RDH77XSR D150

Generic 6" DI D.D. Wafer Check Valve Instruction Manual

Model: RDH77XSR D150

1. Ifihan

This manual provides essential information for the proper installation, operation, and maintenance of the Generic 6" Ductile Iron Double Disc Wafer Check Valve, Model RDH77XSR D150. Please read these instructions thoroughly before installation or use to ensure safe and efficient performance.

1.1 Ọja Loriview

The 6" Ductile Iron Double Disc Wafer Check Valve is designed for reliable backflow prevention in various industrial and plumbing applications. It features a compact wafer design for easy installation between flanges and a dual-disc spring-loaded mechanism for quick closing, minimizing water hammer.

1.2 Key Awọn ẹya ara ẹrọ

  • Ikole ti o tọ: Manufactured from Ductile Iron ASTM A536, 65-45-12 for enhanced strength, pressure resistance, and longevity.
  • Corrosion-Resistant Disc: Equipped with a 316 Stainless Steel disc, ensuring excellent resistance to rust and chemical corrosion.
  • Leak-Proof Sealing: Features an EPDM seat for tight sealing performance and outstanding resistance to water and mild chemicals.
  • Compact Wafer Design: Facilitates easy installation between flanges, reducing space requirements and simplifying maintenance.
  • Reliable Backflow Prevention: A dual-disc spring-loaded mechanism ensures quick closing to prevent reverse flow and water hammer.
Generic 6 inch Ductile Iron Double Disc Wafer Check Valve

Figure 1: Generic 6 inch Ductile Iron Double Disc Wafer Check Valve. This image shows the overall design of the valve, highlighting its compact wafer style and robust construction.

2. Alaye Aabo

Always observe general safety precautions when handling and installing industrial equipment. Failure to follow these instructions may result in property damage, injury, or death.

  • Rí i dájú pé ẹ̀rọ náà ti bàjẹ́, ó sì ti gbóná kí ó tó fi sori ẹ̀rọ tàbí kí ó ṣe àtúnṣe.
  • Wọ ohun elo aabo ara ẹni ti o yẹ (PPE), pẹlu awọn gilaasi aabo, awọn ibọwọ, ati awọn aṣọ aabo.
  • Handle the valve with care to prevent damage to sealing surfaces or internal components.
  • Do not exceed the specified working pressure or temperature range.
  • Consult local codes and regulations for proper installation procedures.

3. Irinše ati Ohun elo

The Generic 6" DI D.D. Wafer Check Valve is constructed from high-quality materials designed for durability and performance:

  • Ohun elo ara: Ductile Iron ASTM A536, 65-45-12
  • Ohun elo Disiki: 316 Irin alagbara
  • Ohun elo ijoko: EPDM (Ethylene Propylene Diene Monomer)
  • Aso: Fusion Bonded Epoxy Coating in accordance with ANSI/AWWA C550

4. Eto ati fifi sori

Proper installation is crucial for the optimal performance and longevity of the check valve. This valve is designed for installation between flanges.

  1. Igbaradi:
    • Ensure the pipeline is clean and free of debris.
    • Verify that the valve's specifications (size, pressure, temperature) match the system requirements.
    • Confirm that the mating flanges are clean and properly aligned.
  2. Iṣalaye:
    • Install the valve with the flow arrow on the valve body pointing in the direction of the intended flow.
    • The valve can be installed in horizontal or vertical pipelines. For vertical installations, ensure the flow is upwards.
  3. Ibi:
    • Carefully insert the wafer check valve between the two mating flanges.
    • Ensure the valve is centered and the discs can open and close freely without obstruction from the pipe walls or flange bolts.
  4. Bolting:
    • Insert the flange bolts through the assembly.
    • Tighten the bolts gradually and evenly in a crisscross pattern to ensure uniform compression of the gaskets and proper seating of the valve. Avoid over-tightening.
    • Flange specifications: ASME B16.1 CL125, ASME B16.5 CL150.
  5. Ṣayẹwo fifi sori lẹhin:
    • After installation, slowly pressurize the system and check for leaks.
    • Observe the valve's operation during initial system startup.

5. Isẹ

The Generic 6" DI D.D. Wafer Check Valve is an automatic flow control device. It operates by allowing fluid to flow in one direction and preventing backflow in the opposite direction.

  • Forward Flow: When fluid flows in the designated direction, the pressure of the fluid pushes the dual discs open against the spring tension, allowing flow through the valve.
  • Idena sisan pada: If the flow stops or reverses, the spring tension, combined with the back pressure of the fluid, forces the discs closed against the EPDM seat, preventing reverse flow and protecting upstream equipment.
  • Ipa Ṣiṣẹ: Titi di 300 PSI.
  • Iwọn otutu: 0℃ - 80℃.
  • Tamper Yipada: Normally Open and Closed options are available for monitoring valve position (if equipped).

6. Itọju

The Generic 6" DI D.D. Wafer Check Valve is designed for minimal maintenance. Regular inspection is recommended to ensure continued reliable operation.

  • Ayewo Igbakọọkan: Regularly inspect the valve for external leaks, corrosion, or signs of damage.
  • Ṣíṣàyẹ̀wò Iṣẹ́: Periodically verify that the valve is opening and closing correctly by observing system pressure and flow.
  • Ninu: If the system fluid contains particulates, periodic flushing of the pipeline may be necessary to prevent debris accumulation around the discs and seat.
  • Rọpo: If the valve shows signs of significant wear, damage, or consistent leakage, it should be replaced. Internal components are generally not field-serviceable.

7. Laasigbotitusita

This section addresses common issues that may arise during the operation of the check valve.

IsoroOwun to le FaOjutu
Valve not closing completely (backflow)
  • Debris lodged in the seat.
  • Damaged EPDM seat or disc.
  • Weak or broken spring.
  • Flush the system to remove debris.
  • Inspect and replace the valve if components are damaged.
Valve not opening fully (restricted flow)
  • Insufficient upstream pressure.
  • Debris obstructing disc movement.
  • Incorrect installation (e.g., misaligned).
  • Verify system pressure.
  • Fọ eto naa.
  • Re-check installation and alignment.
Ita jijo
  • Improperly tightened flange bolts.
  • Damaged flange gaskets.
  • Cracked valve body.
  • Re-tighten flange bolts evenly.
  • Replace flange gaskets.
  • Replace the valve if the body is cracked.

For issues not covered here, or if troubleshooting steps do not resolve the problem, contact customer support.

8. Awọn pato

IwaẸ̀kúnrẹ́rẹ́
Nọmba awoṣeRDH77XSR D150
Iwọn6 inches (Available sizes: 2" - 12")
Ohun elo araDuctile Iron ASTM A536, 65-45-12
Disc Material316 Irin alagbara
Ohun elo ijokoEPDM
Ọna apẹẹrẹMSS SP-67
Top Flange StandardISO 5211
Ṣiṣẹ Ipa300 PSI
Iwọn otutu0℃ - 80℃ (32°F - 176°F)
AsoFusion Bonded Epoxy Coating (ANSI/AWWA C550)
Flange SpecificationASME B16.1 CL125, ASME B16.5 CL150
OlupeseNASCO Supply LLC

9. Atilẹyin ọja ati Support

Ọja yi wa pẹlu kan 1 Odun atilẹyin ọja from the date of purchase, covering defects in materials and workmanship under normal use and service.

For warranty claims, technical assistance, or support, please contact NASCO Supply LLC, the manufacturer. Ensure you have your model number (RDH77XSR D150) and purchase details available when contacting support.

Olupese: NASCO Supply LLC

For further assistance, please refer to the contact information provided at the point of purchase or on the manufacturer's official webojula.

Awọn iwe aṣẹ ti o jọmọ - RDH77XSR D150

Ṣaajuview FSP D150-BH8 Series DC-DC Converter Technical Datasheet
Comprehensive technical datasheet for the FSP D150-BH8 Series DC-DC converter, featuring 150W power output, ultra-wide input voltage range, and industrial applications. Includes detailed specifications, selection guide, EMC compliance, and mechanical dimensions.
Ṣaajuview DUURA Ice Maker D150 Series Service, fifi sori ẹrọ, ati ilana itọnisọna
Itọsọna okeerẹ fun awọn oluṣe yinyin jara DUURA D150, iṣẹ ibora, fifi sori ẹrọ, iṣẹ ṣiṣe, mimọ, itọju, ati laasigbotitusita. Pẹlu awọn pato imọ-ẹrọ ati awọn iṣọra ailewu.
Ṣaajuview Nexxt Solutions Smart Wi-Fi Door Lock Deadbolt (NHS-D150) - Features & Specifications
Explore the Nexxt Solutions Smart Wi-Fi Door Lock Deadbolt (NHS-D150). This guide details its multiple unlocking modes, advanced security features, comprehensive specifications, and installation compatibility. Enjoy keyless entry, remote access, and enhanced home security with this smart home device.
Ṣaajuview Vasco Ventilation Spare Parts Price List Belgium & Luxembourg
This document is a comprehensive price list for Vasco ventilation spare parts, covering various models including D275, D300E, D400(EP), D500, D60, D150EP II, D275(EP) II, D150 COMPACT, 225 COMPACT, D275(EP) III, D350-D425, DX4, DX5, DX6, C400 Basic/RF, and ENERGY PLUS. It details part numbers, descriptions, and prices for each component.
Ṣaajuview Ìwé Ìtọ́sọ́nà Ọjà: ONFORU LED Flood Light: D50, D100, D150, D200
This product manual provides detailed information for ONFORU LED Flood Lights, including models D50, D100, D150, and D200. It covers product specifications, components, operation instructions, preparation steps, installation guidelines, and FCC compliance information.
Ṣaajuview John Deere D100-D170 Lawn Tractors Technical Manual
Comprehensive technical manual for John Deere D100, D105, D110, D120, D125, D130, D140, D150, D155, D160, and D170 Lawn Tractors, covering repair, operation, tests, and adjustments.