1. Ifihan
This manual provides comprehensive instructions for the setup, operation, maintenance, and troubleshooting of your Generic PH-W3988 Water Quality Monitor. This device is a multiparameter 6-in-1 analyzer designed for accurate measurement of pH, Electrical Conductivity (EC), Total Dissolved Solids (TDS), Salinity (SALT), Specific Gravity (S.G), and Temperature in various water samples. It features Wi-Fi connectivity for remote monitoring via a dedicated application.
2. Package Awọn akoonu
Jọwọ rii daju pe gbogbo awọn ohun ti a ṣe akojọ si isalẹ wa ninu apo rẹ:
- PH-W3988 Water Quality Monitor Unit
- Power Adapter (specific to region, e.g., AU Plug)
- pH elekitirodu
- EC/TDS/SALT/S.G/Temp Electrode
- Afowoyi Olumulo (iwe-ipamọ yii)
- Calibration Solutions (pH 4.00, pH 6.86, pH 9.18, EC 1413 µS/cm, EC 12.88 mS/cm - may vary by package)
3. Imọ ni pato
| Paramita | Ibiti o |
|---|---|
| pH | 0.00 - 14.00 pH |
| EC | 0 – 9000 µS/cm, 0 – 199.0 mS/cm |
| TDS | 0 – 19990 ppm, 0 – 199.0 ppt |
| Iyọ | 0 – 199.9 ppt, 0% – 20% |
| S.G (Specific Gravity) | 0.990 – 1.400 |
| Iwọn otutu | 0°C – 50°C (32°F – 122°F) |
- Asopọmọra: Wi-Fi (2.4 GHz)
- Awọn iwọn: Isunmọ 131mm x 78mm
- Ìwọ̀n Nkan: Isunmọ 1.76 iwon (50 giramu)
- Ibi ti ina elekitiriki ti nwa: AC/DC Adapter (Input: 100-240V, Output: 5V DC)

4. Awọn ilana iṣeto
- Yọ Ẹrọ naa kuro: Ni ifarabalẹ yọ gbogbo awọn paati kuro ninu apoti.
- Connect Electrodes:
- Connect the pH electrode to the designated port (usually marked "pH").
- Connect the EC/TDS/SALT/S.G/Temp electrode to its designated port (usually marked "EC/TDS/SALT").
- Ensure connections are secure to prevent inaccurate readings.
- Asopọ agbara: Insert the power adapter into the monitor's power input port, then plug the adapter into a suitable electrical outlet. The device will power on automatically.
- Fi omi ṣan ni ibẹrẹ: Before first use, rinse the electrodes with distilled or deionized water to remove any storage solution or contaminants. Gently blot dry with a lint-free cloth.
- Ṣe igbasilẹ Ohun elo: Wa fun the "Smart Life" or "Tuya Smart" app (refer to packaging or quick start guide for specific app name) on your smartphone's app store (iOS or Android) and install it.
5. Ṣiṣẹ Atẹle
5.1 Ipilẹ isẹ
- Agbara Tan: The device powers on automatically when connected to power.
- Aṣayan Ipo: Tẹ awọn MODE button to cycle through the different measurement parameters displayed on the screen (e.g., TDS/EC/SALT/S.G/TEMP and pH/TEMP).
- Ẹka ìwọ̀ntúnwọ̀nsì: Tẹ awọn TEMP CAL/+ button briefly to switch between Celsius (°C) and Fahrenheit (°F) temperature units.
- Iwọn: Immerse the electrodes into the water sample you wish to test. Ensure the electrode tips are fully submerged and free of air bubbles. Allow a few moments for the readings to stabilize on the display.
5.2 APP Remote Functionality
- Asopọ Wi-Fi:
- Ensure your monitor is powered on and within range of a 2.4 GHz Wi-Fi network.
- Open the installed "Smart Life" or "Tuya Smart" app (refer to packaging or quick start guide for specific app name) on your smartphone.
- Follow the in-app instructions to add a new device. You may need to put the monitor into pairing mode (often by pressing and holding the Wi-Fi button or a combination of buttons until the Wi-Fi indicator blinks rapidly).
- Once connected, the Wi-Fi icon on the monitor's display will become solid.
- Abojuto latọna jijin: Nipasẹ ohun elo, o le view real-time readings, set alarms for specific parameter thresholds, and access historical data.
6. Iṣatunṣe
Regular calibration is essential for maintaining the accuracy of your water quality monitor. Always use fresh, standard calibration solutions.
6.1 pH odiwọn
- Igbaradi: Rinse the pH electrode with distilled water and gently blot dry. Prepare pH 6.86, pH 4.00, and pH 9.18 standard buffer solutions.
- First Point (pH 6.86): Immerse the pH electrode into the pH 6.86 buffer solution. Press and hold the CAL button until the display shows "CAL" or starts blinking. The device will automatically recognize the buffer and calibrate. Wait for the reading to stabilize and the calibration to complete (usually indicated by a stable reading or a confirmation message).
- Second Point (pH 4.00): Rinse the electrode again. Immerse it into the pH 4.00 buffer solution. Press and hold the CAL button. The device will calibrate to the second point.
- Third Point (pH 9.18 - Optional): For higher accuracy, especially in alkaline ranges, repeat the process with pH 9.18 buffer solution.
- Ipari: After calibration, rinse the electrode and store it properly.
6.2 EC/TDS/SALT/S.G Calibration
- Igbaradi: Rinse the EC electrode with distilled water and gently blot dry. Prepare a standard EC calibration solution (e.g., 1413 µS/cm or 12.88 mS/cm).
- Iṣatunṣe: Immerse the EC electrode into the standard solution. Press and hold the CAL bọtini (tabi awọn TEMP CAL/+ button if it doubles as EC calibration, refer to specific device markings). The device will automatically calibrate. Wait for the reading to stabilize.
- Ipari: After calibration, rinse the electrode and store it properly.
Note: TDS, SALT, and S.G values are typically derived from the EC measurement and temperature compensation. Calibrating EC usually calibrates these parameters simultaneously.
7. Itọju
- Ninu Electrode: Regularly rinse electrodes with distilled water after each use. If electrodes become dirty or readings are erratic, clean them gently with a soft brush and a mild cleaning solution (e.g., diluted detergent or specific electrode cleaning solution), then rinse thoroughly.
- Itọju itanna: Always store pH electrodes in a suitable storage solution (e.g., 3M KCl solution or pH 4 buffer). Do not store pH electrodes dry. EC electrodes can typically be stored dry after rinsing.
- Ohun elo Ninu: Mu ese akọkọ nu pẹlu asọ, damp asọ. Ma ṣe lo awọn afọmọ abrasive tabi fi ibọmi apakan akọkọ sinu omi.
- Rirọpo Elekitirodu: Electrodes have a limited lifespan and may need replacement if they no longer calibrate correctly or provide stable readings.
8. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ko si agbara/Ifihan ti a ti pa | Adapter agbara ti ge asopọ tabi o ni abawọn. | Check power connections. Ensure adapter is working. |
| Àwọn ìwé kíkà tí kò péye tàbí tí kò dúró ṣinṣin |
|
|
| Ikuna asopọ Wi-Fi |
|
|
| "Err" or "---" displayed | Measurement out of range or electrode fault. | Ṣayẹwo boya sample is within the device's measurement range. Clean or replace electrodes if necessary. |
9. atilẹyin ọja Information
This Generic PH-W3988 Water Quality Monitor is covered by a standard manufacturer's warranty against defects in materials and workmanship for a period of odun kan from the date of purchase. This warranty does not cover damage caused by misuse, accident, unauthorized modification, neglect, or normal wear and tear of consumable parts like electrodes. Please retain your proof of purchase for warranty claims.
10. Onibara Support
For technical assistance, troubleshooting, or warranty inquiries, please contact your retailer or the manufacturer's customer support. Refer to the product packaging or the retailer's webojula fun pato olubasọrọ awọn alaye.
Please have your model number (PH-W3988) and purchase date available when contacting support.