, or various combinations (e.g., Mo-Fr, Sa-Su, Mo-Su).
  3. Tẹ H+ láti ṣètò wákàtí ON.
  4. Tẹ M+ láti ṣètò ìṣẹ́jú ON.
  5. Tẹ awọn P button again. '1 OFF' will appear. This is the OFF time for your first program.
  6. Repeat steps 2-4 to set the OFF day(s), hour, and minute for '1 OFF'.
  7. Tesiwaju titẹ P láti yípo nípasẹ̀ '2 ON', '2 PA', títí dé '16 ON', '16 PA', kí o sì ṣètò gbogbo ètò bí ó ṣe yẹ.
  8. Lẹhin ti ṣeto gbogbo awọn eto ti o fẹ, tẹ bọtini naa P button until the current time is displayed to save and exit programming mode.

6.4. Yiyọ Afowoyi

Awọn Afọwọṣe button allows you to override the current program state.

  • Tẹ Afọwọṣe once to switch the output from AUTO to ON. The 'ON' indicator will light up.
  • Tẹ Afọwọṣe again to switch the output from ON to OFF. The 'OFF' indicator will light up.
  • Tẹ Afọwọṣe a third time to return to AUTO mode. The timer will follow its programmed schedule.

7. Itọju

  • Ninu: Wipe the timer with a dry, soft cloth. Do not use abrasive cleaners or solvents.
  • Batiri: The internal battery is designed for long-term backup. If the timer frequently loses its settings during power outages, batiri naa le nilo rirọpo nipasẹ onimọ-ẹrọ ti o peye.
  • Ayewo: Lojoojumọ, ṣayẹwo awọn asopọ waya fun wiwọ ati awọn ami ti o wọ.

8. Laasigbotitusita

IsoroOwun to le FaOjutu
Ifihan aago naa ṣofo.Ko si ipese agbara.Check power connections to terminals 1 and 2. Ensure circuit breaker is ON.
Aago naa ko tan/pa ni awọn akoko ti a ṣeto.Incorrect program settings. Timer is in Manual ON/OFF mode.Review program settings (time, day, ON/OFF). Press Afọwọṣe button until 'AUTO' is displayed.
Ẹrù kò tan/pa.Incorrect wiring. Faulty load.Verify wiring to terminals 3, 4, 5. Test the load directly to ensure it is functional.
Aago naa padanu awọn eto lẹhin agbara outage.Internal battery depleted or faulty.The internal battery may need replacement. Contact customer support.

9. Awọn pato

Ẹya ara ẹrọSipesifikesonu
AwoṣeTM919BK
Ibi ti ina elekitiriki ti nwa85 ~ 265V AC
Igbohunsafẹfẹ50/60Hz
Agbara30A (resistive load up to 5000W)
Akoko Ibiti1 minute ~ 168 hours
Awọn eto16 ON/OFF per day, 15 combinations per week
Agbara agbara<5VA
Àṣìṣe Àpapọ̀< 1 second/day
Iwọn otutu-10 ~ 50 ℃
Ọriniinitutu<95% RH
Iṣagbesori35mm DIN Rail
Iwọn (D x W x H)3.54" x 2.76" x 1.97" (90mm x 70mm x 50mm)
Iwọn Nkan147 giramu

10. Atilẹyin ọja ati Support

For warranty information or technical support, please contact Aramox customer service through your purchase platform or the official Aramox website. Please have your model number (TM919BK) and purchase details ready when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.