1. Ifihan
This manual provides essential information for the proper installation, operation, and maintenance of the Generic 6" Ductile Iron Double Disc Wafer Check Valve, Model RDH77XSR D150. Please read these instructions thoroughly before installation or use to ensure safe and efficient performance.
1.1 Ọja Loriview
The 6" Ductile Iron Double Disc Wafer Check Valve is designed for reliable backflow prevention in various industrial and plumbing applications. It features a compact wafer design for easy installation between flanges and a dual-disc spring-loaded mechanism for quick closing, minimizing water hammer.
1.2 Key Awọn ẹya ara ẹrọ
- Ikole ti o tọ: Manufactured from Ductile Iron ASTM A536, 65-45-12 for enhanced strength, pressure resistance, and longevity.
- Corrosion-Resistant Disc: Equipped with a 316 Stainless Steel disc, ensuring excellent resistance to rust and chemical corrosion.
- Leak-Proof Sealing: Features an EPDM seat for tight sealing performance and outstanding resistance to water and mild chemicals.
- Compact Wafer Design: Facilitates easy installation between flanges, reducing space requirements and simplifying maintenance.
- Reliable Backflow Prevention: A dual-disc spring-loaded mechanism ensures quick closing to prevent reverse flow and water hammer.

Figure 1: Generic 6 inch Ductile Iron Double Disc Wafer Check Valve. This image shows the overall design of the valve, highlighting its compact wafer style and robust construction.
2. Alaye Aabo
Always observe general safety precautions when handling and installing industrial equipment. Failure to follow these instructions may result in property damage, injury, or death.
- Rí i dájú pé ẹ̀rọ náà ti bàjẹ́, ó sì ti gbóná kí ó tó fi sori ẹ̀rọ tàbí kí ó ṣe àtúnṣe.
- Wọ ohun elo aabo ara ẹni ti o yẹ (PPE), pẹlu awọn gilaasi aabo, awọn ibọwọ, ati awọn aṣọ aabo.
- Handle the valve with care to prevent damage to sealing surfaces or internal components.
- Do not exceed the specified working pressure or temperature range.
- Consult local codes and regulations for proper installation procedures.
3. Irinše ati Ohun elo
The Generic 6" DI D.D. Wafer Check Valve is constructed from high-quality materials designed for durability and performance:
- Ohun elo ara: Ductile Iron ASTM A536, 65-45-12
- Ohun elo Disiki: 316 Irin alagbara
- Ohun elo ijoko: EPDM (Ethylene Propylene Diene Monomer)
- Aso: Fusion Bonded Epoxy Coating in accordance with ANSI/AWWA C550
4. Eto ati fifi sori
Proper installation is crucial for the optimal performance and longevity of the check valve. This valve is designed for installation between flanges.
- Igbaradi:
- Ensure the pipeline is clean and free of debris.
- Verify that the valve's specifications (size, pressure, temperature) match the system requirements.
- Confirm that the mating flanges are clean and properly aligned.
- Iṣalaye:
- Install the valve with the flow arrow on the valve body pointing in the direction of the intended flow.
- The valve can be installed in horizontal or vertical pipelines. For vertical installations, ensure the flow is upwards.
- Ibi:
- Carefully insert the wafer check valve between the two mating flanges.
- Ensure the valve is centered and the discs can open and close freely without obstruction from the pipe walls or flange bolts.
- Bolting:
- Insert the flange bolts through the assembly.
- Tighten the bolts gradually and evenly in a crisscross pattern to ensure uniform compression of the gaskets and proper seating of the valve. Avoid over-tightening.
- Flange specifications: ASME B16.1 CL125, ASME B16.5 CL150.
- Ṣayẹwo fifi sori lẹhin:
- After installation, slowly pressurize the system and check for leaks.
- Observe the valve's operation during initial system startup.
5. Isẹ
The Generic 6" DI D.D. Wafer Check Valve is an automatic flow control device. It operates by allowing fluid to flow in one direction and preventing backflow in the opposite direction.
- Forward Flow: When fluid flows in the designated direction, the pressure of the fluid pushes the dual discs open against the spring tension, allowing flow through the valve.
- Idena sisan pada: If the flow stops or reverses, the spring tension, combined with the back pressure of the fluid, forces the discs closed against the EPDM seat, preventing reverse flow and protecting upstream equipment.
- Ipa Ṣiṣẹ: Titi di 300 PSI.
- Iwọn otutu: 0℃ - 80℃.
- Tamper Yipada: Normally Open and Closed options are available for monitoring valve position (if equipped).
6. Itọju
The Generic 6" DI D.D. Wafer Check Valve is designed for minimal maintenance. Regular inspection is recommended to ensure continued reliable operation.
- Ayewo Igbakọọkan: Regularly inspect the valve for external leaks, corrosion, or signs of damage.
- Ṣíṣàyẹ̀wò Iṣẹ́: Periodically verify that the valve is opening and closing correctly by observing system pressure and flow.
- Ninu: If the system fluid contains particulates, periodic flushing of the pipeline may be necessary to prevent debris accumulation around the discs and seat.
- Rọpo: If the valve shows signs of significant wear, damage, or consistent leakage, it should be replaced. Internal components are generally not field-serviceable.
7. Laasigbotitusita
This section addresses common issues that may arise during the operation of the check valve.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Valve not closing completely (backflow) |
|
|
| Valve not opening fully (restricted flow) |
|
|
| Ita jijo |
|
|
For issues not covered here, or if troubleshooting steps do not resolve the problem, contact customer support.
8. Awọn pato
| Iwa | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Nọmba awoṣe | RDH77XSR D150 |
| Iwọn | 6 inches (Available sizes: 2" - 12") |
| Ohun elo ara | Ductile Iron ASTM A536, 65-45-12 |
| Disc Material | 316 Irin alagbara |
| Ohun elo ijoko | EPDM |
| Ọna apẹẹrẹ | MSS SP-67 |
| Top Flange Standard | ISO 5211 |
| Ṣiṣẹ Ipa | 300 PSI |
| Iwọn otutu | 0℃ - 80℃ (32°F - 176°F) |
| Aso | Fusion Bonded Epoxy Coating (ANSI/AWWA C550) |
| Flange Specification | ASME B16.1 CL125, ASME B16.5 CL150 |
| Olupese | NASCO Supply LLC |
9. Atilẹyin ọja ati Support
Ọja yi wa pẹlu kan 1 Odun atilẹyin ọja from the date of purchase, covering defects in materials and workmanship under normal use and service.
For warranty claims, technical assistance, or support, please contact NASCO Supply LLC, the manufacturer. Ensure you have your model number (RDH77XSR D150) and purchase details available when contacting support.
Olupese: NASCO Supply LLC
For further assistance, please refer to the contact information provided at the point of purchase or on the manufacturer's official webojula.